25,673 research outputs found
Novel convolution-based signal processing techniques for an artificial olfactory mucosa
As our understanding of the human olfactory system has grown, so has our ability to design artificial devices that mimic its functionality, so called electronic noses (e-noses). This has led to the development of a more sophisticated biomimetic system known as an artificial olfactory mucosa (e-mucosa) that comprises a large distributed sensor array and artificial mucous layer. In order to exploit fully this new architecture, new approaches are required to analyzing the rich data sets that it generates. In this paper, we propose a novel convolution based approach to processing signals from the e-mucosa. Computer simulations are performed to investigate the robustness of this approach when subjected to different real-world problems, such as sensor drift and noise. Our results demonstrate a promising ability to classify odors from poor sensor signals
Independent Orbiter Assessment (IOA): Assessment of instrumental subsystem FMEA/CIL
The McDonnell Douglas Astronautics Company (MDAC) was selected in June 1986 to perform an Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL). The IOA effort first completed an analysis of the Instrumentation hardware, generating draft failure modes and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were then compared to the NASA FMEA/CIL baseline. A resolution of each discrepancy from the comparison is provided through additional analysis as required. The results of that comparison for the Orbiter Instrumentation hardware are documented. The IOA product for Instrumentation analysis consisted of 107 failure mode worksheets that resulted in 22 critical items being identified. Comparison was made to the Pre 51-L NASA baseline with 14 Post 51-L FMEAs added, which consists of 96 FMEAs and 18 CIL items. This comparison produced agreement on all but 25 FMEAs which caused differences in 5 CIL items
Study of methods for the improvement of bacterial transport media
A series of 500 transport media recipes was tested for ability to hold pure cultures of Streptococcus equisimilus, Corynebacterium equi, Neisseria perflava, and Haemophilus parainfluenzae for 21 days. Stuart Medium Base with 0.4% agar was used as the control medium for this and the other experiments in the investigation. At the end of the holding period inoculated transport media were quantitatively assayed, and the control media were assayed immediately after inoculation. Three vials of each medium were inoculated with an organism, and each vial's medium was diluted and spread on duplicate plates. Assay media for this experiment included Brain Heart Infusion,(BHIA) Tryptic Soy Agar, and BHIA with 1% Isovitalex enrichment
Combined electronic nose and tongue for a flavour sensing system
We present a novel, smart sensing system developed for the flavour analysis of liquids. The system comprises both a so-called "electronic tongue" based on shear horizontal surface acoustic wave (SH-SAW) sensors analysing the liquid phase and a so-called "electronic nose" based on chemFET sensors analysing the gaseous phase. Flavour is generally understood to be the overall experience from the combination of oral and nasal stimulation and is principally derived from a combination of the human senses of taste (gustation) and smell (olfaction). Thus, by combining two types of microsensors, an artificial flavour sensing system has been developed. Initial tests conducted with different liquid samples, i.e. water, orange juice and milk (of different fat content), resulted in 100% discrimination using principal components analysis; although it was found that there was little contribution from the electronic nose. Therefore further flavour experiments were designed to demonstrate the potential of the combined electronic nose/tongue flavour system. Consequently, experiments were conducted on low vapour pressure taste-biased solutions and high vapour pressure, smell-biased solutions. Only the combined flavour analysis system could achieve 100% discrimination between all the different liquids. We believe that this is the first report of a SAW-based analysis system that determines flavour through the combination of both liquid and headspace analysis
Space Transportation Materials and Structures Technology Workshop. Volume 1: Executive summary
The workshop was held to provide a forum for communication within the space materials and structures technology developer and user communities. Workshop participants were organized into a Vehicle Technology Requirements session and three working panels: Materials and Structures Technologies for Vehicle Systems; Propulsion Systems; and Entry Systems. The goals accomplished were (1) to develop important strategic planning information necessary to transition materials and structures technologies from lab research programs into robust and affordable operational systems; (2) to provide a forum for the exchange of information and ideas between technology developers and users; and (3) to provide senior NASA management with a review of current space transportation programs, related subjects, and specific technology needs. The workshop thus provided a foundation on which a NASA and industry effort to address space transportation materials and structures technologies can grow
Conceptual design and analysis of a large antenna utilizing electrostatic membrane management
Conceptual designs and associated technologies for deployment 100 m class radiometer antennas were developed. An electrostatically suspended and controlled membrane mirror and the supporting structure are discussed. The integrated spacecraft including STS cargo bay stowage and development were analyzed. An antenna performance evaluation was performed as a measure of the quality of the membrane/spacecraft when used as a radiometer in the 1 GHz to 5 GHz region. Several related LSS structural dynamic models differing by their stiffness property (and therefore, lowest modal frequencies) are reported. Control system whose complexity varies inversely with increasing modal frequency regimes are also reported. Interactive computer-aided-design software is discussed
A polynomial training algorithm for calculating perceptrons of optimal stability
Recomi (REpeated COrrelation Matrix Inversion) is a polynomially fast
algorithm for searching optimally stable solutions of the perceptron learning
problem. For random unbiased and biased patterns it is shown that the algorithm
is able to find optimal solutions, if any exist, in at worst O(N^4) floating
point operations. Even beyond the critical storage capacity alpha_c the
algorithm is able to find locally stable solutions (with negative stability) at
the same speed. There are no divergent time scales in the learning process. A
full proof of convergence cannot yet be given, only major constituents of a
proof are shown.Comment: 11 pages, Latex, 4 EPS figure
A low cost MEMS based NDIR system for the monitoring of carbon dioxide in breath analysis at ppm levels
The molecules in our breath can provide a wealth of information about the health and well-being of a person. The level of carbon dioxide (CO2) is not only a sign of life but also when combined with the level of exhaled oxygen provides valuable health information in the form of our metabolic rate. We report upon the development of a MEMS-based non-dispersive infrared CO2 sensor for inclusion in a hand held portable breath analyser. Our novel sensor system comprises a thermopile detector and low power MEMS silicon on insulator (SOI) wideband infrared (IR) emitter. A lock-in amplifier design permits a CO2 concentration of 50 ppm to be detected on gas bench rig. Different IR path lengths were studied with gases in dry and humid (25% and 50% RH) in order to design a sensor suitable for detecting CO2 in breath with concentrations in the range of 4 to 5%. A breath analyser was constructed from acetal and in part 3D printed with a side-stream sampling mechanism and tested on a range of subjects with two data-sets presented here. The performance of the novel MEMS based sensor was validated using a reference commercial breath-by-breath sensor and produced comparable results and gave a response time of 1.3 s. Further work involves the detection of other compounds on breath for further metabolic analysis and reducing the overall resolution of our MEMS sensor system from ca. 250 ppm to 10 ppm
- …