4 research outputs found

    Use of a Dual Mobility Socket to Manage Total Hip Arthroplasty Instability

    No full text
    Unconstrained tripolar hip implants provide an additional bearing using a mobile polyethylene component between the prosthetic head and the outer metal shell. Such a design increases the effective head diameter and therefore is an attractive option in challenging situations of unstable total hip arthroplasties. We report our experience with 54 patients treated using this dual mobility implant in such situations. We ascertained its ability to restore and maintain stability, and examined component loosening and component failure. At a minimum followup of 2.2 years (mean, 4 years; range, 2.2–6.8 years), one hip had redislocated 2 months postoperatively and was managed successfully without reoperation by closed reduction with no additional dislocation. Two patients required revision of the implant because of dislocation at the inner bearing. Technical errors were responsible for these failures. Three patients had reoperations for deep infections. The postoperative radiographs at latest followup showed very satisfactory osseointegration of the acetabular component because no radiolucent line or osteolysis was reported. Use of this unconstrained tripolar design was successful in restoring and maintaining hip stability. We observed encouraging results at short-term followup regarding potential for loosening or mechanical failures

    Use of a dual mobility socket to manage total hip arthroplasty instability, Clinical Orthopaedics and Related Research 467

    No full text
    Abstract Unconstrained tripolar hip implants provide an additional bearing using a mobile polyethylene component between the prosthetic head and the outer metal shell. Such a design increases the effective head diameter and therefore is an attractive option in challenging situations of unstable total hip arthroplasties. We report our experience with 54 patients treated using this dual mobility implant in such situations. We ascertained its ability to restore and maintain stability, and examined component loosening and component failure. At a minimum followup of 2.2 years (mean, 4 years; range, 2.2-

    Cementless total hip arthroplasty in Paget’s disease of bone: a retrospective review

    No full text
    Paget’s disease of bone (PDB) is a localised chronic osteopathy leading to bone deformities, bone hypervascularity, structural weakness and altered joint biomechanics. The pelvis and upper femur are frequently involved, resulting in disabling hip disease, and total hip arthroplasty (THA) may be required. We performed a retrospective study on the management and the outcome of 39 uncemented hydroxyapatite fully-coated THA in patients with PDB of the hip. The follow-up averaged 79.4 months (range 24–194). Functional scores improved significantly and, using the Harris hip score, 84% of patients had an excellent clinical outcome at the latest follow-up. Despite one case of an uncemented acetabular component with probable loosening, no implant revision had been required at our latest follow-up. Signs of implant loosening were found to be significantly more frequent in patients with active disease. For this reason, we advocate the use of pre-operative medication with bisphosphonates to reduce disease activity. Another benefit of this treatment is the significant decrease of intra-operative blood loss. Provided the control of disease activity in the pre-operative period with bisphosphonates is achieved, good outcome of cementless THAs can be expected. Bisphosphonates reduced the risk of implant loosening and excessive intra-operative blood loss
    corecore