This paper invest igates the management control system choices exercised by a multinational corporation headquarters to control a newly established wholly owned foreign subsidiary located in a t ransition economy. Specifically t his paper aims to identif y what the core ch allenges of establishing and operating subsidiaries in transition economies are and how these are addressed t hrough the mult inational headquarters' management control systems. A case study is conducted of an Eastern European based subsidiary owned and controlled by a multinational corporation origi nating from South-East Asia. The challenges of operating the subsidiary in the transition economy are reported, which primarily ent ail cultu ral differences, lack of experience, lack of external integration and recruitment issues. Preliminary f indings indicate that the management control system primarily util ises personnel and results controls, which appear to address operational and management challenges
Six degrees-of-freedom prostate and lung tumor motion measurements using Kilovoltage intrafraction monitoring.
PURPOSE: Tumor positional uncertainty has been identified as a major issue that deteriorates the efficacy of radiation therapy. Tumor rotational movement, which is not well understood, can result in significant geometric and dosimetric inaccuracies. The objective of this study was to measure 6 degrees-of-freedom (6 DoF) prostate and lung tumor motion, focusing on the more novel rotation, using kilovoltage intrafraction monitoring (KIM). METHODS AND MATERIALS: Continuous kilovoltage (kV) projections of tumors with gold fiducial markers were acquired during radiation therapy for 267 fractions from 10 prostate cancer patients and immediately before or after radiation therapy for 50 fractions from 3 lung cancer patients. The 6 DoF motion measurements were determined from the individual 3-dimensional (3D) marker positions, after using methods to reject spurious and smooth noisy data, using an iterative closest point algorithm. RESULTS: There were large variations in the magnitude of the tumor rotation among different fractions and patients. Various rotational patterns were observed. The average prostate rotation angles around the left-right (LR), superior-inferior (SI), and anterior-posterior (AP) axes were 1.0 ± 5.0°, 0.6 ± 3.3°, and 0.3 ± 2.0°, respectively. For 35% of the time, the prostate rotated more than 5° about the LR axis, indicating the need for intrafractional adaptation during radiation delivery. For lung patients, the average LR, SI, and AP rotation angles were 0.8 ± 4.2°, -0.8 ± 4.5°, and 1.7 ± 3.1°, respectively. For about 30% of the time, the lung tumors rotated more than 5° around the SI axis. Respiration-induced rotation was detected in 2 of the 3 lung patients. CONCLUSIONS: The prostate and lung tumors were found to undergo rotations of more than 5° for about a third of the time. The lung tumor data represent the first 6 DoF tumor motion measured by kV images. The 6 DoF KIM method can enable rotational and translational adaptive radiation therapy and potentially reduce treatment margins
Performance assessment of a programmable five degrees-of-freedom motion platform for quality assurance of motion management techniques in radiotherapy.
Inter-fraction and intra-fraction motion management methods are increasingly applied clinically and require the development of advanced motion platforms to facilitate testing and quality assurance program development. The aim of this study was to assess the performance of a 5 degrees-of-freedom (DoF) programmable motion platform HexaMotion (ScandiDos, Uppsala, Sweden) towards clinically observed tumor motion range, velocity, acceleration and the accuracy requirements of SABR prescribed in AAPM Task Group 142. Performance specifications for the motion platform were derived from literature regarding the motion characteristics of prostate and lung tumor targets required for real time motion management. The performance of the programmable motion platform was evaluated against (1) maximum range, velocity and acceleration (5 DoF), (2) static position accuracy (5 DoF) and (3) dynamic position accuracy using patient-derived prostate and lung tumor motion traces (3 DoF). Translational motion accuracy was compared against electromagnetic transponder measurements. Rotation was benchmarked with a digital inclinometer. The static accuracy and reproducibility for translation and rotation was <0.1 mm or <0.1°, respectively. The accuracy of reproducing dynamic patient motion was <0.3 mm. The motion platform’s range met the need to reproduce clinically relevant translation and rotation ranges and its accuracy met the TG 142 requirements for SABR. The range, velocity and acceleration of the motion platform are sufficient to reproduce lung and prostate tumor motion for motion management. Programmable motion platforms are valuable tools in the investigation, quality assurance and commissioning of motion management systems in radiation oncology
Performance assessment of a programmable five degrees-of-freedom motion platform for quality assurance of motion management techniques in radiotherapy.
