65 research outputs found

    Production of Androgens by Microbial Transformation of Progesterone in Vitro: A Model for Androgen Production in Rivers Receiving Paper Mill Effluent

    Get PDF
    We have previously documented the presence of progesterone and androstenedione in the water column and bottom sediments of the Fenholloway River, Taylor County, Florida. This river receives paper mill effluent and contains masculinized female mosquitofish. We hypothesized that plant sterols (e.g., β-sitosterol) derived from the pulping of pine trees are transformed by bacteria into progesterone and subsequently into 17α-hydroxyprogesterone, androstenedione, and other androgens. In this study, we demonstrate that these same androgens can be produced in vitro from the bacterium Mycobacterium smegmatis. In a second part to this study, we reextracted and reanalyzed the sediment from the Fenholloway River and verified the presence of androstadienedione, a Δ1 steroid with androgen activity

    Sonographically Guided Core Biopsy of the Breast: Comparison of 14-Gauge Automated Gun and 11-Gauge Directional Vacuum-Assisted Biopsy Methods

    Get PDF
    OBJECTIVE: To compare the outcomes of 14-gauge automated biopsy and 11-gauge vacuum-assisted biopsy for the sonographically guided core biopsies of breast lesions. MATERIALS AND METHODS: We retrospectively reviewed all sonographically guided core biopsies performed from January 2002 to February 2004. The sonographically guided core biopsies were performed with using a 14-gauge automated gun on 562 breast lesions or with using an 11-gauge vacuum-assisted device on 417 lesions. The histologic findings were compared with the surgical, imaging and follow-up findings. The histologic underestimation rate, the repeat biopsy rate and the false negative rates were compared between the two groups. RESULTS: A repeat biopsy was performed on 49 benign lesions because of the core biopsy results of the high-risk lesions (n = 24), the imaging-histologic discordance (n = 5), and the imaging findings showing disease progression (n = 20). The total underestimation rates, according to the biopsy device, were 55% (12/22) for the 14-gauge automated gun biopsies and 36% (8/22) for the 11-gauge vacuum-assisted device (p = 0.226). The atypical ductal hyperplasia (ADH) underestimation (i.e., atypical ductal hyperplasia at core biopsy and carcinoma at surgery) was 58% (7/12) for the 14-gauge automated gun biopsies and 20% (1/5) for the 11-gauge vacuum-assisted biopsies. The ductal carcinoma in situ (DCIS) underestimation rate (i.e., ductal carcinoma in situ upon core biopsy and invasive carcinoma found at surgery) was 50% (5/10) for the 14-gauge automated gun biopsies and 41% (7/17) for the 11-gauge vacuum-assisted biopsies. The repeat biopsy rates were 6% (33/562) for the 14-gauge automated gun biopsies and 3.5% (16/417) for the 11-gauge vacuum-assisted biopsies. Only 5 (0.5%) of the 979 core biopsies were believed to have missed the malignant lesions. The false-negative rate was 3% (4 of 128 cancers) for the 14-gauge automated gun biopsies and 1% (1 of 69 cancers) for the 11-gauge vacuum-assisted biopsies. CONCLUSION: The outcomes of the sonographically guided core biopsies performed with the 11-gauge vacuum-assisted device were better than those outcomes of the biopsies performed with the 14-gauge automated gun in terms of underestimation, rebiopsy and the false negative rate, although these differences were not statistically significant.This study is supported by KISTEP and the Ministry of Science and Technology, Korea

    Is computer aided detection (CAD) cost effective in screening mammography? A model based on the CADET II study

