16 research outputs found

    In vivo comparison of arterial lumen dimensions assessed by co-registered three-dimensional (3D) quantitative coronary angiography, intravascular ultrasound and optical coherence tomography

    Get PDF
    This study sought to compare lumen dimensions as assessed by 3D quantitative coronary angiography (QCA) and by intravascular ultrasound (IVUS) or optical coherence tomography (OCT), and to assess the association of the discrepancy with vessel curvature. Coronary lumen dimensions often show discrepancies when assessed by X-ray angiography and by IVUS or OCT. One source of error concerns a possible mismatch in the selection of corresponding regions for the comparison. Therefore, we developed a novel, real-time co-registration approach to guarantee the point-to-point correspondence between the X-ray, IVUS and OCT images. A total of 74 patients with indication for cardiac catheterization were retrospectively included. Lumen morphometry was performed by 3D QCA and IVUS or OCT. For quantitative analysis, a novel, dedicated approach for co-registration and lumen detection was employed allowing for assessment of lumen size at multiple positions along the vessel. Vessel curvature was automatically calculated from the 3D arterial vessel centerline. Comparison of 3D QCA and IVUS was performed in 519 distinct positions in 40 vessels. Correlations were r = 0.761, r = 0.790, and r = 0.799 for short diameter (SD), long diameter (LD), and area, respectively. Lumen sizes were larger by IVUS (P < 0.001): SD, 2.51 ± 0.58 mm versus 2.34 ± 0.56 mm; LD, 3.02 ± 0.62 mm versus 2.63 ± 0.58 mm; Area, 6.29 ± 2.77 mm2versus 5.08 ± 2.34 mm2. Comparison of 3D QCA and OCT was performed in 541 distinct positions in 40 vessels. Correlations were r = 0.880, r = 0.881, and r = 0.897 for SD, LD, and area, respectively. Lumen sizes were larger by OCT (P < 0.001): SD, 2.70 ± 0.65 mm versus 2.57 ± 0.61 mm; LD, 3.11 ± 0.72 mm versus 2.80 ± 0.62 mm; Area 7.01 ± 3.28 mm2versus 5.93 ± 2.66 mm2. The vessel-based discrepancy between 3D QCA and IVUS or OCT long diameters increased with increasing vessel curvature. In conclusion, our comparison of co-registered 3D QCA and invasive imaging data suggests a bias towards larger lume

    Coronary microvascular resistance: methods for its quantification in humans

    Get PDF
    Coronary microvascular dysfunction is a topic that has recently gained considerable interest in the medical community owing to the growing awareness that microvascular dysfunction occurs in a number of myocardial disease states and has important prognostic implications. With this growing awareness, comes the desire to accurately assess the functional capacity of the coronary microcirculation for diagnostic purposes as well as to monitor the effects of therapeutic interventions that are targeted at reversing the extent of coronary microvascular dysfunction. Measurements of coronary microvascular resistance play a pivotal role in achieving that goal and several invasive and noninvasive methods have been developed for its quantification. This review is intended to provide an update pertaining to the methodology of these different imaging techniques, including the discussion of their strengths and weaknesses

    A CT-based Medina Classification in Coronary Bifurcations: Does the Lumen Assessment Provide Sufficient Information?

    No full text
    Aims: To evaluate the distribution of atherosclerosis at bifurcations with computed tomography coronary angiography (CTCA) and propose a novel CT-Medina classification for bifurcation lesions. Methods: In 26 patients (age 55 +/- 10 years, 81% male) imaged with CTCA, 39 bifurcations were studied. The bifurcations analysis included the proximal main vessel, the distal main vessel and the side branch (SB). Plaque contours were manually traced on CTCA; the lumen, vessel and plaque area were measured, as well as plaque burden (%). The carina cross-sections were divided into four equal parts according to the expected wall shear stress (WSS) to assess circumferential plaque distribution. All the bifurcation lesions were classified using the Medina classification and a novel CT-Medina classification combining lumen narrowing and plaque burden >= 70%. Results: Presence of severe plaque (plaque burden >= 70%) by CTCA was demonstrated in 12.8% (5/39) of the proximal segments, 15.4% (6/39) of the distal segments and 7.7% (3/39) of the SB segments. The thickest plaque was located more often in low WSS parts of the carina cross-sections, whereas the flow divider was rarely affected. Although in the majority of bifurcations plaque was present, based on the Medina classification 92% of the assessed bifurcations were identified as 0,0,0. Characterization of bifurcation lesions using the new CT-Medina classification provided additional information in seven cases (18%) compared to the Medina classification Conclusion: Atherosclerotic plaque is widely present in all bifurcation segments, even in the absence of coronary lumen stenosis. A CT-Medina classification combining lumen and plaque parameters is more informative than angiographic classification of bifurcation lesions and could potentially facilitate the decision-making on the treatment of these lesions. (C) 2014 Wiley Periodicals, Inc

    Fast virtual functional assessment of intermediate coronary lesions using routine angiographic data and blood flow simulation in humans: comparison with pressure wire – fractional flow reserve

    No full text
    Aims: To develop a simplified approach of virtual functional assessment of coronary stenosis from routine angiographic data and test it against fractional flow reserve using a pressure wire (wire-FFR). Methods and results: Three-dimensional quantitative coronary angiography (3D-QCA) was performed in 139 vessels (120 patients) with intermediate lesions assessed by wire-FFR (reference standard: <0.80). The 3D-QCA models were processed with computational fluid dynamics (CFD) to calculate the lesion-specific pressure gradient (AP) and construct the AP flow curve, from which the virtual functional assessment index (vFAI) was derived. The discriminatory power of vFAI for ischaemia-producing lesions was high (area under the receiver operator characteristic curve [AUC]: 92% [95% CI: 86-96%]). Diagnostic accuracy, sensitivity and specificity for the optimal vFAI cut-point (<= 0.82) were 88%, 90% and 86%, respectively. VirtualFAT demonstrated superior discrimination against 3D-QCA derived % area stenosis (AUC: 78% [95% CI: 70-84%]; p<0.0001 compared to vFAI). There was a close correlation (r=0.78, p<0.0001) and agreement of vFAI compared to wire-FFR (mean difference: 0.0039+0.085, p=0.59). Conclusions: We developed a fast and simple CFD-powered virtual haemodynamic assessment model using only routine angiography and without requiring any invasive physiology measurements/hyperaemia induction. Virtual-FM showed a high diagnostic performance and incremental value to QCA for predicting wireFFR; this "less invasive" approach could have important implications for patient management and cost
    corecore