71 research outputs found

    Duke Surgery Patient Safety: an open-source application for anonymous reporting of adverse and near-miss surgical events

    Get PDF
    BACKGROUND: Studies have shown that 4% of hospitalized patients suffer from an adverse event caused by the medical treatment administered. Some institutions have created systems to encourage medical workers to report these adverse events. However, these systems often prove to be inadequate and/or ineffective for reviewing the data collected and improving the outcomes in patient safety. OBJECTIVE: To describe the Web-application Duke Surgery Patient Safety, designed for the anonymous reporting of adverse and near-miss events as well as scheduled reporting to surgeons and hospital administration. SOFTWARE ARCHITECTURE: DSPS was developed primarily using Java language running on a Tomcat server and with MySQL database as its backend. RESULTS: Formal and field usability tests were used to aid in development of DSPS. Extensive experience with DSPS at our institution indicate that DSPS is easy to learn and use, has good speed, provides needed functionality, and is well received by both adverse-event reporters and administrators. DISCUSSION: This is the first description of an open-source application for reporting patient safety, which allows the distribution of the application to other institutions in addition for its ability to adapt to the needs of different departments. DSPS provides a mechanism for anonymous reporting of adverse events and helps to administer Patient Safety initiatives. CONCLUSION: The modifiable framework of DSPS allows adherence to evolving national data standards. The open-source design of DSPS permits surgical departments with existing reporting mechanisms to integrate them with DSPS. The DSPS application is distributed under the GNU General Public License

    Extracellular Heat Shock Protein (Hsp)70 and Hsp90α Assist in Matrix Metalloproteinase-2 Activation and Breast Cancer Cell Migration and Invasion

    Get PDF
    Breast cancer is second only to lung cancer in cancer-related deaths in women, and the majority of these deaths are caused by metastases. Obtaining a better understanding of migration and invasion, two early steps in metastasis, is critical for the development of treatments that inhibit breast cancer metastasis. In a functional proteomic screen for proteins required for invasion, extracellular heat shock protein 90 alpha (Hsp90α) was identified and shown to activate matrix metalloproteinase 2 (MMP-2). The mechanism of MMP-2 activation by Hsp90α is unknown. Intracellular Hsp90α commonly functions with a complex of co-chaperones, leading to our hypothesis that Hsp90α functions similarly outside of the cell. In this study, we show that a complex of co-chaperones outside of breast cancer cells assists Hsp90α mediated activation of MMP-2. We demonstrate that the co-chaperones Hsp70, Hop, Hsp40, and p23 are present outside of breast cancer cells and co-immunoprecipitate with Hsp90α in vitro and in breast cancer conditioned media. These co-chaperones also increase the association of Hsp90α and MMP-2 in vitro. This co-chaperone complex enhances Hsp90α-mediated activation of MMP-2 in vitro, while inhibition of Hsp70 in conditioned media reduces this activation and decreases cancer cell migration and invasion. Together, these findings support a model in which MMP-2 activation by an extracellular co-chaperone complex mediated by Hsp90α increases breast cancer cell migration and invasion. Our studies provide insight into a novel pathway for MMP-2 activation and suggest Hsp70 as an additional extracellular target for anti-metastatic drug development

    The use of implantable cardioverter defibrillators in Iceland: a retrospective population based study

    Get PDF
    BACKGROUND: Indications for implantable cardioverter defibrillator (ICD) implantation have expanded considerably in recent years, resulting in steadily growing numbers of ICD recipients worldwide. The aim of this study was to review the overall experience with ICDs in Iceland. METHODS: This was a retrospective single centre study set at the University Hospital in Iceland. Data on all ICD implantations in Iceland from the first implantation in 1992 till the end of 2002 was reviewed. RESULTS: Sixty-two patients (71% male) received an ICD during this period. There was an increase in the number of implants by year and the number of new implants in 2001 and 2002 amounted to 56 and 38 per million, respectively. The mean age at implantation was 58 (+/-14) years. Forty patients (65%) had coronary artery disease. The most common indications for ICD implantation were cardiac arrest, 32 (52%) and another 26 (42%) had experienced ventricular tachycardia without cardiac arrest. The most common adverse event was inappropriate shocks. Twenty-eight patients (45%) received therapy from their ICDs, with the majority receiving appropriate therapy. Of the thirteen patients deceased before or during the study period, no case of sudden arrhythmic death was observed. CONCLUSION: This study shows that the experience with ICDs in Iceland is in most respects similar to other Western countries

    Matrix metalloproteinases and genetic mouse models in cancer research: a mini-review

    Get PDF
    • …
    corecore