53 research outputs found

    Hydrochemical system analysis of public supply well fields, to reveal water-quality patterns and define groundwater bodies:The Netherlands

    Get PDF
    Hydrochemical system analysis (HCSA) is used to better understand the individual state of and spatial patterns in groundwater quality, by addressing the spatial distribution of groundwater bodies with specific origins (hydrosomes) and characteristic hydrochemical zones within each hydrosome (facies). The origin is determined by environmental tracers or geomorphological and potentiometric maps, the facies by combining age, redox and alkalinity indices. The HCSA method is applied to all 206 active public supply well fields (PSWFs) in The Netherlands, resulting in the distinction of nine hydrosomes and eleven facies parameters-age (young, intermediate, old), redox ((sub)oxic, anoxic, deep anoxic, mixed) and alkalinity (very low, low, intermediate and high). The resulting classification of PSWFs provides a means to (1) predict their vulnerability; (2) optimize groundwater-quality monitoring programs; and (3) better delineate groundwater bodies, by considering groundwater origin and flow. The HCSA translates complex hydrochemical patterns into easily interpretable maps by showing PSWFs, groundwater bodies and hydrochemical facies. Such maps facilitate communication between researchers, water resources managers and policy makers and can help to solve complex groundwater resources management problems at different scales, ranging from a single well(field) or region to the national or European scale. © 2010 Springer-Verlag

    The retention of trace elements on funnel surfaces of sampling equipment for wet deposition

    No full text
    In dit rapport worden de resultaten gepresenteerd van een onderzoek naar de mate van retentie van spoorelementen aan oppervlakken van trechters van regenwaterbemonsteringsapparatuur, i.c. wet-only vangers. Voor As, Co, Cr en Mn is de retentie verwaarloosbaar/niet meetbaar. Voor Cd en Cu en zeer waarschijnlijk ook Ni en V treedt er evenwicht op tussen de hoeveelheid metaal op de trechter en de concentratie in regenwater. Voor Fe en Pb neemt de hoeveelheid metaal op de trechter voortdurend toe met de tijd. De snelheid van accumulatie voor Pb neemt echter af met de tijd.Abstract not availableRIV

    Analysis of fly-ash samples, slags and sediments using X-ray fluorescence (XRF)

    No full text
    Dit rapport beschrijft de analyse van vliegassen, slakken en sedimenten. Twee voorbehandelingsmethoden zijn onderzocht, te weten het persen van een pil van een monster m.b.v. een bindmiddel en het maken van een glasparel van het monster m.b.v. lithiumtetraboraat. Drie procedures om het analytisch resultaat te verkrijgen werden toegepast: (i) berekening van het resultaat via een ijklijn, (ii) toepassing van standaardadditie en (iii) toepassing van de zgn. dubbele verdunningsmethode. De procedures werden beoordeeld aan de hand van de analyse van standaard-referentiematerialen. De dubbele verdunningsmethode kwam als beste naar voren. Hierbij werd gebruik gemaakt van het maken van glasparels als monstervoorbehandelingsprocedure.Abstract not availableRIV

    Method development for the determination of vanadium in drinking water with ultrasonic nebulazation and ICP-AES

    No full text
    Dit rapport beschrijft de methode-ontwikkeling voor de bepaling van vanadium in drinkwater met behulp van ICP-AES met toepassing van ultrasone verstuiving. Het onderzoek omvatte spectraalonderzoek voor de lijnkeuze, optimalisatie van de meetcondities, onderzoek naar memory-effecten en vaststellen van de diverse prestatiekenmerken. ICP-AES met ultrasone verstuiving bleek een zeer geschikte techniek voor de bepaling van vanadium in drinkwater te zijn . De onderste analysegrens werd vastgesteld op 0,4 mug/l. De precisie op het niveau van 25 mug/l en hoger, uitgedrukt als relatieve standaarddeviatie van de metingen, was beter dan 2%. Matrix-effecten speelden een geringe rol, met afwijkingen tot gemiddeld zo'n 7 %. Memory-effecten waren verwaarloosbaar bij een iets langere spoeltijd dan met conventionele (concentrische) verstuiving. Ondanks dat blijft deze techniek snel in vergelijking met andere atoomspectrometrische technieken zoals grafietoven-atomaire absorbtie spectrometrie.This report deals with the method development for the determination of vanadium in drinking water using ICP-AES and ultrasonic nebulization. The method development included spectral investigations for line selection, optimization of the measurement conditions, investigations concerning memory effects and assessment of the performance characteristics. ICP-AES with ultrasonic nebulization turned out to be a very suitable technique for the determination of vanadium in drinking water. The detection limit of the method was 0.4 mug/l. Precision at a concentration level of 25 mug/l and higher, expressed as a relative standard deviation, was better than 2%. Matrix effects played a minor role with deviations up to an average of 7%. Memory effects were negligable at a slightly longer rinsing time compared to conventional (concentric) nebulization. Despite that the technique is rapid in comparison to other atomic spectrometric techniques like graphite furnace atomic absorption spectrometry.RIV

