43 research outputs found
Contact lens rehabilitation following repaired corneal perforations
BACKGROUND: Visual outcome following repair of post-traumatic corneal perforation may not be optimal due to presence of irregular keratometric astigmatism. We performed a study to evaluate and compare rigid gas permeable contact lens and spectacles in visual rehabilitation following perforating corneal injuries. METHOD: Eyes that had undergone repair for corneal perforating injuries with or without lens aspiration were fitted rigid gas permeable contact lenses. The fitting pattern and the improvement in visual acuity by contact lens over spectacle correction were noted. RESULTS: Forty eyes of 40 patients that had undergone surgical repair of posttraumatic corneal perforations were fitted rigid gas permeable contact lenses for visual rehabilitation. Twenty-four eyes (60%) required aphakic contact lenses. The best corrected visual acuity (BCVA) of ≥ 6/18 in the snellen's acuity chart was seen in 10 (25%) eyes with spectacle correction and 37 (92.5%) eyes with the use of contact lens (p < 0.001). The best-corrected visual acuity with spectacles was 0.20 ± 0.13 while the same with contact lens was 0.58 ± 0.26. All the patients showed an improvement of ≥ 2 lines over spectacles in the snellen's acuity chart with contact lens. CONCLUSION: Rigid gas permeable contact lenses are better means of rehabilitation in eyes that have an irregular cornea due to scars caused by perforating corneal injuries
Knowledge synthesis of benefits and adverse effects of measles vaccination: the Lasbela balance sheet
<p>Abstract</p> <p>Background</p> <p>In preparation for a cluster-randomized controlled trial of a community intervention to increase the demand for measles vaccination in Lasbela district of Pakistan, a balance sheet summarized published evidence on benefits and possible adverse effects of measles vaccination.</p> <p>Methods</p> <p>The balance sheet listed: 1) major health conditions associated with measles; 2) the risk among the unvaccinated who contract measles; 3) the risk among the vaccinated; 4) the risk difference between vaccinated and unvaccinated; and 5) the likely net gain from vaccination for each condition.</p> <p>Results</p> <p>Two models revealed very different projections of net gain from measles vaccine. A Lasbela-specific combination of low period prevalence of measles among the unvaccinated, medium vaccination coverage and low vaccine efficacy rate, as revealed by the baseline survey, resulted in less-than-expected gains attributable to vaccination. Modelled on estimates where the vaccine had greater efficacy, the gains from vaccination would be more substantial.</p> <p>Conclusion</p> <p>Specific local conditions probably explain the low rates among the unvaccinated while the high vaccine failure rate is likely due to weaknesses in the vaccination delivery system. Community perception of these realities may have had some role in household decisions about whether to vaccinate, although the major discouraging factor was inadequate access. The balance sheet may be useful as a communication tool in other circumstances, applied to up-to-date local evidence.</p
Volcano explosion in the eye: Expulsive choroidal haemorrhage.
BACKGROUND: This video shows the dreaded complication of expulsive suprachoroidal haemorrhage in a penetrating keratoplasty . It teaches the various measures that help in preventing and managing the challenge peri-operatively. PURPOSE: This video is intended to sensitize the corneal surgeons about this rare complication using real-time surgical video and prepare them to face this challenge by demonstrating the preventive and mitigating strategies. SYNOPSIS: A patient who was suitably taken up for an autokeratoplasty had expulsive choroidal haemorrhage in the non-seeing eye. This complication was managed using glycerin-preserved donor corneal button. Further, the video discusses various pre-operative and intra-operative optimizations to avoid such a complication and mitigate the damage caused by it, should it ever happen during a surgery. HIGHLIGHTS: Expulsive choroidal haemorrhage can be a traumatizing event and one must be mentally prepared to manage it. Pre-operative high-risk factors should always be managed and intra-operative maneuvers performed to prevent the complication, as shown in the video. VIDEO LINK: https://youtu.be/s_ImBugPELw
Comparative evaluation of femtosecond laser-assisted cataract surgery and conventional phacoemulsification in white cataract
Jeewan S Titiyal, Manpreet Kaur, Archita Singh, Tarun Arora, Namrata Sharma Cornea, Cataract & Refractive Surgery Services, Dr Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India Purpose: To compare femtosecond laser-assisted capsulotomy with conventional manual capsulorhexis in cases of white cataract.Patients and methods: The prospective comparative study enrolled 80 eyes (80 patients) with white cataract that underwent either femtosecond laser-assisted cataract surgery (Group I, n=40) or conventional manual phacoemulsification (Group II, n=40) at a tertiary care ophthalmic institution. The groups were divided based on the patient’s choice and affordability of the procedure. Capsulotomy/capsulorhexis was evaluated in terms of size, circularity index (4Π [area/perimeter2]), intraocular lens coverage, and continuity. Each group was further subdivided based on the release of white milky fluid on initiation of the capsulotomy/capsulorhexis, and the “fluid” cases were compared with the “no-fluid” cases. The primary outcome measure was capsulotomy/capsulorhexis characteristics in the two groups. The secondary outcome measures were intraoperative phacoemulsification parameters, intraoperative complications, and postoperative visual acuity.Results: The size of the capsulotomy/capsulorhexis was 4.9±0.1 mm in Group I and 5.3±0.4 mm in Group II (P<0.001). Mean circularity index was 0.996±0.003 and 0.909±0.047 in Groups I and II, respectively (P<0.001). In Group I, free-floating circular capsulotomies were obtained in 52.5% (21/40) eyes; 37.5% (15/40) eyes had microadhesions; and 10% (4/40) eyes had incomplete capsulotomy in 1–2 clock hours. The incidence of residual adhesions was more in cases with release of white milky fluid (P=0.003). In Group II, a multistep capsulorhexis was performed in 70% (28/40) of the eyes. There was no difference in terms of visual outcomes and intraoperative complications.Conclusion: Femtosecond laser-assisted cataract surgery has the advantage of creating a circular and optimally sized capsulotomy in cases of white cataract. The release of white milky fluid during femtosecond laser delivery is the most important factor affecting the creation of a free-floating capsulotomy. Keywords: femtosecond laser-assisted cataract surgery, white cataract, conventional phacoemulsification, capsulorhexi
Comparative evaluation of toric intraocular lens alignment and visual quality with image-guided surgery and conventional three-step manual marking
Jeewan S Titiyal, Manpreet Kaur, Cijin P Jose, Ruchita Falera, Ashutosh Kinkar, Lalit MS Bageshwar Cornea, Cataract and Refractive Surgery Services, Dr Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India Purpose: To compare toric intraocular lens (IOL) alignment assisted by image-guided surgery or manual marking methods and its impact on visual quality. Patients and methods: This prospective comparative study enrolled 80 eyes with cataract and astigmatism ≥1.5 D to undergo phacoemulsification with toric IOL alignment by manual marking method using bubble marker (group I, n=40) or Callisto eye and Z align (group II, n=40). Postoperatively, accuracy of alignment and visual quality was assessed with a ray tracing aberrometer. Primary outcome measure was deviation from the target axis of implantation. Secondary outcome measures were visual quality and acuity. Follow-up was performed on postoperative days (PODs) 1 and 30. Results: Deviation from the target axis of implantation was significantly less in group II on PODs 1 and 30 (group I: 5.5°±3.3°, group II: 3.6°±2.6°; p=0.005). Postoperative refractive cylinder was -0.89±0.35 D in group I and -0.64±0.36 D in group II (p=0.003). Visual acuity was comparable between both the groups. Visual quality measured in terms of Strehl ratio (p<0.05) and modulation transfer function (MTF) (p<0.05) was significantly better in the image-guided surgery group. Significant negative correlation was observed between deviation from target axis and visual quality parameters (Strehl ratio and MTF) (p<0.05). Conclusion: Image-guided surgery allows precise alignment of toric IOL without need for reference marking. It is associated with superior visual quality which correlates with the precision of IOL alignment. Keywords: toric IOL alignment, image-guided surgery, manual marking toric IOL, Callisto eye and Z align toric IOL, visual quality toric IOL, visual quality image-guided surger
Comparative evaluation of efficacy and safety of ophthalmic viscosurgical devices in phacoemulsification [ISRCTN34957881].
BACKGROUND: Various ophthalmic viscosurgical devices (OVD) are used to perform phacoemulsification and other intraocular surgeries. We performed a study to compare the efficacy and safety of three ophthalmic viscosurgical devices that are routinely used in phacoemulsification. METHODS: Fifty-six patients of immature senile cataract with hard nucleus (grade 3 and 4) who underwent phacoemulsification were included. Depending upon the type of OVD, patients were randomly allocated into three groups; group 1 (n = 19), Viscoat was used; group 2 (n = 19), Healon GV was used; group 3 (n = 18), Healon 5 was used. Parameters evaluated were uncorrected and best corrected visual acuity, specular microscopy, intraocular pressure and pachymetry both preoperatively and postoperatively on day 1, 1 week, 1 month and 3 months and development of any complication both intraoperative and postoperative were also noted. RESULTS: The mean increase in central corneal thickness was 15.17% (group 1); 17.26% (group 2) and 16.21% (group 3) on first postoperative day and was comparable in the three groups. The density of endothelial cells decreased postoperatively (day 1) by 12.54% (group 1), 13.76% (group 2) and 13.06% (group 3) and was comparable. The mean preoperative intraocular pressure in groups 1, 2 and 3 were 13.3 +/- 2.0, 14.0 +/- 2.2 and 13.2 +/- 3.2 mmHg respectively, which changed to 16.0 +/- 4.7, 12.2 +/- 4.7 and 12.3 +/- 4.8 respectively on first postoperative day and the change in intraocular pressure was significantly higher in group 1 (1 vs 2 & 1 vs 3; p = 0.02; oneway ANOVA). CONCLUSION: Viscoat, Healon GV and Healon 5 give comparable results in terms of efficacy and safety in performing phacoemulsification
Small incision lenticule extraction (SMILE) techniques: patient selection and perspectives
