1,369 research outputs found

    Psychometric properties of a prostate cancer radiation late toxicity questionnaire

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>To construct a short prostate cancer radiation late toxicity (PCRT) questionnaire with health-related quality-of-life (HRQoL) domains.</p> <p>Methods</p> <p>The PCRT was developed by item generation, questionnaire construction (n = 7 experts, n = 8 focus group patients), pilot testing (n = 37), item reduction (n = 100), reliability testing (n = 237), and validity testing (n = 274).</p> <p>Results</p> <p>Reliability of the three item-reduced subscales demonstrated intraclass correlation coefficients (CC) of 0.811 (GU), 0.842 (GI), and 0.740 (sexual). Discriminant validity demonstrated Pearson CC of 0.449 (GU-GI), 0.200 (sexual-GU), and 0.09 (sexual-GI). Content validity correlations between PCRT-PCQoL were 0.35–0.78, PCRT-FACT-G<sup>© </sup>were 0.19–0.39, and PCRT-SF-36<sup>® </sup>were 0.03–0.34.</p> <p>Conclusion</p> <p>We successfully generated a PCRT HRQoL questionnaire including subscales with very good psychometric properties.</p

    Modular titanium alloy neck adapter failures in hip replacement - failure mode analysis and influence of implant material

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Modular neck adapters for hip arthroplasty stems allow the surgeon to modify CCD angle, offset and femoral anteversion intraoperatively. Fretting or crevice corrosion may lead to failure of such a modular device due to high loads or surface contamination inside the modular coupling. Unfortunately we have experienced such a failure of implants and now report our clinical experience with the failures in order to advance orthopaedic material research and joint replacement surgery.</p> <p>The failed neck adapters were implanted between August 2004 and November 2006 a total of about 5000 devices. After this period, the titanium neck adapters were replaced by adapters out of cobalt-chromium. Until the end of 2008 in total 1.4% (n = 68) of the implanted titanium alloy neck adapters failed with an average time of 2.0 years (0.7 to 4.0 years) postoperatively. All, but one, patients were male, their average age being 57.4 years (36 to 75 years) and the average weight 102.3 kg (75 to 130 kg). The failures of neck adapters were divided into 66% with small CCD of 130° and 60% with head lengths of L or larger. Assuming an average time to failure of 2.8 years, the cumulative failure rate was calculated with 2.4%.</p> <p>Methods</p> <p>A series of adapter failures of titanium alloy modular neck adapters in combination with a titanium alloy modular short hip stem was investigated. For patients having received this particular implant combination risk factors were identified which were associated with the occurence of implant failure. A Kaplan-Meier survival-failure-analysis was conducted. The retrieved implants were analysed using microscopic and chemical methods. Modes of failure were simulated in biomechanical tests. Comparative tests included modular neck adapters made of titanium alloy and cobalt chrome alloy material.</p> <p>Results</p> <p>Retrieval examinations and biomechanical simulation revealed that primary micromotions initiated fretting within the modular tapered neck connection. A continuous abrasion and repassivation process with a subsequent cold welding at the titanium alloy modular interface. Surface layers of 10 - 30 μm titanium oxide were observed. Surface cracks caused by fretting or fretting corrosion finally lead to fatigue fracture of the titanium alloy modular neck adapters. Neck adapters made of cobalt chrome alloy show significantly reduced micromotions especially in case of contaminated cone connection. With a cobalt-chromium neck the micromotions can be reduced by a factor of 3 compared to the titanium neck. The incidence of fretting corrosion was also substantially lower with the cobalt-chromium neck configuration.</p> <p>Conclusions</p> <p>Failure of modular titanium alloy neck adapters can be initiated by surface micromotions due to surface contamination or highly loaded implant components. In the present study, the patients at risk were men with an average weight over 100 kg. Modular cobalt chrome neck adapters provide higher safety compared to titanium alloy material.</p

    Farm management factors associated with bulk tank somatic cell count in Irish dairy herds

