14 research outputs found

    Comparison of flow characteristics and vascular reactivity of radial artery and long saphenous vein grafts [NCT00139399]

    Get PDF
    BACKGROUND: The morphological and functional differences between arteries and veins may have implications on coronary artery bypass graft (CABG) survival. Although subjective differences have been observed between radial artery (RA) and long saphenous venous (LSV) grafts, these have not been quantified. This study assessed and compared the flow characteristics and in-vivo graft flow responses of RA and LSV aorto-coronary grafts. METHODS: Angiograms from 52 males taken 3.7 ± 1.0 months after CABG surgery were analyzed using adjusted Thrombolysis in Myocardial Infarction (TIMI) frame count. Graft and target coronary artery dimensions were measured using quantitative coronary angiography. Estimated TIMI velocity (V(E)) and volume flow (F(E)) were then calculated. A further 7 patients underwent in-vivo graft flow responses assessments to adenosine, acetylcholine and isosorbide dinitrate (ISDN) using intravascular Doppler. RESULTS: The V(E )for RA grafts was significantly greater than LSV grafts (P = 0.002), however there was no difference in volume F(E )(P = 0.20). RA grafts showed positive endothelium-dependent and -independent vasodilatation, and LSV grafts showed no statistically significant response to adenosine and acetylcholine. There was no difference in flow velocity or volume responses. Seven RA grafts (11%) had compromised patency (4 (6%) ≥ 50% stenosis in the proximal/distal anastomoses, and 3 (5%) diffuse narrowing). Thirty-seven (95%) LSV grafts achieved perfect patency and 2 (5%) were occluded. CONCLUSION: The flow characteristics and flow responses of the RA graft suggest that it is a more physiological conduit than the LSV graft. The clinical relevance of the balance between imperfect patency versus the more physiological vascular function in the RA graft may be revealed by the 5-year angiographic follow-up of this trial

    Flow-Dependent Mass Transfer May Trigger Endothelial Signaling Cascades

    Get PDF
    It is well known that fluid mechanical forces directly impact endothelial signaling pathways. But while this general observation is clear, less apparent are the underlying mechanisms that initiate these critical signaling processes. This is because fluid mechanical forces can offer a direct mechanical input to possible mechanotransducers as well as alter critical mass transport characteristics (i.e., concentration gradients) of a host of chemical stimuli present in the blood stream. However, it has recently been accepted that mechanotransduction (direct mechanical force input), and not mass transfer, is the fundamental mechanism for many hemodynamic force-modulated endothelial signaling pathways and their downstream gene products. This conclusion has been largely based, indirectly, on accepted criteria that correlate signaling behavior and shear rate and shear stress, relative to changes in viscosity. However, in this work, we investigate the negative control for these criteria. Here we computationally and experimentally subject mass-transfer limited systems, independent of mechanotransduction, to the purported criteria. The results showed that the negative control (mass-transfer limited system) produced the same trends that have been used to identify mechanotransduction-dominant systems. Thus, the widely used viscosity-related shear stress and shear rate criteria are insufficient in determining mechanotransduction-dominant systems. Thus, research should continue to consider the importance of mass transfer in triggering signaling cascades

    A potential mechanism of arterial spasm

    Full text link

    Effect of powdered gloves, worn at the time of embryo transfer, on the pregnancy outcome of IVF cycles

    No full text
    Purpose: To assess the effect of wearing powdered gloves during embryo transfer as compared to un-powdered gloves on the pregnancy outcome of IVF cycles. Methods: Patients, undergoing embryo transfer procedures, were prospectively randomized into two groups: In the first (group A, n=356) group embryo transfer was performed while wearing powdered gloves; in the second (group B, n=356) group embryo transfer was performed while wearing un-powdered gloves. The primary end point of the study was the clinical pregnancy rate. Results: The two groups were comparable with respect to the mean age, mean number of grade one embryos obtained, and the mean number of embryos transferred. The clinical pregnancy rates of the two groups were not different. Conclusions: Powdered gloves, worn during embryo transfer, have no adverse effect on the pregnancy outcome of IVF cycles. © 2008 Springer Science+Business Media, LLC.CRITCHLOW JD, 1989, HUM REPROD, V4, P545; Franklin Elizabeth, 1992, Andrias, V9, P5; KRUGER TF, 1985, S AFR MED J, V67, P241; Lierman S, 2007, FERTIL STERIL, V88, P1266, DOI 10.1016-j.fertnstert.2007.01.113; NAZ RK, 1986, FERTIL STERIL, V46, P914; Reddy VR, 1999, J BIOMED MATER RES, V48, P569, DOI 10.1002-(SICI)1097-4636(1999)48:4569::AID-JBM243.0.CO;2-G; SHAREFKIN JB, 1986, J SURG RES, V41, P465, DOI DOI 10.1016-0022-4804(86)90163-0; 1980, BMJ, V281, P8920
    corecore