    Coronary pressure and flow relationships in humans: phasic analysis of normal and pathological vessels and the implications for stenosis assessment: a report from the Iberian-Dutch-English (IDEAL) collaborators

    Get PDF
    Our understanding of human coronary physiological behaviour is derived from animal models. We sought to describe physiological behaviour across a large collection of invasive pressure and flow velocity measurements, to provide a better understanding of the relationships between these physiological parameters and to evaluate the rationale for resting stenosis assessment.Five hundred and sixty-seven simultaneous intracoronary pressure and flow velocity assessments from 301 patients were analysed for coronary flow velocity, trans-stenotic pressure gradient (TG), and microvascular resistance (MVR). Measurements were made during baseline and hyperaemic conditions. The whole cardiac cycle and the diastolic wave-free period were assessed. Stenoses were assessed according to fractional flow reserve (FFR) and quantitative coronary angiography DS%. With progressive worsening of stenoses, from unobstructed angiographic normal vessels to those with FFR ≤ 0.50, hyperaemic flow falls significantly from 45 to 19 cm/s, Ptrend 0.05 for all). Trans-stenotic pressure gradient rose with stenosis severity for both rest and hyperaemic measures (Ptrend < 0.001 for both). Microvascular resistance declines with stenosis severity under resting conditions (Ptrend < 0.001), but was unchanged at hyperaemia (2.3 ± 1.1 mmHg/cm/s; Ptrend = 0.19).With progressive stenosis severity, TG rises. However, while hyperaemic flow falls significantly, resting coronary flow is maintained by compensatory reduction of MVR, demonstrating coronary auto-regulation. These data support the translation of coronary physiological concepts derived from animals to patients with coronary artery disease and furthermore, suggest that resting pressure indices can be used to detect the haemodynamic significance of coronary artery stenoses

    Baseline coronary pressures, instant wave-free ratio (iFR) and Pd/Pa: making the most of available information

    No full text
    AIMS: Adoption of fractional flow reserve (FFR) remains low (6-8%), partly because of the time, cost and potential inconvenience associated with vasodilator administration. The instantaneous wave-Free Ratio (iFR) is a pressure-only index of stenosis severity calculated without vasodilator drugs. Before outcome trials test iFR as a sole guide to revascularisation, we evaluate the merits of a hybrid iFR- FFR decision-making strategy for universal physiological assessment. METHODS AND RESULTS: Coronary pressure traces from 577 stenoses were analysed. iFR was calculated as the ratio between Pd and Pa in the resting diastolic wave-free window. A hybrid iFR-FFR strategy was evaluated, by allowing iFR to defer some stenoses (where negative predictive value is high) and treat others (where positive predictive value is high), with adenosine being given only to patients with iFR in between those values. For the most recent fixed FFR cut-off (0.8), an iFR of <0.86 could be used to confirm treatment (PPV of 92%), whilst an iFR value of >0.93 could be used to defer revascularisation (NPV of 91%). Limiting vasodilator drugs to cases with iFR values between 0.86 to 0.93 would obviate the need for vasodilator drugs in 57% of patients, whilst maintaining 95% agreement with an FFR-only strategy. If the 0.75-0.8 FFR grey zone is accounted for, vasodilator drug requirement would decrease by 76%. CONCLUSION: A hybrid iFR-FFR decision-making strategy for revascularisation could increase adoption of physiology-guided PCI, by more than halving the need for vasodilator administration, whilst maintaining high classification agreement with an FFR-only strategy

    Mechanisms of viral mutation

    No full text
    corecore