146 research outputs found
Novel imaging phantom for accurate and robust measurement of brain atrophy rates using clinical MRI
Brain volume loss, or atrophy, has been proven to be an important characteristic of neurological diseases such as Alzheimer's disease and multiple sclerosis. To use atrophy rate as a reliable clinical biomarker and to increase statistical power in clinical treatment trials, measurement variability needs to be minimized. Among other sources, systematic differences between different MR scanners are suspected to contribute to this variability. In this study we developed and performed initial validation tests of an MR-compatible phantom and analysis software for robust and reliable evaluation of the brain volume loss. The phantom contained three inflatable models of brain structures, i.e. cerebral hemisphere, putamen, and caudate nucleus. Software to reliably quantify volumes form the phantom images was also developed. To validate the method, the phantom was imaged using 3D T1-weighted protocols at three clinical 3T MR scanners from different vendors. Calculated volume change from MRI was compared with the known applied volume change using ICC and mean absolute difference. As assessed by the ICC, the agreement between our developed software and the applied volume change for different structures ranged from 0.999-1 for hemisphere, 0.976-0.998 for putamen, and 0.985-0.999 for caudate nucleus. The mean absolute differences between measured and applied volume change were 109-332 μL for hemisphere, 2.9-11.9 μL for putamen, and 2.2-10.1 μL for caudate nucleus. This method offers a reliable and robust measurement of volume change using MR images and could potentially be used to standardize clinical measurement of atrophy rates
Effects of dipole position, orientation and noise on the accuracy of EEG source localization
BACKGROUND: The electroencephalogram (EEG) reflects the electrical activity in the brain on the surface of scalp. A major challenge in this field is the localization of sources in the brain responsible for eliciting the EEG signal measured at the scalp. In order to estimate the location of these sources, one must correctly model the sources, i.e., dipoles, as well as the volume conductor in which the resulting currents flow. In this study, we investigate the effects of dipole depth and orientation on source localization with varying sets of simulated random noise in 4 realistic head models. METHODS: Dipole simulations were performed using realistic head models and using the boundary element method (BEM). In all, 92 dipole locations placed in temporal and parietal regions of the head with varying depth and orientation were investigated along with 6 different levels of simulated random noise. Localization errors due to dipole depth, orientation and noise were investigated. RESULTS: The results indicate that there are no significant differences in localization error due tangential and radial dipoles. With high levels of simulated Gaussian noise, localization errors are depth-dependant. For low levels of added noise, errors are similar for both deep and superficial sources. CONCLUSION: It was found that if the signal-to-noise ratio is above a certain threshold, localization errors in realistic head models are, on average the same for deep and superficial sources. As the noise increases, localization errors increase, particularly for deep sources
Non-linear registration improves statistical power to detect hippocampal atrophy in aging and dementia
OBJECTIVE: To compare the performance of different methods for determining hippocampal atrophy rates using longitudinal MRI scans in aging and Alzheimer's disease (AD). // BACKGROUND: Quantifying hippocampal atrophy caused by neurodegenerative diseases is important to follow the course of the disease. In dementia, the efficacy of new therapies can be partially assessed by measuring their effect on hippocampal atrophy. In radiotherapy, the quantification of radiation-induced hippocampal volume loss is of interest to quantify radiation damage. We evaluated plausibility, reproducibility and sensitivity of eight commonly used methods to determine hippocampal atrophy rates using test-retest scans. // MATERIALS AND METHODS: Manual, FSL-FIRST, FreeSurfer, multi-atlas segmentation (MALF) and non-linear registration methods (Elastix, NiftyReg, ANTs and MIRTK) were used to determine hippocampal atrophy rates on longitudinal T1-weighted MRI from the