14 research outputs found

    Analysis of aortic valve commissural fusion after support with continuous-flow left ventricular assist device

    No full text
    Continuous-flow left ventricular assist devices (cf-LVADs) may induce commissural fusion of the aortic valve leaflets. Factors associated with this occurrence of commissural fusion are unknown. The aim of this study was to examine histological characteristics of cf-LVAD-induced commissural fusion in relation to clinical variables. Gross and histopathological examinations were performed on 19 hearts from patients supported by either HeartMate II (n = 17) or HeartWare (n = 2) cf-LVADs and related to clinical characteristics (14 heart transplantation, 5 autopsy). Eleven of the 19 (58%) aortic valves showed fusion of single or multiple commissures (total fusion length 11 mm [4-20] (median [interquartile range]) per valve), some leading to noticeable nodular displacements or considerable lumen diameter narrowing. Multiple fenestrations were observed in one valve. Histopathological examination confirmed commissural fusion, with varying changes in valve layer structure without evidence of inflammatory infiltration at the site of fusion. Commissural fusion wa Aortic valve commissural fusion after support with cf-LVADs is a non-inflammatory process leading to changes in valve layer structure that can be observed in > 50% of cf-LVAD patients. This is the first study showing that patients receiving full cf-LVAD support without opening of the valve have a significantly higher risk of developing commissural fusion than patients on partial support

    Guidelines for heart transplantation

    No full text
    Based on the changes in the field of heart transplantation and the treatment and prognosis of patients with heart failure, these updated guidelines were composed by a committee under the supervision of both the Netherlands Society of Cardiology and the Netherlands Association for Cardiothoracic surgery (NVVC and NVT). The indication for heart transplantation is defined as: 'End-stage heart disease not remediable by more conservative measures'. Contraindications are: irreversible pulmonary hypertension/elevated pulmonary vascular resistance; active systemic infection; active malignancy or history of malignancy with probability of recurrence; inability to comply with complex medical regimen; severe peripheral or cerebrovascular disease and irreversible dysfunction of another organ, including diseases that may limit prognosis after heart transplantation. Considering the difficulties in defining end-stage heart failure, estimating prognosis in the individual patient and the continuing evolution of available therapies, the present criteria are broadly defined. The final acceptance is done by the transplant team which has extensive knowledge of the treatment of patients with advanced heart failure on the one hand and thorough experience with heart transplantation and mechanical circulatory support on the other hand

    ReliantHeart: Forward Compatibility and TET

    No full text
    ReliantHeart (ReliantHeart Inc., Houston, TX, USA) HeartAssist5 (HA5) left ventricular assist device (LVAD) system is a miniaturized, implantable, second- generation axial-flow pump capable of longterm circulatory support in patients with end-stage heart failure. The device results to be the first continuous- flow LVAD ever implanted in human being. This compact axial-flow pump has been in development since 1988 named as MicroMed DeBakey [1] (MicroMed Cardiovascular Inc., Houston, TX, USA) whose design belongs to the second-generation pump category [2, 3]
    corecore