    Cerebral microembolization during off-pump coronary artery bypass surgery with the Symmetry aortic connector device

    Get PDF
    ObjectiveThe use of aortic connector systems for proximal vein grafts in off-pump coronary artery bypass grafting might minimize aortic manipulation by eliminating the need for partial aortic clamping. The objective of this study was to asses whether use of a Symmetry connector (St Jude Medical, Inc, St Paul, Minn) reduced intraoperative cerebral embolization.MethodsThirty-two consecutive patients underwent off-pump coronary artery bypass grafting. Sixteen patients received at least one mechanical proximal vein graft anastomosis with a Symmetry aortic connector system. Sixteen patients representing the control group underwent operations with standard suturing techniques using partial aortic clamping. During surgical intervention, all patients were monitored continuously with multifrequency transcranial Doppler scanning, which detected and differentiated cerebral emboli.ResultsThere were significantly more cerebral emboli in the Symmetry group (median, 36) compared with the control group (median, 11; P = .027). This was due to a higher number of gaseous emboli in the Symmetry group than in the control group (median, 27 vs 8; P = .014), whereas there was no significant difference regarding the number of solid emboli (median, 7 vs 3; P = .139).ConclusionUse of a Symmetry connector system during proximal vein graft anastomosis increased the number of emboli to the brain compared with a standard technique in coronary bypass surgery without cardiopulmonary bypass

    The Scandinavian multicenter hemodynamic evaluation of the SJM Regent aortic valve

    Get PDF
    Background: 112 patients who received small and medium sized St.Jude Regent heart valves (19-25 mm) at 7 Scandinavian centers were studied between January 2003 and February 2005 to obtain non-invasive data regarding the hemodynamic performance at rest and during Dobutamine stress echocardiography (DSE) testing one year after surgery. Material and methods: 46 woman and 66 men, aged 61.8 +/- 9.7 (18-75) years, were operated on for aortic regurgitation (17), stenosis (65), or mixed dysfunction (30). Valve sizes were 19 mm (6), 21 mm (33), 23 mm (41), 25 mm (30). Two patients receiving size 27 valves were excluded from the hemodynamic evaluation. Pledgets were used in 100 patients, everted mattress in 66 and simple interrupted sutures in 21. Valve orientation varied and was dependent on the surgeons' choice. 34 patients (30.4%) underwent concomitant coronary artery surgery. Results: There were two early deaths (1.8%) and three late deaths, one because of pancreatic cancer. Late events during follow-up were: non structural dysfunction (1), bleeding (2), thromboembolism (2). At one year follow up 93% of the patients were in NYHA classes 1-2 versus 47.8% preoperatively. Dobutamine stress echocardiography (DSE) was performed in a total of 66 and maximal peak stress was reached in 61 patients. During DSE testing, the following statistically significant changes took place: Heart rate increased by 73.0%, cardiac output by 85.5%, left ventriclular ejection fraction by 19.6%, and maximal mean prosthetic transvalvular gradient by 133.8%, whereas the effective orifice area index did not change. Left ventricular mass fell during one year from 215 +/- 63 to 197 +/- 62 g (p < 0.05). Conclusion: The Dobutamine test induces a substantial stress, well suitable for echocardiographic assessment of prosthesis valve function and can be performed in the majority of the patients. The changes in pressure gradients add to the hemodynamic characteristics of the various valve sizes. In our patients the St. Jude Regent valve performed satisfactory at rest and under pharmacological stress situation

    Invited Commentary

    No full text

    The Scandinavian multicenter hemodynamic evaluation of the SJM Regent aortic valve

    No full text
    Abstract Background 112 patients who received small and medium sized St.Jude Regent heart valves (19-25 mm) at 7 Scandinavian centers were studied between January 2003 and February 2005 to obtain non-invasive data regarding the hemodynamic performance at rest and during Dobutamine stress echocardiography (DSE) testing one year after surgery. Material and methods 46 woman and 66 men, aged 61.8 ± 9.7 (18-75) years, were operated on for aortic regurgitation (17), stenosis (65), or mixed dysfunction (30). Valve sizes were 19 mm (6), 21 mm (33), 23 mm (41), 25 mm (30). Two patients receiving size 27 valves were excluded from the hemodynamic evaluation. Pledgets were used in 100 patients, everted mattress in 66 and simple interrupted sutures in 21. Valve orientation varied and was dependent on the surgeons' choice. 34 patients (30.4%) underwent concomitant coronary artery surgery. Results There were two early deaths (1.8%) and three late deaths, one because of pancreatic cancer. Late events during follow-up were: non structural dysfunction (1), bleeding (2), thromboembolism (2). At one year follow up 93% of the patients were in NYHA classes 1-2 versus 47.8% preoperatively. Dobutamine stress echocardiography (DSE) was performed in a total of 66 and maximal peak stress was reached in 61 patients. During DSE testing, the following statistically significant changes took place: Heart rate increased by 73.0%, cardiac output by 85.5%, left ventriclular ejection fraction by 19.6%, and maximal mean prosthetic transvalvular gradient by 133.8%, whereas the effective orifice area index did not change. Left ventricular mass fell during one year from 215 ± 63 to 197 ± 62 g (p Conclusion The Dobutamine test induces a substantial stress, well suitable for echocardiographic assessment of prosthesis valve function and can be performed in the majority of the patients. The changes in pressure gradients add to the hemodynamic characteristics of the various valve sizes. In our patients the St. Jude Regent valve performed satisfactory at rest and under pharmacological stress situation.</p

    Clinical and echocardiographic assessment of the Medtronic Advantage aortic valve prosthesis: the Scandinavian multicentre, prospective study

    No full text
    OBJECTIVE: The aim of this report is the prospective, multicentre evaluation of clinical results and haemodynamic performance of the Medtronic Advantage aortic valve prosthesis. METHODS: From April 2001 to June 2003, 166 patients (male:female 125:41; mean (SD) age 61.8 (11.8) years) received an aortic advantage valve prosthesis. Complete cumulative follow‐up was 242.7 patient‐years (maximum 3.2; mean 1.6 years). Postoperatively, patients underwent early (within 30 days) and 1 year transthoracic echocardiography. RESULTS: 30 day mortality was 2.4% (n = 4). Kaplan–Meier estimates of freedom from complications and linearised rates were as follows: 96.9 (1.6)% survival; 94.7 (1.3)% (2.06 patients/year) thrombo‐embolism; 99.4 (0.6)% (0.4 patients/year) bleeding; 98.8 (0.9)% (0.8 patients/year) non‐structural valve dysfunction; 98.8 (0.9)% (0.8 patients/year) reoperation. Valvular mean pressure gradients ranged from 16 (3) mm Hg for size 19 to 7 (2) mm Hg for size 27 and the corresponding effective orifice areas ranged from 1.2 (0.25) to 3.2 (0.66) cm(2). In all, left ventricular mass significantly decreased (p<0.001) and fractional shortening increased (p<0.001) from postoperative to 1 year echocardiography. CONCLUSIONS: Haemodynamic performance and early clinical results of Medtronic advantage in the aortic position were satisfactory and comparable with those of other bileaflet valves in current clinical use