ADNI database. Appropriate parameters for the non-linear registration methods were determined using a small training dataset (N = 16) in which two-year hippocampal atrophy was measured using test-retest scans of 8 subjects with low and 8 subjects with high atrophy rates. On a larger dataset of 20 controls, 40 mild cognitive impairment (MCI) and 20 AD patients, one-year hippocampal atrophy rates were measured. A repeated measures ANOVA analysis was performed to determine differences between controls, MCI and AD patients. For each method we calculated effect sizes and the required sample sizes to detect one-year volume change between controls and MCI (NCTRL_MCI) and between controls and AD (NCTRL_AD). Finally, reproducibility of hippocampal atrophy rates was assessed using within-session rescans and expressed as an average distance measure DAve, which expresses the difference in atrophy rate, averaged over all subjects. The same DAve was used to determine the agreement between different methods. RESULTS: Except for MALF, all methods detected a significant group difference between CTRL and AD, but none could find a significant difference between the CTRL and MCI. FreeSurfer and MIRTK required the lowest sample sizes (FreeSurfer: NCTRL_MCI = 115, NCTRL_AD = 17 with DAve = 3.26%; MIRTK: NCTRL_MCI = 97, NCTRL_AD = 11 with DAve = 3.76%), while ANTs was most reproducible (NCTRL_MCI = 162, NCTRL_AD = 37 with DAve = 1.06%), followed by Elastix (NCTRL_MCI = 226, NCTRL_AD = 15 with DAve = 1.78%) and NiftyReg (NCTRL_MCI = 193, NCTRL_AD = 14 with DAve = 2.11%). Manually measured hippocampal atrophy rates required largest sample sizes to detect volume change and were poorly reproduced (NCTRL_MCI = 452, NCTRL_AD = 87 with DAve = 12.39%). Atrophy rates of non-linear registration methods also agreed best with each other. // DISCUSSION AND CONCLUSION: Non-linear registration methods were most consistent in determining hippocampal atrophy and because of their better reproducibility, methods, such as ANTs, Elastix and NiftyReg, are preferred for determining hippocampal atrophy rates on longitudinal MRI. Since performances of non-linear registration methods are well comparable, the preferred method would mostly depend on computational efficiency
Inter-rater agreement in glioma segmentations on longitudinal MRI
Background
Tumor segmentation of glioma on MRI is a technique to monitor, quantify and report disease progression. Manual MRI segmentation is the gold standard but very labor intensive. At present the quality of this gold standard is not known for different stages of the disease, and prior work has mainly focused on treatment-naive glioblastoma. In this paper we studied the inter-rater agreement of manual MRI segmentation of glioblastoma and WHO grade II-III glioma for novices and experts at three stages of disease. We also studied the impact of inter-observer variation on extent of resection and growth rate.
Methods
In 20 patients with WHO grade IV glioblastoma and 20 patients with WHO grade II-III glioma (defined as non-glioblastoma) both the enhancing and non-enhancing tumor elements were segmented on MRI, using specialized software, by four novices and four experts before surgery, after surgery and at time of tumor progression. We used the generalized conformity index (GCI) and the intra-class correlation coefficient (ICC) of tumor volume as main outcome measures for inter-rater agreement.
Results
For glioblastoma, segmentations by experts and novices were comparable. The inter-rater agreement of enhancing tumor elements was excellent before surgery (GCI 0.79, ICC 0.99) poor after surgery (GCI 0.32, ICC 0.92), and good at progression (GCI 0.65, ICC 0.91). For non-glioblastoma, the inter-rater agreement was generally higher between experts than between novices. The inter-rater agreement was excellent between experts before surgery (GCI 0.77, ICC 0.92), was reasonable after surgery (GCI 0.48, ICC 0.84), and good at progression (GCI 0.60, ICC 0.80). The inter-rater agreement was good between novices before surgery (GCI 0.66, ICC 0.73), was poor after surgery (GCI 0.33, ICC 0.55), and poor at progression (GCI 0.36, ICC 0.73). Further analysis showed that the lower inter-rater agreement of segmentation on postoperative MRI could only partly be explained by the smaller volumes and fragmentation of residual tumor. The median interquartile range of extent of resection between raters was 8.3% and of growth rate was 0.22 mm/year.