Jeewan S Titiyal, Manpreet Kaur, Farin Shaikh, Meghal Gagrani, Anand Singh Brar, Anubha Rathi Cornea, Cataract and Refractive Surgery Services, Dr Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India Abstract: Refractive lenticule extraction is becoming the procedure of choice for the management of myopia and myopic astigmatism owing to its precision, biomechanical stability, and better ocular surface. It has similar safety, efficacy, and predictability as femtosecond laser-assisted in situ keratomileusis (FS-LASIK) and is associated with better patient satisfaction. The conventional technique of small incision lenticule extraction (SMILE) involves docking, femtosecond laser application, lenticule dissection from the surrounding stroma, and extraction. It has a steep learning curve compared to conventional flap-based corneal ablative procedures, and the surgical technique may be challenging especially for a novice surgeon. As SMILE is gaining worldwide acceptance among refractive surgeons, different modifications of the surgical technique have been described to ease the process of lenticule extraction and minimize complications. Good patient selection is essential to ensure optimal patient satisfaction, and novice surgeons should avoid cases with low myopia (thin refractive lenticules), difficult orbital anatomy, high astigmatism, or uncooperative, anxious patients to minimize complications. A comprehensive MEDLINE search was performed using “small incision lenticule extraction,” “SMILE,” and “refractive lenticule extraction” as keywords, and we herein review the patient selection for SMILE and various surgical techniques of SMILE with their pros and cons. With increasing surgeon experience, a standard technique is expected to evolve that may be performed in all types of cases with optimal outcomes and minimal adverse effects. Keywords: refractive lenticule extraction, femtosecond-laser assisted lenticule extraction, SMILE techniques, refractive surger
Indications and outcome of repeat penetrating keratoplasty in India.
BACKGROUND: Repeat penetrating keratoplasty is quite often required as there is high chance of failure of the primary graft particularly in the developing world. We planned a study to analyze the indications and outcome of repeat penetrating keratoplasty in a tertiary care centre in India. METHODS: A retrospective analysis of all the patients who underwent repeat penetrating keratoplasty, between January 1999 and December 2001 was performed. The parameters evaluated were indication for the primary penetrating keratoplasty, causes of failure of the previous graft, and final visual outcome and clarity of the repeat corneal grafts. RESULTS: Of fifty-three eyes of 50 patients with repeat penetrating keratoplasty (three patients underwent bilateral corneal regrafts), 37 eyes had undergone one regraft each, 14 eyes two regrafts and two eyes had three regrafts. The follow-up of the patients ranged from one to three years. The most common primary etiologic diagnosis was vascularized corneal scars (66%), of which the scars related to infection were most common (68.5%). Twenty-eight regrafts (52.8%) remained clear at a mean follow-up of 1.54 +/- 0.68 years, of which 25 were single regrafts (89.3%). The commonest cause of failure of regraft was infection to the corneal graft (recurrence of herpetic infection in 9 eyes and perforated graft ulcers in 3 eyes). Three (18.6%) of the 16 eyes with multiple corneal regrafts achieved a BCVA of 6/60. Overall, only five eyes (all with single regraft) achieved a BCVA of 6/18 or better at the end of follow-up. CONCLUSION: Graft infection is the leading cause of failure of repeat keratoplasty in this part of the world. Prognosis for visual recovery and graft survival is worse in eyes undergoing multiple regrafts
Comparison of visual performance and after cataract formation between two monofocal aspheric intraocular lenses following phacoemulsification for senile cataract: A randomized controlled study
PURPOSE: Monofocal aspheric intraocular lenses (IOLs) provide better visual outcome compared to other available IOLs following cataract surgery. However, the imported IOLs are expensive and are not affordable by all subset of patients in low- to middle-income countries like India. The aim of this study is to compare the safety and efficacy of a relatively low cost indigenous IOL (Acriol EC) with an imported aspheric IOL (AcrySof IQ). METHODS: A randomized controlled trial was conducted at a tertiary care centre. Two hundred and five eyes of 137 patients >45 years of age with uncomplicated age-related cataract were recruited. All cases underwent standard phacoemulsification and randomly assigned to one of the IOL implantations (Group I: AcrySof IOL; Group II: Acriol EC IOL). Primary outcome measure was best-corrected visual acuity (BCVA). Secondary outcomes included visual function (VF) score, spherical equivalent, contrast sensitivity, optical aberrations, and posterior capsular opacification. Independent t-test to compare two means; Mann-Whitney test; Pearson's Chi-square test, and McNemar's test were used for analyzing the nonparametric data such as incidence of posterior capsule opacification. RESULTS: There was no significant difference in the mean postoperative BCVA at 1, 3, 6, and 12 months in either group (P > 0.05). The contrast sensitivity, wavefront aberrations, VF score, and posterior capsular opacification were comparable between the groups except for higher-order aberrations and spherical aberration, which were higher in Group II. CONCLUSIONS: Acriol EC IOL provides visual outcomes comparable to other commonly used aspheric IOLs with comparable safety and efficacy at an affordable cost