Inter-fraction and intra-fraction motion management methods are increasingly applied clinically and require the development of advanced motion platforms to facilitate testing and quality assurance program development. The aim of this study was to assess the performance of a 5 degrees-of-freedom (DoF) programmable motion platform HexaMotion (ScandiDos, Uppsala, Sweden) towards clinically observed tumor motion range, velocity, acceleration and the accuracy requirements of SABR prescribed in AAPM Task Group 142. Performance specifications for the motion platform were derived from literature regarding the motion characteristics of prostate and lung tumor targets required for real time motion management. The performance of the programmable motion platform was evaluated against (1) maximum range, velocity and acceleration (5 DoF), (2) static position accuracy (5 DoF) and (3) dynamic position accuracy using patient-derived prostate and lung tumor motion traces (3 DoF). Translational motion accuracy was compared against electromagnetic transponder measurements. Rotation was benchmarked with a digital inclinometer. The static accuracy and reproducibility for translation and rotation was <0.1 mm or <0.1°, respectively. The accuracy of reproducing dynamic patient motion was <0.3 mm. The motion platform’s range met the need to reproduce clinically relevant translation and rotation ranges and its accuracy met the TG 142 requirements for SABR. The range, velocity and acceleration of the motion platform are sufficient to reproduce lung and prostate tumor motion for motion management. Programmable motion platforms are valuable tools in the investigation, quality assurance and commissioning of motion management systems in radiation oncology
Determining appropriate imaging parameters for kilovoltage intrafraction monitoring: an experimental phantom study.
Kilovoltage intrafraction monitoring (KIM) utilises the kV imager during
treatment for real-time tracking of prostate fiducial markers. However, its
effectiveness relies on sufficient image quality for the fiducial tracking task.
To guide the performance characterisation of KIM under different clinically
relevant conditions, the effect of different kV parameters and patient size on
image quality, and quantification of MV scatter from the patient to the kV
detector panel were investigated in this study. Image quality was determined for
a range of kV acquisition frame rates, kV exposure, MV dose rates and patient
sizes. Two methods were used to determine image quality; the ratio of kV signal
through the patient to the MV scatter from the patient incident on the
kilovoltage detector, and the signal-to-noise ratio (SNR). The effect of patient
size and frame rate on MV scatter was evaluated in a homogeneous CIRS pelvis
phantom and marker segmentation was determined utilising the Rando phantom with
embedded markers. MV scatter incident on the detector was shown to be dependent
on patient thickness and frame rate. The segmentation code was shown to be
successful for all frame rates above 3 Hz for the Rando phantom corresponding to
a kV to MV ratio of 0.16 and an SNR of 1.67. For a maximum patient dimension less
than 36.4 cm the conservative kV parameters of 5 Hz at 1 mAs can be used to
reduce dose while retaining image quality, where the current baseline kV
parameters of 10 Hz at 1 mAs is shown to be adequate for marker segmentation up
to a patient dimension of 40 cm. In conclusion, the MV scatter component of image
quality noise for KIM has been quantified. For most prostate patients, use of KIM
with 10 Hz imaging at 1 mAs is adequate however image quality can be maintained
and imaging dose reduced by altering existing acquisition parameters
Determining appropriate imaging parameters for kilovoltage intrafraction monitoring: an experimental phantom study.
Kilovoltage intrafraction monitoring (KIM) utilises the kV imager during treatment for real-time tracking of prostate fiducial markers. However, its effectiveness relies on sufficient image quality for the fiducial tracking task. To guide the performance characterisation of KIM under different clinically relevant conditions, the effect of different kV parameters and patient size on image quality, and quantification of MV scatter from the patient to the kV detector panel were investigated in this study. Image quality was determined for a range of kV acquisition frame rates, kV exposure, MV dose rates and patient sizes. Two methods were used to determine image quality; the ratio of kV signal through the patient to the MV scatter from the patient incident on the kilovoltage detector, and the signal-to-noise ratio (SNR). The effect of patient size and frame rate on MV scatter was evaluated in a homogeneous CIRS pelvis phantom and marker segmentation was determined utilising the Rando phantom with embedded markers. MV scatter incident on the detector was shown to be dependent on patient thickness and frame rate. The segmentation code was shown to be successful for all frame rates above 3 Hz for the Rando phantom corresponding to a kV to MV ratio of 0.16 and an SNR of 1.67. For a maximum patient dimension less than 36.4 cm the conservative kV parameters of 5 Hz at 1 mAs can be used to reduce dose while retaining image quality, where the current baseline kV parameters of 10 Hz at 1 mAs is shown to be adequate for marker segmentation up to a patient dimension of 40 cm. In conclusion, the MV scatter component of image quality noise for KIM has been quantified. For most prostate patients, use of KIM with 10 Hz imaging at 1 mAs is adequate however image quality can be maintained and imaging dose reduced by altering existing acquisition parameters
