21 research outputs found

    Topical Nasal Anesthesia in Flexible Bronchoscopy – A Cross-Over Comparison between Two Devices

    No full text
    <div><p>Introduction</p><p>Topical airway anesthesia is known to improve tolerance and patient satisfaction during flexible bronchoscopy (FB). Lidocaine is commonly used, delivered as an atomized spray. The current study assesses safety and patient satisfaction for nasal anesthesia of a new atomization device during outpatient bronchoscopy in lung transplant recipients.</p><p>Methods</p><p>Using a prospective, non-blinded, cross-over design, patients enrolled between 01-10-2014 and 24-11-2014 received 2% lidocaine using the standard reusable nasal atomizer (CRNA). Those enrolled between 25-11-2014 and 30-01-2015, received a disposable intranasal mucosal atomization device (DIMAD). After each procedure, the treating physician, their assistant and the patient independently rated side-effects and satisfaction, basing their responses on visual analogue scales (VAS). At their next scheduled bronchoscopy during the study period, patients then received the alternative atomizer. Written consent was obtained prior to the first bronchoscopy, and the study approved by the institutional ethics committee.</p><p>Results</p><p>Of the 252 patients enrolled between 01-10-2014 and 30-01-2015, 80 (32%) received both atomizers. Physicians reported better efficacy (p = 0.001) and fewer side effects (p< = 0.001) for DIMAD in patients exposed to both procedures. Among patients with one visit, physicians and their assistants reported improved efficacy (p = 0.018, p = 0.002) and fewer side effects (p< = 0.001, p = 0.029) for the disposable atomizer, whereas patients reported no difference in efficacy or side effects (p = 0.72 and p = 0.20). No severe adverse events were noted. The cost of the reusable device was 4.08€ per procedure, compared to 3.70€ for the disposable device.</p><p>Discussion</p><p>Topical nasal anesthesia via a disposable intranasal mucosal atomization device (DIMAD) offers comparable safety and patient comfort, compared to conventional reusable nasal atomizers (CRNA) in lung transplant recipients. Procedural costs were reduced by 0.34€ per procedure.</p><p>Trial Registration</p><p>clinicaltrials.gov <a href="https://clinicaltrials.gov/ct2/show/NCT02237651?term=NCT02237651&rank=1" target="_blank">NCT02237651</a></p></div

    DataSheet1_Qualitative and quantitative evaluation of computed tomography changes in adults with cystic fibrosis treated with elexacaftor-tezacaftor-ivacaftor: a retrospective observational study.docx

    No full text
    Introduction: The availability of highly effective triple cystic fibrosis transmembrane conductance regulator (CFTR) modulator combination therapy with elexacaftor–tezacaftor–ivacaftor (ETI) has improved pulmonary outcomes and quality of life of people with cystic fibrosis (pwCF). The aim of this study was to assess computed tomography (CT) changes under ETI visually with the Brody score and quantitatively with dedicated software, and to correlate CT measures with parameters of clinical response.Methods: Twenty two adult pwCF with two consecutive CT scans before and after ETI treatment initiation were retrospectively included. CT was assessed visually employing the Brody score and quantitatively by YACTA, a well-evaluated scientific software computing airway dimensions and lung parenchyma with wall percentage (WP), wall thickness (WT), lumen area (LA), bronchiectasis index (BI), lung volume and mean lung density (MLD) as parameters. Changes in CT metrics were evaluated and the visual and quantitative parameters were correlated with each other and with clinical changes in sweat chloride concentration, spirometry [percent predicted of forced expiratory volume in one second (ppFEV1)] and body mass index (BMI).Results: The mean (SD) Brody score improved with ETI [55 (12) vs. 38 (15); p 1 with the Brody score (r = −0.606, p = 0.003) and with WT (r = −0.538, p = 0.010).Discussion: Morphological treatment response to ETI can be assessed using the Brody score as well as quantitative CT parameters. Changes in CT correlated with clinical improvements. The quantitative analysis with YACTA proved to be an objective, reproducible and simple method for monitoring lung disease, particularly with regard to future interventional clinical trials.</p
    corecore