    Get PDF
    The relationship between bulk tank somatic cell count (SCC) and farm management and infrastructure was examined using data from 398 randomly selected, yet representative, Irish dairy farms where the basal diet is grazed grass. Median bulk tank SCC for the farms was 282,887 cells/ml ranging from 82,209 to 773,028 cells/ml. Two questionnaires were administered through face-to-face contact with each farmer. Herd-level factors associated with bulk tank SCC were determined using linear models with annual somatic cell score (i.e., arithmetic mean of the natural logarithm of bulk tank SCC) included as the dependent variable. All herd level factors were analysed individually in separate regression models, which included an adjustment for geographical location of the farm; a multiple regression model was subsequently developed. Management practices associated with low SCC included the use of dry cow therapy, participation in a milk recording scheme and the use of teat disinfection post-milking. There was an association between low SCC and an increased level of hygiene and frequency of cleaning of the holding yard, passageways and cubicles. Herd management factors associated with bulk tank SCC in Irish grazing herds are generally in agreement with most previous studies from confinement systems of milk production

    Depth-Sensing Indentation on REBa2Cu3O(7-\delta) Single Crystals obtained from Xenotime Mineral

    Full text link
    A natural mixture of heavy rare earths oxides extracted from xenotime mineral have been used to prepare large single crystals of high-temperature REBa2Cu3O(7-\delta) superconductor grown using the CuO-BaO self-flux method. Its mechanical properties along the ab-plane were characterized using instrumented indentation. Hardness and elastic modulus were obtained by the Oliver and Pharr method and corresponds to 7.4 \pm 0.2 GPa and in range 135-175 GPa at small depths, respectively. Increasing the load promotes the nucleation of lateral cracks that causes a decrease in hardness and the measured elastic modulus by instrumented indentation at higher loads. The indentation fracture toughness was estimated by measuring the radial crack length from cube-corner indentations at various loads and was 0.8 \pm 0.2 MPa.m1/2. The observed slip systems of REBa2Cu3O(7-\delta) single crystals were [100](001) and [010](001), the same as for YBa2Cu3O(7-\delta) single crystals. The initial stages of deformation and fracture in the indentation process were investigated. The hardness and elastic modulus were not strongly modified by the crystallographic orientation in the ab-plane. This was interpreted in terms of the resolved shear stresses in the active slip systems. Evidence of cracking along the {100} and {110} planes on the ab-plane was observed. As a conclusion, the mechanical properties of REBa2Cu3O(7-\delta) single crystals prepared from xenotime are equivalent to those of YBa2Cu3O(7-\delta) single crystals produced by conventional rare earths oxides.Comment: The paper will appear in Volume 42 (2012) of the Brazilian Journal of Physic

    Applying the revised Chinese Job Content Questionnaire to assess psychosocial work conditions among Taiwan's hospital workers

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>For hospital accreditation and health promotion reasons, we examined whether the 22-item Job Content Questionnaire (JCQ) could be applied to evaluate job strain of individual hospital employees and to determine the number of factors extracted from JCQ. Additionally, we developed an Excel module of self-evaluation diagnostic system for consultation with experts.</p> <p>Methods</p> <p>To develop an Excel-based self-evaluation diagnostic system for consultation to experts to make job strain assessment easier and quicker than ever, Rasch rating scale model was used to analyze data from 1,644 hospital employees who enrolled in 2008 for a job strain survey. We determined whether the 22-item Job Content Questionnaire (JCQ) could evaluate job strain of individual employees in work sites. The respective item responding to specific groups' occupational hazards causing job stress was investigated by using skewness coefficient with its 95% CI through item-by-item analyses.</p> <p>Results</p> <p>Each of those 22 items on the questionnaire was examined to have five factors. The prevalence rate of Chinese hospital workers with high job strain was 16.5%.</p> <p>Conclusions</p> <p>Graphical representations of four quadrants, item-by-item bar chart plots and skewness 95% CI comparison generated in Excel can help employers and consultants of an organization focusing on a small number of key areas of concern for each worker in job strain.</p

    Characterization of Leishmania spp. causing cutaneous leishmaniasis in Manaus, Amazonas, Brazil