Comparison of bulk milk antibody and youngstock serology screens for determining herd status for Bovine Viral Diarrhoea Virus
BACKGROUND: This paper examines the use of Bulk Milk antibody (BM Ab), Youngstock (YS) serology (Check Tests) and Bulk Milk PCR (BM PCR) for determining the presence or absence of animals persistently infected (PI) with Bovine Viral Diarrhoea Virus (BVDV) within a herd. Data is presented from 26 herds where average herd sizes were 343 and 98 animals for dairy and beef units respectively. Seventeen herds had sufficient data to analyse using Receiver Operating Characteristic (ROC) and probability curves enabling calculation of the sensitivity and specificity of BM Ab and YS Check tests for determining the presence of PI animals within herds in this dataset. RESULTS: Using BM Ab to screen a herd for the presence of PI animals, achieved a herd level sensitivity and specificity of 80.00 % (44.39–97.48 %) and 85.71 % (42.13–99.64 %) respectively (95 % confidence intervals quoted). Sensitivity and specificity of YS Check Tests at a cut off of 3/10 Ab positive YS were 81.82 % (48.22–97.72 %) and 66.67 % (22.28–95.67 %) respectively (95 % confidence interval). These results were achieved by comparing the screening tests to whole herd PI searches that took place 1–19 months after the initial screen with a mean interval of 8 months. Removal of this delay by taking BM samples on the day of a whole herd test and simulating a YS Check Test from the herd test data produced improvements in the reliability of the Check Tests. BM Ab sensitivity and specificity remained unchanged. However, the Check Test sensitivity and specificity improved to 90.9 % (58.72–99.77 %) and 100 % (54.07–100 %) respectively (95 % confidence interval) at a cut of off 2.5/10 Ab positive animals. Our limited BM PCR results identified 5/23 dairy farms with a positive BM PCR result; two contained milking PIs, two had non-milking PIs and another had no PIs identified. CONCLUSIONS: Delaying a PI search following an initial herd screen decreased the diagnostic accuracy and relevance of our results. With careful interpretation, longitudinal surveillance using a combination of the techniques discussed can successfully determine farm status and therefore allow changes in BVDV status to be detected early, thus enabling prompt action in the event of a BVDV incursion
Quantification of intrafraction prostate motion and its dosimetric effect on VMAT.
Intrafraction prostate motion degrades the accuracy of radiation therapy (RT) delivery. Whilst a number of metrics in the literature have been used to quantify intrafraction prostate motion, it has not been established whether these metrics reflect the effect of motion on the RT dose delivered to the patients. In this study, prostate motion during volumetric modulated arc therapy (VMAT) treatment of 18 patients and a total of 294 fractions was quantified through novel metrics as well as those available in the literature. The impact of the motion on VMAT dosimetry was evaluated using these metrics and dose reconstructions based on a previously validated and published method. The dosimetric impact of the motion on planning target volume (PTV) and clinical target volume (CTV) coverage and organs at risk (OARs) was correlated with the motion metrics, using the coefficient of determination (R 2 ), to evaluate their utility. Action level threshold for the prostate motion metric that best described the dosimetric impact on the PTV D95% was investigated through iterative regression analysis. The average (range) of the mean motion for the patient cohort was 1.5 mm (0.3-9.9 mm). A number of motion metrics were found to be strongly correlated with PTV D95%, the range of R 2 was 0.43-0.81. For all the motion measures, correlations with CTV D99% (range of R 2 was 0.12-0.62), rectum V65% (range of R 2 was 0.33-0.58) and bladder V65% (range of R 2 was 0.51-0.69) were not as strong as for PTV D95%. The mean of the highest 50% of motion metric was one of the best indicator of dosimetric impact on PTV D95%. Action level threshold value for this metric was found to be 3.0 mm. For an individual fraction, when the metric value was greater than 3.0 mm then the PTV D95% was reduced on average by 6.2%. This study demonstrated that several motion metrics are well correlated with the dosimetric impact (PTV D95%) of individual fraction prostate motion on VMAT delivery and could be used for treatment course adaptation
Reclaiming the political : emancipation and critique in security studies
The critical security studies literature has been marked by a shared commitment towards the politicization of security – that is, the analysis of its assumptions, implications and the practices through which it is (re)produced. In recent years, however, politicization has been accompanied by a tendency to conceive security as connected with a logic of exclusion, totalization and even violence. This has resulted in an imbalanced politicization that weakens critique. Seeking to tackle this situation, the present article engages with contributions that have advanced emancipatory versions of security. Starting with, but going beyond, the so-called Aberystwyth School of security studies, the argument reconsiders the meaning of security as emancipation by making the case for a systematic engagement with the notions of reality and power. This revised version of security as emancipation strengthens critique by addressing political dimensions that have been underplayed in the critical security literature
- …