18 research outputs found

    VITA-D: Cholecalciferol substitution in vitamin D deficient kidney transplant recipients: A randomized, placebo-controlled study to evaluate the post-transplant outcome

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Vitamin D does not only regulate calcium homeostasis but also plays an important role as an immune modulator. It influences the immune system through the induction of immune shifts and regulatory cells resulting in immunologic tolerance. As such, vitamin D is thought to exert beneficial effects within the transplant setting, especially in kidney transplant recipients, considering the high prevalence of vitamin D deficiency in kidney transplant recipients.</p> <p>Methods/Design</p> <p>The VITA-D study, a randomized, placebo-controlled, double-blind study with two parallel groups including a total of 200 kidney transplant recipients, is designed to investigate the immunomodulatory and renoprotective effects of cholecalciferol (vitamin D<sub>3</sub>) within the transplant setting. Kidney transplant recipients found to have vitamin D deficiency defined as 25-hydroxyvitamin D<sub>3 </sub>< 50 nmol per liter will be randomly assigned to receive either oral cholecalciferol therapy or placebo and will be followed for one year. Cholecalciferol will be administered at a dose of 6800 International Units daily over a time period of one year.</p> <p>The objective is to evaluate the influence of vitamin D<sub>3 </sub>substitution in vitamin D deficient kidney transplant recipients on the post-transplant outcome. As a primary endpoint glomerular filtration rate calculated with the MDRD formula (modification of diet in renal disease) one year after kidney transplantation will be evaluated. Incidence of acute rejection episodes, and the number and severity of infections (analyzed by means of C-reactive protein) within the first year after transplantation will be monitored as well. As a secondary endpoint the influence of vitamin D<sub>3 </sub>on bone mineral density within the first year post-transplant will be assessed. Three DXA analyses will be performed, one within the first four weeks post-transplant, one five months and one twelve months after kidney transplantation.</p> <p>Trial Registration</p> <p>ClinicalTrials.gov NCT00752401</p

    Tibial or hip BMD predict clinical fracture risk equally well: results from a prospective study in 700 elderly Swiss women.

    Get PDF
    SUMMARY: In a randomly selected cohort of Swiss community-dwelling elderly women prospectively followed up for 2.8 +/- 0.6 years, clinical fractures were assessed twice yearly. Bone mineral density (BMD) measured at tibial diaphysis (T-DIA) and tibial epiphysis (T-EPI) using dual-energy X-ray absorptiometry (DXA) was shown to be a valid alternative to lumbar spine or hip BMD in predicting fractures. INTRODUCTION: A study was carried out to determine whether BMD measurement at the distal tibia sites of T-EPI and T-DIA is predictive of clinical fracture risk. METHODS: In a predefined representative cohort of Swiss community-dwelling elderly women aged 70-80 years included in the prospective, multi-centre Swiss Evaluation of the Methods of Measurement of Osteoporotic Fracture risk (SEMOF) study, fracture risk profile was assessed and BMD measured at the lumbar spine (LS), hip (HIP) and tibia (T-DIA and T-EPI) using DXA. Thereafter, clinical fractures were reported in a bi-yearly questionnaire. RESULTS: During 1,786 women-years of follow-up, 68 clinical fragility fractures occurred in 61 women. Older age and previous fracture were identified as risk factors for the present fractures. A decrease of 1 standard deviation in BMD values yielded a 1.5-fold (HIP) to 1.8-fold (T-EPI) significant increase in clinical fragility fracture hazard ratio (adjusted for age and previous fracture). All measured sites had comparable performance for fracture prediction (area under the curve range from 0.63 [LS] to 0.68 [T-EPI]). CONCLUSION: Fracture risk prediction with BMD measurements at T-DIA and T-EPI is a valid alternative to BMD measurements at LS or HIP for patients in whom these sites cannot be accessed for clinical, technical or practical reasons

    Reliability of Phase Velocity Measurements of Flexural Acoustic Waves in the Human Tibia In-Vivo

    No full text
    Axial-transmission acoustics have shown to be a promising technique to measure individual bone properties and detect bone pathologies. With the ultimate goal being the in-vivo application of such systems, quantification of the key aspects governing the reliability is crucial to bring this method towards clinical use.This work presents a systematic reliability study quantifying the sources of variability and their magnitudes of in-vivo measurements using axial-transmission acoustics. 42 healthy subjects were measured by an experienced operator twice per week, over a four-month period, resulting in over 150000 wave measurements. In a complementary study to assess the influence of different operators performing the measurements, 10 novice operators were trained, and each measured 5 subjects on a single occasion, using the same measurement protocol as in the first part of the study.The estimated standard error for the measurement protocol used to collect the study data was ∼ 17 m/s (∼ 4% of the grand mean) and the index of dependability, as a measure of reliability, was Φ = 0.81. It was shown that the method is suitable for multi-operator use and that the reliability can be improved efficiently by additional measurements with device repositioning, while additional measurements without repositioning cannot improve the reliability substantially. Phase velocity values were found to be significantly higher in males than in females (p < 10-5) and an intra-class correlation coefficient of r = 0.70 was found between the legs of each subject.The high reliability of this non-invasive approach and its intrinsic sensitivity to mechanical properties opens perspectives for the rapid and inexpensive clinical assessment of bone pathologies, as well as for monitoring programmes without any radiation exposure for the patient

    Risks and benefits of percutaneous vertebroplasty or kyphoplasty in the management of osteoporotic vertebral fractures.

    Get PDF
    Vertebral fracture (VF) is the most common osteoporotic fracture and is associated with high morbidity and mortality. Conservative treatment combining antalgic agents and rest is usually recommended for symptomatic VFs. The aim of this paper is to review the randomized controlled trials comparing the efficacy and safety of percutaneous vertebroplasty (VP) and percutaneous balloon kyphoplasty (KP) versus conservative treatment. VP and KP procedures are associated with an acceptable general safety. Although the case series investigating VP/KP have all shown an outstanding analgesic benefit, randomized controlled studies are rare and have yielded contradictory results. In several of these studies, a short-term analgesic benefit was observed, except in the prospective randomized sham-controlled studies. A long-term analgesic and functional benefit has rarely been noted. Several recent studies have shown that both VP and KP are associated with an increased risk of new VFs. These fractures are mostly VFs adjacent to the procedure, and they occur within a shorter time period than VFs in other locations. The main risk factors include the number of preexisting VFs, the number of VPs/KPs performed, age, decreased bone mineral density, and intradiscal cement leakage. It is therefore important to involve the patients to whom VP/KP is being proposed in the decision-making process. It is also essential to rapidly initiate a specific osteoporosis therapy when a VF occurs (ideally a bone anabolic treatment) so as to reduce the risk of fracture. Randomized controlled studies are necessary in order to better define the profile of patients who likely benefit the most from VP/KP
    corecore