90 research outputs found
A proposed testbed for detector tomography
Measurement is the only part of a general quantum system that has yet to be
characterized experimentally in a complete manner. Detector tomography provides
a procedure for doing just this; an arbitrary measurement device can be fully
characterized, and thus calibrated, in a systematic way without access to its
components or its design. The result is a reconstructed POVM containing the
measurement operators associated with each measurement outcome. We consider two
detectors, a single-photon detector and a photon-number counter, and propose an
easily realized experimental apparatus to perform detector tomography on them.
We also present a method of visualizing the resulting measurement operators.Comment: 9 pages, 4 figure
Mapping coherence in measurement via full quantum tomography of a hybrid optical detector
Quantum states and measurements exhibit wave-like --- continuous, or
particle-like --- discrete, character. Hybrid discrete-continuous photonic
systems are key to investigating fundamental quantum phenomena, generating
superpositions of macroscopic states, and form essential resources for
quantum-enhanced applications, e.g. entanglement distillation and quantum
computation, as well as highly efficient optical telecommunications. Realizing
the full potential of these hybrid systems requires quantum-optical
measurements sensitive to complementary observables such as field quadrature
amplitude and photon number. However, a thorough understanding of the practical
performance of an optical detector interpolating between these two regions is
absent. Here, we report the implementation of full quantum detector tomography,
enabling the characterization of the simultaneous wave and photon-number
sensitivities of quantum-optical detectors. This yields the largest
parametrization to-date in quantum tomography experiments, requiring the
development of novel theoretical tools. Our results reveal the role of
coherence in quantum measurements and demonstrate the tunability of hybrid
quantum-optical detectors.Comment: 7 pages, 3 figure
Testing sequential quantum measurements: how can maximal knowledge be extracted?
The extraction of information from a quantum system unavoidably implies a
modification of the measured system itself. It has been demonstrated recently
that partial measurements can be carried out in order to extract only a portion
of the information encoded in a quantum system, at the cost of inducing a
limited amount of disturbance. Here we analyze experimentally the dynamics of
sequential partial measurements carried out on a quantum system, focusing on
the trade-off between the maximal information extractable and the disturbance.
In particular we consider two different regimes of measurement, demonstrating
that, by exploiting an adaptive strategy, an optimal trade-off between the two
quantities can be found, as observed in a single measurement process. Such
experimental result, achieved for two sequential measurements, can be extended
to N measurement processes.Comment: 5 pages, 3 figure
Measuring measurement
Measurement connects the world of quantum phenomena to the world of classical
events. It plays both a passive role, observing quantum systems, and an active
one, preparing quantum states and controlling them. Surprisingly - in the light
of the central status of measurement in quantum mechanics - there is no general
recipe for designing a detector that measures a given observable. Compounding
this, the characterization of existing detectors is typically based on partial
calibrations or elaborate models. Thus, experimental specification (i.e.
tomography) of a detector is of fundamental and practical importance. Here, we
present the realization of quantum detector tomography: we identify the optimal
positive-operator-valued measure describing the detector, with no ancillary
assumptions. This result completes the triad, state, process, and detector
tomography, required to fully specify an experiment. We characterize an
avalanche photodiode and a photon number resolving detector capable of
detecting up to eight photons. This creates a new set of tools for accurately
detecting and preparing non-classical light.Comment: 6 pages, 4 figures,see video abstract at
http://www.quantiki.org/video_abstracts/0807244
Using coherence to enhance function in chemical and biophysical systems
Coherence phenomena arise from interference, or the addition, of wave-like amplitudes with fixed phase differences. Although coherence has been shown to yield transformative ways for improving function, advances have been confined to pristine matter and coherence was considered fragile. However, recent evidence of coherence in chemical and biological systems suggests that the phenomena are robust and can survive in the face of disorder and noise. Here we survey the state of recent discoveries, present viewpoints that suggest that coherence can be used in complex chemical systems, and discuss the role of coherence as a design element in realizing function
Principles of Hand Fracture Management
The hand is essential in humans for physical manipulation of their surrounding environment. Allowing the ability to grasp, and differentiated from other animals by an opposing thumb, the main functions include both fine and gross motor skills as well as being a key tool for sensing and understanding the immediate surroundings of their owner
