3,359 research outputs found

    Flow Characteristics Around Step-Up Street Canyons with Various Building Aspect Ratios

    Get PDF
    We investigate the flow characteristics around step-up street canyons with various building aspect ratios (ratio of along-canyon building length to street-canyon width, and upwind building height to downwind building height) using a computational fluid dynamics (CFD) model. Simulated results are validated against experimental wind-tunnel results, with the CFD simulations conducted under the same building configurations as those in the wind-tunnel experiments. The CFD model reproduces the measured in-canyon vortex, rooftop recirculation zone above the downwind building, and stagnation point position reasonably well. We analyze the flow characteristics, focusing on the structural change of the in-canyon flows and the interaction between the in- and around-canyon flows with the increase of building-length ratio. The in-canyon flows undergo development and mature stages as the building-length ratio increases. In the development stage (i.e., small building-length ratios), the position of the primary vortex wanders, and the incoming flow closely follows both the upstream and downstream building sidewalls. As a result, increasing momentum transfer from the upper layer contributes to a momentum increase in the in-canyon region, and the vorticity in the in-canyon region also increases. In the mature stage (i.e., large building-length ratios), the primary vortex stabilizes in position, and the incoming flow no longer follows the building sidewalls. This causes momentum loss through the street-canyon lateral boundaries. As the building-length ratio increases, momentum transfer from the upper layer slightly decreases, and the reverse flow, updraft, and streamwise flow in the in-canyon region also slightly decrease, resulting in vorticity reduction

    Analysis of Building Energy Savings Potential for Metal Panel Curtain Wall Building by Reducing Thermal Bridges at Joints Between Panels

    Get PDF
    AbstractTo achieve national greenhouse gas reduction in the building sector, heating and cooling energy in buildings should be reduced. The government has strengthened regulations on insulation performance for building energy savings. However, the building envelope has various thermal bridges. In particular, a metal panel curtain wall comprises a number of thermal bridges at joints between the panels and the fixing units, thus degrading the overall thermal performance. To reduce building energy, it is necessary to reduce thermal bridges in building envelopes. This study aims to analyze the energy saving potential achieved by reducing thermal bridges. For this, the insulation performance and building energy needs of the existing and alternative metal panel curtain wall were evaluated. The alternative metal panel curtain wall that uses plastic molds at joints between panels and the thermally-broken brackets was suggested to reduce heat loss through thermal bridges. As results, the effective U-value of the alternative metal panel curtain wall was reduced by 72% compared with the existing metal panel curtain wall. In addition, annual heating energy needs of the alternative metal panel curtain wall building was reduced by 26%, and annual total energy needs was reduced by 6% because annual cooling energy needs of it slightly increased compared with the existing metal panel curtain wall. In conclusion, the alternative metal panel curtain wall considerably influenced the savings in building energy needs by reducing thermal bridges

    Empirical Validation of Heat Transfer Performance Simulation of Graphite/PCM Concrete Materials for Thermally Activated Building System

    Get PDF
    To increase the heat capacity in lightweight construction materials, a phase change material (PCM) can be introduced to building elements. A thermally activated building system (TABS) with graphite/PCM concrete hollow core slab is suggested as an energy-efficient technology to shift and reduce the peak thermal load in buildings. An evaluation of heat storage and dissipation characteristics of TABS in graphite/PCM concrete has been conducted using dynamic simulations, but empirical validation is necessary to acceptably predict the thermal behavior of graphite/PCM concrete. This study aimed to validate the thermal behavior of graphite/PCM concrete through a three-dimensional transient heat transfer simulation. The simulation results were compared to experimental results from previous studies of concrete and graphite/PCM concrete. The overall thermal behavior for both materials was found to be similar to experiment results. Limitations in the simulation modeling, which included determination of the indoor heat transfer coefficient, assumption of constant thermal conductivity with temperature, and assumption of specimen homogeneity, led to slight differences between the measured and simulated results

    Diagnostic Approaches for Idiopathic Pulmonary Fibrosis

    Get PDF
    Idiopathic pulmonary fibrosis (IPF) is a chronic, progressive, fibrosing interstitial pneumonia with a very poor prognosis. Accurate diagnosis of IPF is essential for good outcomes but remains a major medical challenge due to variability in clinical presentation and the shortcomings of existing diagnostic tests. Medical history collection is the first and most important step in the IPF diagnosis process; the clinical probability of IPF is high if the suspected patient is 60 years or older, male, and has a history of cigarette smoking. Systemic assessment for connective tissue disease is essential in the initial evaluation of patients with suspected IPF to identify potential causes of interstitial lung disease (ILD). Radiologic examination using high-resolution computed tomography plays a pivotal role in the evaluation of patients with ILD, and prone and expiratory computed tomography images can be considered. If additional tests such as surgical lung biopsy or transbronchial lung cryobiopsy are needed, transbronchial lung cryobiopsy should be considered as an alternative to surgical lung biopsy in medical centers with experience performing this procedure. Diagnosis through multidisciplinary discussion (MDD) is strongly recommended as MDD has become the cornerstone for diagnosis of IPF, and the scope of MDD has expanded to monitoring of disease progression and suggestion of appropriate treatment options

    Data-Reserved Periodic Diffusion LMS With Low Communication Cost Over Networks

    Get PDF
    In this paper, we analyze diffusion strategies in which all nodes attempt to estimate a common vector parameter for achieving distributed estimation in adaptive networks. Under diffusion strategies, each node essentially needs to share processed data with predefined neighbors. Although the use of internode communication has contributed significantly to improving convergence performance based on diffusion, such communications consume a huge quantity of power in data transmission. In developing low-power consumption diffusion strategies, it is very important to reduce the communication cost without significant degradation of convergence performance. For that purpose, we propose a data-reserved periodic diffusion least-mean-squares (LMS) algorithm in which each node updates and transmits an estimate periodically while reserving its measurement data even during non-update time. By applying these reserved data in an adaptation step at update time, the proposed algorithm mitigates the decline in convergence speed incurred by most conventional periodic schemes. For a period p, the total cost of communication is reduced to a factor of 1/p relative to the conventional adapt-then-combine (ATC) diffusion LMS algorithm. The loss of combination steps in this process leads naturally to a slight increase in the steady-state error as the period p increases, as is theoretically confirmed through mathematical analysis. We also prove an interesting property of the proposed algorithm, namely, that it suffers less degradation of the steady-state error than the conventional diffusion in a noisy communication environment. Experimental results show that the proposed algorithm outperforms related conventional algorithms and, in particular, outperforms ATC diffusion LMS over a network with noisy links.11Ysciescopu

    Cell-free synthesis of functional phospholipase A1 from Serratia sp.

    Get PDF
    Additional file 1: Figure S1 Gas chromatography analysis of sesame oil incubated with cell-free synthesized PLA1

    Performance Analysis On A Variable Capacity Swash Plate Compressor

    Get PDF
    A numerical study on the performance of a variable capacity swash plate compressor for an automotive air-conditioning system was carried out. The compressor under investigation had six cylinders and capacity regulation was made by changing the swash plate inclination angle. A numerical simulation program was made based on mathematical modelings on the swash plate dynamics, refrigerant states in various control volumes such as cylinders and crank room, and flows in the opening passages of electric control valve for crank room pressure control. The simulation results such as mass flow rate, compressor power consumption, cooling capacity and COP were compared with measurements within ±5% deviation over various operating conditions except at low operating speed such as idling condition. By using the simulation program, the effect of the crank room pressure on the swash plate inclination angle and the determination of the crank room pressure level by the electric control valve openings could be investigated
    corecore