    Determination of heavy metals in soil with ICP-AES after digestion in the microwavefurnace

    No full text
    Abstract niet beschikbaarOptimum conditions with respect to power, time and type of acid were established for the digestion of soil samples in a microwave furnace for the ICP-AES determination of trace metals. For the ICP-AES determination a selection for the proper spectral lines was made with respect to spectral interferences both "on the line" and at the position for the background measurement. The extent of matrix induced sensitivity changes was determined. The procedures were tested by digesting and analysing soil samples with known concentrations of trace metals.RIV

    Empirische procedure voor de reductie van matrixeffecten van samengestelde matrices bij inductief, plasma atomaire emissie spectrometrie gekoppeld met gebruikmaking van een interne standaard en proportionele correctie

    No full text
    Voor een inductief gekoppeld plasma zijn de matrixeffecten onderzocht voor matrixoplossingen met een enkele matrixcomponent (Na of Ca) en voor oplossingen met twee matrixcomponenten (Na plus Ca). Daarbij werd gebruik gemaakt van een ultrasone verstuiver en het plasma werd op de 'klassieke' manier bekeken (radiaal). Correctie voor matrixeffecten werd uitgevoerd door het gebruik van een interne standaard op twee manieren. Bij de ene manier werd het analietsignaal gedeeld door het signaal van de interne standaard (internal standard ratio method) en bij de tweede, nieuwe manier werd een proportionele correctie uitgevoerd in relatie tot het signaal van de interne standaard. Deze manier werd dan ook 'proportional correction' genoemd. Als interne standaardelementen werden yttrium en scandium gebruikt. De beste correctie werd verkregen met behulp van proportionele correctie, zowel voor enkelvoudige matrixcomponentsystemen als voor het tweevoudige matrixcomponentsysteem.The matrix effects for single-matrix component (Na or Ca) and mixed-matrix component (Na plus Ca) systems were investigated for an inductively coupled plasma with radial viewing and employing ultrasonic nebulization. Correction for matrix effects was carried out using the internal standard ratio method and a method named 'proportional correction' both with scandium and yttrium as internal standard elements. The best correction was observed using proportional correction both for the single-matrix component systems and for the mixed-matrix component system.RIV

    [Operationalization and performance characteristics of a Perkin Elmer Zeeman 4100 ZL atomic absorption spectrometer for the analysis of rainwater.]

    No full text
    Abstract niet beschikbaarThis report deals with the operationalization of a Perkin Elmer Zeeman 4100 ZL instrument for the determination of trace elements in rainwater. Choices were made for the settings of the various instrumental parameters. Performance characteristics were established and compared with the specifications supplied. The instrument met the suppliers specifications with respect to sensitivity, detection limits and precision. A comparative investigation with the formerly used equipment showed no significant or relevant differences in the results.RIV

    The determination of aluminium in sediments using a novel metlingtechnique and XRF

    No full text
    Dit rapport beschrijft de monstervoorbereiding met behulp van een nieuwe smelttechniek en de analytische aspecten van de bepaling met behulp van rontgenfluorescentiespectrometrie (XRF) van aluminium en slib. De aanleiding tot dit onderzoek was de noodzaak om analytisch-chemische bijstand te verlenen aan het project nr. 248476 "Mariene polonium-210". Hiertoe werd van een aantal slibmonsters het aluminiumgehalte bepaald ter normering van het polonium-210 gehalte van dit slib. De monstervoorbereiding vond plaats met nieuwe automatische apparatuur waarmee op zeer reproduceerbare wijze glasparels ten behoeve van XRF-analyse van vaste stoffen konden worden gemaakt. De fout in de monstervoorbereiding bedroeg ongeveer 1%. De procedure werd getest aan de hand van de analyse van standaard referentiematerialen.Abstract not availableRIV

    [Sampling of rainwater for the determination of mercury. An interim report.]

    No full text
    Abstract niet beschikbaarThe applicability of the wet-only rainwater-collectors of the Dutch 'Landelijk Meetnet Regenwater' for the sampling of rainwater for the determination of mercury was investigated. These collectors are applicable provided that the funnel and the collecting bottle are made of borosilicate glass. In the bottle an amount of concentrated HCL (1 + diluted with demineralized water) has to be placed prior to sampling in order to prevent losses of mercury caused by adsorption and/or volatilization. Diffusion of mercury from outer air to the collection liquid was negligible over a period of seven days.RIV

    [Operationalization and performance characteristics of a Spectro P ICP-AES instrument for the analysis of rainwater.]

    No full text
    Abstract niet beschikbaarThis report deals with the operationalization of a Spectro P ICP-AES instrument for the analysis of rainwater. Choices were made for the settings of the various instrumental parameters. Performance characteristics were established and compared with the specifications supplied. The instrument met the suppliers specifications with respect to detection limits, stability and precision. A comparative investigation with the formerly used equipment showed no significant or relevant differences in the results.RIV
    • …
    corecore