22 research outputs found

    A FABRY-PEROT CAVITY FOR COMPTON POLARIMETRY

    Get PDF
    A new kind of Compton polarimeter using a resonant Fabry—Pe« rot cavity as a power buildup for the photon beam is proposed. A prototype of such a cavity is described, along with the results obtained in terms of source to be used in a Compton scattering polarimeter. ( 1998 Elsevier Science B.V. All rights reserved

    Josephson Coupling and Fiske Dynamics in Ferromagnetic Tunnel Junctions

    Full text link
    We report on the fabrication of Nb/AlO_x/Pd_{0.82}Ni_{0.18}/Nb superconductor/insulator/ferromagnetic metal/superconductor (SIFS) Josephson junctions with high critical current densities, large normal resistance times area products, high quality factors, and very good spatial uniformity. For these junctions a transition from 0- to \pi-coupling is observed for a thickness d_F ~ 6 nm of the ferromagnetic Pd_{0.82}Ni_{0.18} interlayer. The magnetic field dependence of the \pi-coupled junctions demonstrates good spatial homogeneity of the tunneling barrier and ferromagnetic interlayer. Magnetic characterization shows that the Pd_{0.82}Ni_{0.18} has an out-of-plane anisotropy and large saturation magnetization, indicating negligible dead layers at the interfaces. A careful analysis of Fiske modes provides information on the junction quality factor and the relevant damping mechanisms up to about 400 GHz. Whereas losses due to quasiparticle tunneling dominate at low frequencies, the damping is dominated by the finite surface resistance of the junction electrodes at high frequencies. High quality factors of up to 30 around 200 GHz have been achieved. Our analysis shows that the fabricated junctions are promising for applications in superconducting quantum circuits or quantum tunneling experiments.Comment: 15 pages, 9 figure

    Influence des conditions d'abattage et de réfrigération sur la qualité des foies gras d'oie

    No full text
    Les conditions d’abattage, d’éviscération et de refroidissement des oies gavées ont une incidence importante sur la production quantitative et qualitative des foies gras. La mise à jeun des animaux avant l’abattage est nécessaire pour préserver leur qualité sanitaire. Toutefois, un jeûne prolongé entre le dernier repas de gavage et l’abattage peut entraîner une importante diminution du poids du foie gras et une altération de sa qualité technologique par augmentation de sa fonte lipidique. Un optimum pourrait être trouvé autour de 12 h La réfrigération rapide des foies gras après l’abattage des oies gavées est nécessaire pour limiter leur fonte lipidique et ceci d’autant plus que leur qualité technologique initiale est meilleure (foies de 600 à 900 g). L’éviscération à chaud (immédiatement après l’abattage), qui permet d’isoler rapidement le foie des risques de contaminations intestinales et une réfrigération rapide hors de la carcasse, conduit à une meilleure qualité technologique des foies gras. Sa mise en oeuvre exige toutefois une parfaite maîtrise des conditions d’hygiène.Slaughtering, evisceration and cooling conditions of force-fed geese have an important impact on the quality and weight of “foie gras”. Before slaughtering, the animals must fast to maintain a low bacteriological count in the liver. However, an extended fasting period between the last force-feeding meal and time of slaughter can lead to a large loss in liver weight and also an alteration of its physical qualities by raising the melting point of the fat. The optimum fasting period is probably of the order of 12 hours. Rapid refrigeration of “foie gras”, immediatly after slaughtering the force-fed geese is necessary to limit melting of lipids. This is especially important for larger livers (livers weighing between 600 and 900 grams). Evisceration immediately after slaughtering eliminates the possibility of intestinal contamination, and quick refrigeration of the removed liver leads to a better quality liver. To implement this technique perfect control of bacteriological conditions is essential

    A CONTROL SYSTEM FOR CRYOGENIC INSTALLATIONS

    No full text
    Un système de contrôle modulaire a été développé pour l'automatisation des systèmes cryogéniques. Le système est bâti autour d'un microprocesseur ; on a développé des cartes d'interface conventionnelles et spécifiques aux applications cryogéniques. Un logiciel spécial a été écrit dans le but essentiel de permettre aux utilisateurs une écriture et une modification faciles de leur programme de contrôle. Le prototype de ce système fonctionne depuis plus d'un an. Le système est maintenant disponible commercialement ; on l'utilise et on prévoit son usage sur plusieurs installations cryogéniques dans lesquelles le laboratoire est impliqué.A modular control system has been developped for the automatization of cryogenic systems. The hardware has been built around a microprocessor ; conventional and spectific modules for cryogenic applications have been developped. A special software has also been written, the first aim of which being an easy writing and modifying ot the process control by the users. The prototype of this system has been operated for more than a year. The system is now commercially available ; it has been used and is under consideration for several cryogenic projects in which the laboratory is involved

    Propriétés mécaniques des matériaux composites (SiC/2124 et SiC/8090) soumis à des sollicitations en torsion et traction à grande vitesse et à haute température

    No full text
    Le comportement statique et dynamique en traction et en torsion des matériaux composites à matrice métallique (Al-Cu 2124 et Al-Li 8090) renforcés par des particules de carbure de silicium (SiC) a été étudié pour une gamme de température allant de 25°C à 550°C. Un dispositif de barres de Hopkinson est utilisé pour tous les essais dynamiques. Ces essais montrent pour les deux matériaux que la vitesse de déformation a une influence très nette sur la déformation maximale et moindre sur la résistance à rupture. Pour des sollicitation à des températures inférieures à 250°C, la résistance et la ductilité restent à peu près constantes. Elles diminuent à partir de températures plus élevés (> 250°C). L'incidence de la vitesse de déformation et de la température sur les comportements en traction et en torsion est la même.The static and dynamic behaviour of two metal-matrix (Al-Cu 2124 and Al-Li 8090) composite materials, reinforced by particulate SiC have been studied under torsion and tension in the temperature range 25 to 550°C. All the dynamic tests are based on the SHPB technique. The tests show that the strain rate has an obvious influence on the maximum deformation and a smaller influence on the strength at fracture for the two materials. For temperatures lower than 250°C, the strength and the ductility remain almost constant. They decrease at high temperature (> 250°C). The effects of strain rate and temperature on the behaviour is same for both tension and torsion

    Comparaison des trois génotypes RN chez le porc pour des caractères de croissance, de composition de la carcasse et de la qualité de la viande (gène majeur, gène RN)

    No full text
    "Chantier qualité spécifique "Auteurs Externes" département de Génétique animale : uniquement liaison auteur au référentiel HR-Access "International audienc
    corecore