    Get PDF
    In the State of Amazonas, American tegumentary leishmaniasis is endemic and presents a wide spectrum of clinical variability due to the large diversity of circulating species in the region. Isolates from patients in Manaus and its metropolitan region were characterized using monoclonal antibodies and isoenzymes belonging to four species of the parasite: Leishmania (Viannia) guyanensis, 73% (153/209); Leishmania (Viannia) braziliensis, 14% (30/209); Leishmania (Leishmania) amazonensis, 8% (17/209); and Leishmania (Viannia) naiffii, 4% (9/209). The most prevalent species was L. (V.) guyanensis. The principal finding of this study was the important quantity of infections involving more than one parasite species, representing 14% (29/209) of the total. The findings obtained in this work regarding the parasite are further highlighted by the fact that these isolates were obtained from clinical samples collected from single lesions

    Search for sterile neutrino mixing in the MINOS long-baseline experiment

    Get PDF
    A search for depletion of the combined flux of active neutrino species over a 735 km baseline is reported using neutral-current interaction data recorded by the MINOS detectors in the NuMI neutrino beam. Such a depletion is not expected according to conventional interpretations of neutrino oscillation data involving the three known neutrino flavors. A depletion would be a signature of oscillations or decay to postulated noninteracting sterile neutrinos, scenarios not ruled out by existing data. From an exposure of 3.18×1020 protons on target in which neutrinos of energies between ~500¿¿MeV and 120 GeV are produced predominantly as ¿µ, the visible energy spectrum of candidate neutral-current reactions in the MINOS far detector is reconstructed. Comparison of this spectrum to that inferred from a similarly selected near-detector sample shows that of the portion of the ¿µ flux observed to disappear in charged-current interaction data, the fraction that could be converting to a sterile state is less than 52% at 90% confidence level (C.L.). The hypothesis that active neutrinos mix with a single sterile neutrino via oscillations is tested by fitting the data to various models. In the particular four-neutrino models considered, the mixing angles ¿24 and ¿34 are constrained to be less than 11° and 56° at 90% C.L., respectively. The possibility that active neutrinos may decay to sterile neutrinos is also investigated. Pure neutrino decay without oscillations is ruled out at 5.4 standard deviations. For the scenario in which active neutrinos decay into sterile states concurrently with neutrino oscillations, a lower limit is established for the neutrino decay lifetime t3/m3&gt;2.1×10-12¿¿s/eV at 90% C.L

    Alimentary fluoride intake in preschool children

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The knowledge of background alimentary fluoride intake in preschool children is of utmost importance for introducing optimal and safe caries preventive measures for both individuals and communities. The aim of this study was to assess the daily fluoride intake analyzing duplicate samples of food and beverages. An attempt was made to calculate the daily intake of fluoride from food and swallowed toothpaste.</p> <p>Methods</p> <p>Daily alimentary fluoride intake was measured in a group of 36 children with an average age of 4.75 years and an average weight of 20.69 kg at baseline, by means of a double plate method. This was repeated after six months. Parents recorded their child's diet over 24 hours and collected duplicated portions of food and beverages received by children during this period. Pooled samples of food and beverages were weighed and solid food samples were homogenized. Fluoride was quantitatively extracted from solid food samples by a microdiffusion method using hexadecyldisiloxane and perchloric acid. The content of fluoride extracted from solid food samples, as well as fluoride in beverages, was measured potentiometrically by means of a fluoride ion selective electrode.</p> <p>Results</p> <p>Average daily fluoride intake at baseline was 0.389 (SD 0.054) mg per day. Six months later it was 0.378 (SD 0.084) mg per day which represents 0.020 (SD 0.010) and 0.018 (SD 0.008) mg of fluoride respectively calculated per kg bw/day.</p> <p>When adding the values of unwanted fluoride intake from the toothpaste shown in the literature (0.17-1.21 mg per day) the estimate of the total daily intake of fluoride amounted to 0.554-1.594 mg/day and recalculated to the child's body weight to 0.027-0.077 mg/kg bw/day.</p> <p>Conclusions</p> <p>In the children studied, observed daily fluoride intake reached the threshold for safe fluoride intake. When adding the potential fluoride intake from swallowed toothpaste, alimentary intake reached the optimum range for daily fluoride intake. These results showed that in preschool children, when trying to maximize the benefit of fluoride in caries prevention and to minimize its risk, caution should be exercised when giving advice on the fluoride containing components of child's diet or prescribing fluoride supplements.</p
    corecore