Conclusion
Manual tumor segmentations on MRI have reasonable agreement for use in spatial and volumetric analysis. Agreement in spatial overlap is of concern with segmentation after surgery for glioblastoma and with segmentation of non-glioblastoma by non-experts
Closed-form analytical expressions for the potential fields generated by triangular monolayers with linearly distributed source strength
The solution of the mixed boundary value problem of potential theory involves the computation of the potential field generated by monolayer and double layer source distributions on surfaces at which boundary conditions are known. Closed-form analytical expressions have been described in the literature for the potential field generated by double layers having a linearly distributed strength over triangular source elements. This contribution presents the corresponding expression for the linearly distributed monolayer strength. The solution is shown to be valid for all observation points in space, including those on the interior, edges and vertices of the source triangle
Comparing Glioblastoma Surgery Decisions Between Teams Using Brain Maps of Tumor Locations, Biopsies, and Resections
PURPOSE: The aim of glioblastoma surgery is to maximize the extent of resection while preserving functional integrity, which depends on the location within the brain. A standard to compare these decisions is lacking. We present a volumetric voxel-wise method for direct comparison between two multidisciplinary teams of glioblastoma surgery decisions throughout the brain. METHODS: Adults undergoing first-time glioblastoma surgery from 2012 to 2013 performed by two neuro-oncologic teams were included. Patients had had a diagnostic biopsy or resection. Preoperative tumors and postoperative residues were segmented on magnetic resonance imaging in three dimensions and registered to standard brain space. Voxel-wise probability maps of tumor location, biopsy, and resection were constructed for each team to compare patient referral bias, indication variation, and treatment variation. To evaluate the quality of care, subgroups of differentially resected brain regions were analyzed for survival and functional outcome. RESULTS: One team included 101 patients, and the other included 174; 91 tumors were biopsied, and 181 were resected. Patient characteristics were largely comparable between teams. Distributions of tumor locations were dissimilar, suggesting referral bias. Distributions of biopsies were similar, suggesting absence of indication variation. Differentially resected regions were identified in the anterior limb of the right internal capsule and the right caudate nucleus, indicating treatment variation. Patients with (n = 12) and without (n = 6) surgical removal in these regions had similar overall survival and similar permanent neurologic deficits. CONCLUSION: Probability maps of tumor location, biopsy, and resection provide additional information that can inform surgical decision making across multidisciplinary teams for patients with glioblastoma
Functional brain network centrality is related to APOE genotype in cognitively normal elderly
INTRODUCTION: Amyloid plaque deposition in the brain is an early pathological change in Alzheimer's disease (AD), causing disrupted synaptic connections. Brain network disruptions in AD have been demonstrated with eigenvector centrality (EC), a measure that identifies central regions within networks. Carrying an apolipoprotein (APOE)-ε4 allele is a genetic risk for AD, associated with increased amyloid deposition. We studied whether APOE-ε4 carriership is associated with EC disruptions in cognitively normal individuals. METHODS: A total of 261 healthy middle-aged to older adults (mean age 56.6 years) were divided into high-risk (APOE-ε4 carriers) and low-risk (noncarriers) groups. EC was computed from resting-state functional MRI data. Clusters of between-group differences were assessed with a permutation-based method. Correlations between cluster mean EC with brain volume, CSF biomarkers, and psychological test scores were assessed. RESULTS: Decreased EC in the visual cortex was associated with APOE-ε4 carriership, a genetic risk factor for AD. EC differences were correlated with age, CSF amyloid levels, and scores on the trail-making and 15-object recognition tests. CONCLUSION: Our findings suggest that the APOE-ε4 genotype affects brain connectivity in regions previously found to be abnormal in AD as a sign of very early disease-related pathology. These differences were too subtle in healthy elderly to use EC for single-subject prediction of APOE genotype
Donepezil Impairs Memory in Healthy Older Subjects: Behavioural, EEG and Simultaneous EEG/fMRI Biomarkers
Rising life expectancies coupled with an increasing awareness of age-related cognitive decline have led to the unwarranted use of psychopharmaceuticals, including acetylcholinesterase inhibitors (AChEIs), by significant numbers of healthy older individuals. This trend has developed despite very limited data regarding the effectiveness of such drugs on non-clinical groups and recent work indicates that AChEIs can have negative cognitive effects in healthy populations. For the first time, we use a combination of EEG and simultaneous EEG/fMRI to examine the effects of a commonly prescribed AChEI (donepezil) on cognition in healthy older participants. The short- and long-term impact of donepezil was assessed using two double-blind, placebo-controlled trials. In both cases, we utilised cognitive (paired associates learning (CPAL)) and electrophysiological measures (resting EEG power) that have demonstrated high-sensitivity to age-related cognitive decline. Experiment 1 tested the effects of 5 mg/per day dosage on cognitive and EEG markers at 6-hour, 2-week and 4-week follow-ups. In experiment 2, the same markers were further scrutinised using simultaneous EEG/fMRI after a single 5 mg dose. Experiment 1 found significant negative effects of donepezil on CPAL and resting Alpha and Beta band power. Experiment 2 replicated these results and found additional drug-related increases in the Delta band. EEG/fMRI analyses revealed that these oscillatory differences were associated with activity differences in the left hippocampus (Delta), right frontal-parietal network (Alpha), and default-mode network (Beta). We demonstrate the utility of simple cognitive and EEG measures in evaluating drug responses after acute and chronic donepezil administration. The presentation of previously established markers of age-related cognitive decline indicates that AChEIs can impair cognitive function in healthy older individuals. To our knowledge this is the first study to identify the precise neuroanatomical origins of EEG drug markers using simultaneous EEG/fMRI. The results of this study may be useful for evaluating novel drugs for cognitive enhancement
- …