62 research outputs found
Sequential Structural and Fluid Dynamics Analysis of Balloon-Expandable Coronary Stents: A Multivariable Statistical Analysis
Several clinical studies have identified a strong correlation between neointimal hyperplasia following coronary stent deployment and both stent-induced arterial injury and altered vessel hemodynamics. As such, the sequential structural and fluid dynamics analysis of balloon-expandable stent deployment should provide a comprehensive indication of stent performance. Despite this observation, very few numerical studies of balloon-expandable coronary stents have considered both the mechanical and hemodynamic impact of stent deployment. Furthermore, in the few studies that have considered both phenomena, only a small number of stents have been considered. In this study, a sequential structural and fluid dynamics analysis methodology was employed to compare both the mechanical and hemodynamic impact of six balloon-expandable coronary stents. To investigate the relationship between stent design and performance, several common stent design properties were then identified and the dependence between these properties and both the mechanical and hemodynamic variables of interest was evaluated using statistical measures of correlation. Following the completion of the numerical analyses, stent strut thickness was identified as the only common design property that demonstrated a strong dependence with either the mean equivalent stress predicted in the artery wall or the mean relative residence time predicted on the luminal surface of the artery. These results corroborate the findings of the large-scale ISAR-STEREO clinical studies and highlight the crucial role of strut thickness in coronary stent design. The sequential structural and fluid dynamics analysis methodology and the multivariable statistical treatment of the results described in this study should prove useful in the design of future balloon-expandable coronary stents
Carotid plaque regression following 6-month statin therapy assessed by 3T cardiovascular magnetic resonance: comparison with ultrasound intima media thickness
<p>Abstract</p> <p>Background</p> <p>Cardiovascular magnetic resonance (CMR) allows volumetric carotid plaque measurement that has advantage over 2-dimensional ultrasound (US) intima-media thickness (IMT) in evaluating treatment response. We tested the hypothesis that 6-month statin treatment in patients with carotid plaque will lead to plaque regression when measured by 3 Tesla CMR but not by IMT.</p> <p>Methods</p> <p>Twenty-six subjects (67 ± 2 years, 7 females) with known carotid plaque (> 1.1 mm) and coronary or cerebrovascular atherosclerotic disease underwent 3T CMR (T1, T2, proton density and time of flight sequences) and US at baseline and following 6 months of statin therapy (6 had initiation, 7 had increase and 13 had maintenance of statin dosing). CMR plaque volume (PV) was measured in the region 12 mm below and up to 12 mm above carotid flow divider using software. Mean posterior IMT in the same region was measured. Baseline and 6-month CMR PV and US IMT were compared. Change in lipid rich/necrotic core (LR/NC) and calcification plaque components from CMR were related to change in PV.</p> <p>Results</p> <p>Low-density lipoprotein cholesterol decreased (86 ± 6 to 74 ± 4 mg/dL, p = 0.046). CMR PV decreased 5.8 ± 2% (1036 ± 59 to 976 ± 65 mm<sup>3</sup>, p = 0.018). Mean IMT was unchanged (1.12 ± 0.06 vs. 1.14 ± 0.06 mm, p = NS). Patients with initiation or increase of statins had -8.8 ± 2.8% PV change (p = 0.001) while patients with maintenance of statin dosing had -2.7 ± 3% change in PV (p = NS). There was circumferential heterogeneity in CMR plaque thickness with greatest thickness in the posterior carotid artery, in the region opposite the flow divider. Similarly there was circumferential regional difference in <it>change </it>of plaque thickness with significant plaque regression in the anterior carotid region in region of the flow divider. Change in LR/NC (R = 0.62, p = 0.006) and calcification (R = 0.45, p = 0.03) correlated with PV change.</p> <p>Conclusions</p> <p>Six month statin therapy in patients with carotid plaque led to reduced plaque volume by 3T CMR, but ultrasound posterior IMT did not show any change. The heterogeneous spatial distribution of plaque and regional differences in magnitude of plaque regression may explain the difference in findings and support volumetric measurement of plaque. 3T CMR has potential advantage over ultrasound IMT to assess treatment response in individuals and may allow reduced sample size, duration and cost of clinical trials of plaque regression.</p
Haemodynamics and flow modification stents for peripheral arterial disease:a review
Endovascular stents are widely used for the treatment of peripheral arterial disease (PAD). However, the development of in-stent restenosis and downstream PAD progression remain a challenge. Stent revascularisation of PAD causes arterial trauma and introduces abnormal haemodynamics, which initiate complicated biological processes detrimental to the arterial wall. The interaction between stent struts and arterial cells in contact, and the blood flow field created in a stented region, are highly affected by stent design. Spiral flow is known as a normal physiologic characteristic of arterial circulation and is believed to prevent the development of flow disturbances. This secondary flow motion is lost in atheromatous disease and its re-introduction after endovascular treatment of PAD has been suggested as a method to induce stabilised and coherent haemodynamics. Stent designs able to generate spiral flow may support endothelial function and therefore increase patency rates. This review is focused on secondary flow phenomena in arteries and the development of flow modification stent technologies for the treatment of PAD
Contribution of Mechanical and Fluid Stresses to the Magnitude of In-stent Restenosis at the Level of Individual Stent Struts
Structural and fluid stresses acting on the artery wall are proposed as mechanical mediators of in-stent restenosis (ISR). This study reports an investigation of the correlation between stresses obtained from computational simulations with the magnitude of ISR at the level of individual stent struts observed in an in vivo model of restenosis. Structural and fluid dynamic analyses were undertaken in a model based on volumetric micro-CT data from an in vivo stent deployment in a porcine right coronary artery. Structural and fluid mechanics were compared with histological data from the same stented vessel sample. Interpretation of the combined data at the level of individual stent struts was possible by identifying the location of each 2-D histological section within the 3-D micro-CT volume. Linear correlation between structural and fluid stimuli and neointimal thickness at the level of individual struts is less clear when individual stimuli are considered [compressive force (CF), R 2 = 0.19, wall shear stress (WSS), R 2 = 0.25, oscillatory shear index (OSI), R 2 = 0.28]. Closer correlation is observed if combined structural and fluid stimuli are assumed to stimulate ISR (CF/WSS, R 2 = 0.64). The use of micro-CT to characterise stent geometry after deployment enhances the clinical relevance of computational simulations, allowing direct comparison with histology. The results support the combined role of both structural and fluid mechanics to determine the magnitude of ISR at the level of individual struts. This finding is consistent with other studies which consider these stimuli averaged over a transverse section of the vessel
- …