4 research outputs found

    Improving Appropriate Use of Antifungal Medications: The Role of an Over-the-Counter Vaginal pH Self-Test Device

    Get PDF
    Objectives: To determine whether patients can understand and use the vaginal pH device in the diagnosis of vaginitis. To compare whether vaginal pH readings determined by patients and healthcare providers are similar. To determine whether vaginalpHcan reduce inappropriate over-the-counter (OTC) antifungal medication use and improve the correct diagnosis of vaginitis. Methods: One hundred and fifty-one women indicated their belief about the cause of their vaginal infection, read the instructions of the vaginal pH device package insert, used the device and interpreted the findings. The patient interpretations were compared with results obtained by healthcare providers, blinded to patient findings. Results: Over 96% of patients stated that they could easily read the instructions, use the vaginal pH device and interpret the readings. They obtained the same readings as healthcare professionals (Kappa = 0.9). Restricting the use of OTC antifungal medications to those individuals with vaginitis symptoms and vaginal pH ≤ 4.5 significantly reduced inappropriate use by approximately 50%, Fisher's exact test,p-value = 0.018. Conversely, seeking healthcare provider assessment with vaginal pH > 4.5, leads to correct diagnosis of vaginitis. Conclusions: The vaginal pH device can be used as an OTC diagnostic tool by consumers when a vaginal infection is suspected. Vaginal pH readings would direct patients whether to purchase an antifungal medication or seek professional diagnosis from a healthcare provider. Understanding and use of this vaginal pH device could reduce inappropriate use of OTC antifungal medications by approximately 50% and improve the correct diagnosis of vaginitis

    The Reamer/Irrigator/Aspirator Reduces Femoral Canal Pressure in Simulated TKA

    No full text
    Inserting the femoral intramedullary alignment rod during total knee arthroplasty (TKA) can generate high intramedullary pressure, which increases the risk of intraoperative complications caused by fat embolism. Despite modifications to the surgical procedure, the best method to prevent this increase in pressure remains unknown. The reamer/irrigator/aspirator is a surgical instrument designed for use during femoral canal entry to increase the canal size and remove intramedullary fat and may prevent this pressure increase. We posed two hypotheses: (1) using the reamer/irrigator/aspirator system will result in lower maximum femoral intramedullary pressure than using only conventional instrumentation during the initial steps of a TKA; and (2) using the reamer/irrigator/aspirator system in the initial steps of TKA will result in a mean maximum intramedullary pressure less than 200 mm Hg. We simulated a TKA on 14 cadaveric femurs to compare the femoral intramedullary pressure using both methods. Considerable decreases in femoral intramedullary pressure of 86% proximally and 87% distally were obtained by using the reamer/irrigator/aspirator system. The mean maximum pressure using the reamer/irrigator/aspirator system was less than 200 mm Hg. Additional clinical studies are needed to confirm any reduction in complications using the reamer/irrigator/aspirator system
    corecore