234 research outputs found

    Virtual Biopsy in Soft Tissue Sarcoma. How Close Are We?

    Get PDF
    A shift in radiology to a data-driven specialty has been unlocked by synergistic developments in imaging biomarkers (IB) and computational science. This is advancing the capability to deliver "virtual biopsies" within oncology. The ability to non-invasively probe tumour biology both spatially and temporally would fulfil the potential of imaging to inform management of complex tumours; improving diagnostic accuracy, providing new insights into inter- and intra-tumoral heterogeneity and individualised treatment planning and monitoring. Soft tissue sarcomas (STS) are rare tumours of mesenchymal origin with over 150 histological subtypes and notorious heterogeneity. The combination of inter- and intra-tumoural heterogeneity and the rarity of the disease remain major barriers to effective treatments. We provide an overview of the process of successful IB development, the key imaging and computational advancements in STS including quantitative magnetic resonance imaging, radiomics and artificial intelligence, and the studies to date that have explored the potential biological surrogates to imaging metrics. We discuss the promising future directions of IBs in STS and illustrate how the routine clinical implementation of a virtual biopsy has the potential to revolutionise the management of this group of complex cancers and improve clinical outcomes

    A framework for optimization of diffusion-weighted MRI protocols for large field-of-view abdominal-pelvic imaging in multicenter studies.

    Get PDF
    PURPOSE: To develop methods for optimization of diffusion-weighted MRI (DW-MRI) in the abdomen and pelvis on 1.5 T MR scanners from three manufacturers and assess repeatability of apparent diffusion coefficient (ADC) estimates in a temperature-controlled phantom and abdominal and pelvic organs in healthy volunteers. METHODS: Geometric distortion, ghosting, fat suppression, and repeatability and homogeneity of ADC estimates were assessed using phantoms and volunteers. Healthy volunteers (ten per scanner) were each scanned twice on the same scanner. One volunteer traveled to all three institutions in order to provide images for qualitative comparison. The common volunteer was excluded from quantitative analysis of the data from scanners 2 and 3 in order to ensure statistical independence, giving n = 10 on scanner 1 and n = 9 on scanners 2 and 3 for quantitative analysis. Repeatability and interscanner variation of ADC estimates in kidneys, liver, spleen, and uterus were assessed using within-patient coefficient of variation (wCV) and Kruskal-Wallis tests, respectively. RESULTS: The coefficient of variation of ADC estimates in the temperature-controlled phantom was 1%-4% for all scanners. Images of healthy volunteers from all scanners showed homogeneous fat suppression and no marked ghosting or geometric distortion. The wCV of ADC estimates was 2%-4% for kidneys, 3%-7% for liver, 6%-9% for spleen, and 7%-10% for uterus. ADC estimates in kidneys, spleen, and uterus showed no significant difference between scanners but a significant difference was observed in liver (p < 0.05). CONCLUSIONS: DW-MRI protocols can be optimized using simple phantom measurements to produce good quality images in the abdomen and pelvis at 1.5 T with repeatable quantitative measurements in a multicenter study

    Development of a temperature-controlled phantom for magnetic resonance quality assurance of diffusion, dynamic, and relaxometry measurements.

    Get PDF
    Purpose Diffusion-weighted (DW) and dynamic contrast-enhanced magnetic resonance imaging (MRI) are increasingly applied for the assessment of functional tissue biomarkers for diagnosis, lesion characterization, or for monitoring of treatment response. However, these techniques are vulnerable to the influence of various factors, so there is a necessity for a standardized MR quality assurance procedure utilizing a phantom to facilitate the reliable estimation of repeatability of these quantitative biomarkers arising from technical factors (e.g., B1 variation) affecting acquisition on scanners of different vendors and field strengths. The purpose of this study is to present a novel phantom designed for use in quality assurance for multicenter trials, and the associated repeatability measurements of functional and quantitative imaging protocols across different MR vendors and field strengths.Methods A cylindrical acrylic phantom was manufactured containing 7 vials of polyvinylpyrrolidone (PVP) solutions of different concentrations, ranging from 0% (distilled water) to 25% w/w, to create a range of different MR contrast parameters. Temperature control was achieved by equilibration with ice-water. Repeated MR imaging measurements of the phantom were performed on four clinical scanners (two at 1.5 T, two at 3.0 T; two vendors) using the same scanning protocol to assess the long-term and short-term repeatability. The scanning protocol consisted of DW measurements, inversion recovery (IR) T1 measurements, multiecho T2 measurement, and dynamic T1-weighted sequence allowing multiple variable flip angle (VFA) estimation of T1 values over time. For each measurement, the corresponding calculated parameter maps were produced. On each calculated map, regions of interest (ROIs) were drawn within each vial and the median value of these voxels was assessed. For the dynamic data, the autocorrelation function and their variance were calculated; for the assessment of the repeatability, the coefficients of variation (CoV) were calculated.Results For both field strengths across the available vendors, the apparent diffusion coefficient (ADC) at 0 °C ranged from (1.12 ± 0.01) × 10(-3) mm(2)/s for pure water to (0.48 ± 0.02) × 10(-3) mm(2)/s for the 25% w/w PVP concentration, presenting a minor variability between the vendors and the field strengths. T2 and IR-T1 relaxation time results demonstrated variability between the field strengths and the vendors across the different acquisitions. Moreover, the T1 values derived from the VFA method exhibited a large variation compared with the IR-T1 values across all the scanners for all repeated measurements, although the calculation of the standard deviation of the VFA-T1 estimate across each ROI and the autocorrelation showed a stability of the signal for three scanners, with autocorrelation of the signal over the dynamic series revealing a periodic variation in one scanner. Finally, the ADC, the T2, and the IR-T1 values exhibited an excellent repeatability across the scanners, whereas for the dynamic data, the CoVs were higher.Conclusions The combination of a novel PVP phantom, with multiple compartments to give a physiologically relevant range of ADC and T1 values, together with ice-water as a temperature-controlled medium, allows reliable quality assurance measurements that can be used to measure agreement between MRI scanners, critical in multicenter functional and quantitative imaging studies
    • …
    corecore