79 research outputs found

    Long Term outcomes of percutaneous atrial fibrillation ablation in patients with continuous monitoring

    Get PDF
    INTRODUCTION: There is limited data using continuous monitoring to assess outcomes of atrial fibrillation (AF) ablation. This study assessed long-term outcomes of AF ablation in patients with implantable cardiac devices. METHODS: 207 patients (mean age 68.1 ± 9.5, 50.3% men) undergoing ablation for symptomatic AF were followed up for a mean period of 924.5 ± 636.7 days. Techniques included The Pulmonary Vein Ablation Catheter (PVAC) (59.4%), cryoablation (17.4%), point by point (14.0%) and The Novel Irrigated Multipolar Radiofrequency Ablation Catheter (nMARQ) (9.2%). RESULTS: 130 (62.8%) patients had paroxysmal AF (PAF) and 77 (37.2%) persistent AF. First ablation and repeat ablation reduced AF burden significantly (relative risk 0.91, [95% CI 0.89 to 0.94]; P <0.0001 and 0.90, [95% CI, 0.86-0.94]; P <0.0001). Median AF burden in PAF patients reduced from 1.05% (interquartile range [IQR], 0.1%-8.70%) to 0.10% ([IQR], 0%-2.28%) at one year and this was maintained out to four-years. Persistent AF burden reduced from 99.9% ([IQR], 51.53%-100%) to 0.30% ([IQR], 0%-77.25%) at one year increasing to 87.3% ([IQR], 4.25%-100%) after four years. If a second ablation was required, point-by-point ablation achieved greater reduction in AF burden (relative risk, 0.77 [95% CI, 0.65-0.91]; P <0.01). CONCLUSION: Ablation reduces AF burden both acutely and in the long-term. If a second ablation was required the point-by-point technique achieved greater reductions in AF burden than "single-shot" technologies. Persistent AF burden increased to near pre ablation levels by year 4 suggesting a different mechanism from PAF patients where this increase did not occur

    A preliminary assessment of the effects of ATI-2042 in subjects with paroxysmal atrial fibrillation using implanted pacemaker methodology

    Get PDF
    Aims ATI-2042 (budiodarone) is a chemical analogue of amiodarone with a half life of 7 h. It is electrophysiologically similar to amiodarone, but may not have metabolic and interaction side effects. The sophisticated electrocardiograph logs of advanced DDDRP pacemakers were used to monitor the efficacy of ATI-2042. The aim of this study was to determine the preliminary efficacy and safety of ATI-2042 in patients with paroxsymal atrial fibrillation (PAF) and pacemakers. Methods and results Six women with AF burden (AFB) between 1 and 50% underwent six sequential 2-week study periods. Patients received 200 mg bid of ATI-2042 during Period 2 (p2), 400 mg bid during p3, 600 mg bid during p4, 800 mg bid during p5, and no drug during baseline and washout (p1 and p6). Pacemaker data for the primary outcome measure AFB were downloaded during each period. Mean AFB decreased between baseline and all doses: AFB at baseline (SD) was 20.3 ± 14.6% and mean AFB at 200 mg bid was 5.2 ± 4.2%, at 400 mg bid 5.2 ± 5.2%, at 600 mg bid 2.8 ± 3.4%, and at 800 mg bid 1.5 ± 0.5%. The mean reductions in AFB at all doses of ATI-2042 were statistically significant (P < 0.005). Atrial fibrillation burden increased in washout. Atrial fibrillation episodes tended to increase with ATI-2042, but this was offset by substantial decreases in episode duration. ATI-2042 was generally well tolerated. Conclusion ATI-2042 effectively reduced AFB over all doses studied by reducing mean episode duration. A large-scale study will be required to confirm this effect

    Irish Cardiac Society - Proceedings of the Annual General Meeting held November 1993

    Get PDF
    • …
    corecore