    Get PDF
    BACKGROUND: Single reading with computer aided detection (CAD) is an alternative to double reading for detecting cancer in screening mammograms. The aim of this study is to investigate whether the use of a single reader with CAD is more cost-effective than double reading. METHODS: Based on data from the CADET II study, the cost-effectiveness of single reading with CAD versus double reading was measured in terms of cost per cancer detected. Cost (Pound (£), year 2007/08) of single reading with CAD versus double reading was estimated assuming a health and social service perspective and a 7 year time horizon. As the equipment cost varies according to the unit size a separate analysis was conducted for high, average and low volume screening units. One-way sensitivity analyses were performed by varying the reading time, equipment and assessment cost, recall rate and reader qualification. RESULTS: CAD is cost increasing for all sizes of screening unit. The introduction of CAD is cost-increasing compared to double reading because the cost of CAD equipment, staff training and the higher assessment cost associated with CAD are greater than the saving in reading costs. The introduction of single reading with CAD, in place of double reading, would produce an additional cost of £227 and £253 per 1,000 women screened in high and average volume units respectively. In low volume screening units, the high cost of purchasing the equipment will results in an additional cost of £590 per 1,000 women screened.One-way sensitivity analysis showed that the factors having the greatest effect on the cost-effectiveness of CAD with single reading compared with double reading were the reading time and the reader's professional qualification (radiologist versus advanced practitioner). CONCLUSIONS: Without improvements in CAD effectiveness (e.g. a decrease in the recall rate) CAD is unlikely to be a cost effective alternative to double reading for mammography screening in UK. This study provides updated estimates of CAD costs in a full-field digital system and assessment cost for women who are re-called after initial screening. However, the model is highly sensitive to various parameters e.g. reading time, reader qualification, and equipment cost

    Ultrasound-guided diagnostic breast biopsy methodology: retrospective comparison of the 8-gauge vacuum-assisted biopsy approach versus the spring-loaded 14-gauge core biopsy approach

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Ultrasound-guided diagnostic breast biopsy technology represents the current standard of care for the evaluation of indeterminate and suspicious lesions seen on diagnostic breast ultrasound. Yet, there remains much debate as to which particular method of ultrasound-guided diagnostic breast biopsy provides the most accurate and optimal diagnostic information. The aim of the current study was to compare and contrast the 8-gauge vacuum-assisted biopsy approach and the spring-loaded 14-gauge core biopsy approach.</p> <p>Methods</p> <p>A retrospective analysis was done of all ultrasound-guided diagnostic breast biopsy procedures performed by either the 8-gauge vacuum-assisted biopsy approach or the spring-loaded 14-gauge core biopsy approach by a single surgeon from July 2001 through June 2009.</p> <p>Results</p> <p>Among 1443 ultrasound-guided diagnostic breast biopsy procedures performed, 724 (50.2%) were by the 8-gauge vacuum-assisted biopsy technique and 719 (49.8%) were by the spring-loaded 14-gauge core biopsy technique. The total number of false negative cases (i.e., benign findings instead of invasive breast carcinoma) was significantly greater (P = 0.008) in the spring-loaded 14-gauge core biopsy group (8/681, 1.2%) as compared to in the 8-gauge vacuum-assisted biopsy group (0/652, 0%), with an overall false negative rate of 2.1% (8/386) for the spring-loaded 14-gauge core biopsy group as compared to 0% (0/148) for the 8-gauge vacuum-assisted biopsy group. Significantly more (P < 0.001) patients in the spring-loaded 14-gauge core biopsy group (81/719, 11.3%) than in the 8-gauge vacuum-assisted biopsy group (18/724, 2.5%) were recommended for further diagnostic surgical removal of additional tissue from the same anatomical site of the affected breast in an immediate fashion for indeterminate/inconclusive findings seen on the original ultrasound-guided diagnostic breast biopsy procedure. Significantly more (P < 0.001) patients in the spring-loaded 14-gauge core biopsy group (54/719, 7.5%) than in the 8-gauge vacuum-assisted biopsy group (9/724, 1.2%) personally requested further diagnostic surgical removal of additional tissue from the same anatomical site of the affected breast in an immediate fashion for a benign finding seen on the original ultrasound-guided diagnostic breast biopsy procedure.</p> <p>Conclusions</p> <p>In appropriately selected cases, the 8-gauge vacuum-assisted biopsy approach appears to be advantageous to the spring-loaded 14-gauge core biopsy approach for providing the most accurate and optimal diagnostic information.</p
    corecore