Treatment of osteochondral lesions of the talus: a systematic review
The aim of this study was to summarize all eligible studies to compare the effectiveness of treatment strategies for osteochondral defects (OCD) of the talus. Electronic databases from January 1966 to December 2006 were systematically screened. The proportion of the patient population treated successfully was noted, and percentages were calculated. For each treatment strategy, study size weighted success rates were calculated. Fifty-two studies described the results of 65 treatment groups of treatment strategies for OCD of the talus. One randomized clinical trial was identified. Seven studies described the results of non-operative treatment, 4 of excision, 13 of excision and curettage, 18 of excision, curettage and bone marrow stimulation (BMS), 4 of an autogenous bone graft, 2 of transmalleolar drilling (TMD), 9 of osteochondral transplantation (OATS), 4 of autologous chondrocyte implantation (ACI), 3 of retrograde drilling and 1 of fixation. OATS, BMS and ACI scored success rates of 87, 85 and 76%, respectively. Retrograde drilling and fixation scored 88 and 89%, respectively. Together with the newer techniques OATS and ACI, BMS was identified as an effective treatment strategy for OCD of the talus. Because of the relatively high cost of ACI and the knee morbidity seen in OATS, we conclude that BMS is the treatment of choice for primary osteochondral talar lesions. However, due to great diversity in the articles and variability in treatment results, no definitive conclusions can be drawn. Further sufficiently powered, randomized clinical trials with uniform methodology and validated outcome measures should be initiated to compare the outcome of surgical strategies for OCD of the talus
Ir-LBP, an Ixodes ricinus Tick Salivary LTB4-Binding Lipocalin, Interferes with Host Neutrophil Function
BACKGROUND: During their blood meal, ticks secrete a wide variety of proteins that can interfere with their host's defense mechanisms. Among these proteins, lipocalins play a major role in the modulation of the inflammatory response. METHODOLOGY/PRINCIPAL FINDINGS: We previously identified 14 new lipocalin genes in the tick Ixodes ricinus. One of them codes for a protein that specifically binds leukotriene B4 with a very high affinity (Kd: +/-1 nM), similar to that of the neutrophil transmembrane receptor BLT1. By in silico approaches, we modeled the 3D structure of the protein and the binding of LTB4 into the ligand pocket. This protein, called Ir-LBP, inhibits neutrophil chemotaxis in vitro and delays LTB4-induced apoptosis. Ir-LBP also inhibits the host inflammatory response in vivo by decreasing the number and activation of neutrophils located at the tick bite site. Thus, Ir-LBP participates in the tick's ability to interfere with proper neutrophil function in inflammation. CONCLUSIONS/SIGNIFICANCE: These elements suggest that Ir-LBP is a "scavenger" of LTB4, which, in combination with other factors, such as histamine-binding proteins or proteins inhibiting the classical or alternative complement pathways, permits the tick to properly manage its blood meal. Moreover, with regard to its properties, Ir-LBP could possibly be used as a therapeutic tool for illnesses associated with an increased LTB4 production.Journal ArticleResearch Support, Non-U.S. Gov'tSCOPUS: ar.jinfo:eu-repo/semantics/publishe
An experimental test of noncontextuality without unphysical idealizations
To make precise the sense in which nature fails to respect classical physics, one requires a formal notion of classicality. Ideally, such a notion should be defined operationally, so that it can be subject to direct experimental test, and it should be applicable in a wide variety of experimental scenarios so that it can cover the breadth of phenomena thought to defy classical understanding. Bell’s notion of local causality fulfils the first criterion but not the second. The notion of noncontextuality fulfils the second criterion, but it is a long-standing question whether it can be made to fulfil the first. Previous attempts to test noncontextuality have all assumed idealizations that real experiments cannot achieve, namely noiseless measurements and exact operational equivalences. Here we show how to devise tests that are free of these idealizations. We perform a photonic implementation of one such test, ruling out noncontextual models with high confidence
A characterization of the single-photon sensitivity of an electron multiplying charge-coupled device
We experimentally characterize the performance of the electron multiplying charge-coupled device (EMCCD) camera for the detection of single photons. The tests are done with the photon pairs generated from parametric downconversion (PDC). The gain, time response and noise performance of the EMCCD are characterized. In addition, we attempt to use the camera to measure the spatial correlations of PDC. The results reveal the capabilities and limits of the EMCCD as a single-photon-detector array for the applications of quantum optics, astronomy and microscopy. © 2009 IOP Publishing Ltd
- …