2 research outputs found

    Rosuvastatin to Prevent Vascular Events in Men and Women with Elevated C-Reactive Protein

    Get PDF
    Background: Increased levels of the inflammatory biomarker high-sensitivity C-reactive protein predict cardiovascular events. Since statins lower levels of high-sensitivity C-reactive protein as well as cholesterol, we hypothesized that people with elevated high-sensitivity C-reactive protein levels but without hyperlipidemia might benefit from statin treatment.Methods: We randomly assigned 17,802 apparently healthy men and women with low-density lipoprotein (LDL) cholesterol levels of less than 130 mg per deciliter (3.4 mmol per liter) and high-sensitivity C-reactive protein levels of 2.0 mg per liter or higher to rosuvastatin, 20 mg daily, or placebo and followed them for the occurrence of the combined primary end point of myocardial infarction, stroke, arterial revascularization, hospitalization for unstable angina, or death from cardiovascular causes.Results: the trial was stopped after a median follow-up of 1.9 years (maximum, 5.0). Rosuvastatin reduced LDL cholesterol levels by 50% and high-sensitivity C-reactive protein levels by 37%. the rates of the primary end point were 0.77 and 1.36 per 100 person-years of follow-up in the rosuvastatin and placebo groups, respectively (hazard ratio for rosuvastatin, 0.56; 95% confidence interval [CI], 0.46 to 0.69; P<0.00001), with corresponding rates of 0.17 and 0.37 for myocardial infarction (hazard ratio, 0.46; 95% CI, 0.30 to 0.70; P=0.0002), 0.18 and 0.34 for stroke (hazard ratio, 0.52; 95% CI, 0.34 to 0.79; P=0.002), 0.41 and 0.77 for revascularization or unstable angina (hazard ratio, 0.53; 95% CI, 0.40 to 0.70; P<0.00001), 0.45 and 0.85 for the combined end point of myocardial infarction, stroke, or death from cardiovascular causes (hazard ratio, 0.53; 95% CI, 0.40 to 0.69; P<0.00001), and 1.00 and 1.25 for death from any cause (hazard ratio, 0.80; 95% CI, 0.67 to 0.97; P=0.02). Consistent effects were observed in all subgroups evaluated. the rosuvastatin group did not have a significant increase in myopathy or cancer but did have a higher incidence of physician-reported diabetes.Conclusions: in this trial of apparently healthy persons without hyperlipidemia but with elevated high-sensitivity C-reactive protein levels, rosuvastatin significantly reduced the incidence of major cardiovascular events. (ClinicalTrials.gov number, NCT00239681.).AstraZenecaNovartisMerckAbbottRocheSanofi-AventisMerck-Schering-PloughIsisDade BehringVascular BiogenicsPfizerMerck FrosstResverlogixDupontAegerionArisaphKowaGenentechMartekReliantGenzymeGlaxoSmithKlineBoehringer IngelheimDiaDexusMedlogixAntheraBristol-Myers SquibbVIA PharmaceuticalsInterleukin GeneticsKowa Research InstituteTakedaBG MedicineOxford BiosciencesHarvard Univ, Sch Med, Brigham & Womens Hosp, Ctr Cardiovasc Dis Prevent, Boston, MA 02215 USAHarvard Univ, Sch Med, Brigham & Womens Hosp, Div Cardiovasc Med, Boston, MA 02215 USAUniversidade Federal de São Paulo, São Paulo, BrazilMcGill Univ, Ctr Hlth, Montreal, PQ, CanadaCornell Univ, Weill Cornell Med Coll, New York, NY 10021 USAUniv Amsterdam, Acad Med Ctr, Dept Vasc Med, NL-1105 AZ Amsterdam, NetherlandsUniv Ulm, Med Ctr, Ulm, GermanyHosp Cordoba, Cordoba, ArgentinaCopenhagen Univ Hosp, Herlev Hosp, Herlev, DenmarkUniv Glasgow, Glasgow, Lanark, ScotlandSt Lukes Episcopal Hosp, Texas Heart Inst, Houston, TX 77030 USAUniversidade Federal de São Paulo, São Paulo, BrazilWeb of Scienc

    Analysis and implementation of fractional-order chaotic system with standard components

    Get PDF
    This paper is devoted to the problem of uncertainty in fractional-order Chaotic systems implemented by means of standard electronic components. The fractional order element (FOE) is typically substituted by one complex impedance network containing a huge number of discrete resistors and capacitors. In order to balance the complexity and accuracy of the circuit, a sparse optimization based parameter selection method is proposed. The random error and the uncertainty of system implementation are analyzed through numerical simulations. The effectiveness of the method is verified by numerical and circuit simulations, tested experimentally with electronic circuit implementations. The simulations and experiments show that the proposed method reduces the order of circuit systems and finds a minimum number for the combination of commercially available standard components.This work was supported in part by the National Natural Science Foundation of China under Grant 61501385, in part by the National Nuclear Energy Development Project of State Administration for Science, Technology and Industry for National Defense, PRC under Grant 18zg6103, and in part by Sichuan Science and Technology Program under Grant 2018JY0522. We would like to thank Xinghua Feng for meaningful discussion.info:eu-repo/semantics/publishedVersio
    corecore