1,497 research outputs found
Tunable fibre-coupled multiphoton microscopy with a negative curvature fibre
Negative curvature fibre (NCF) guides light in its core by inhibiting the coupling of core and cladding modes. In this work, an NCF was designed and fabricated to transmit ultrashort optical pulses for multiphoton microscopy with low group velocity dispersion (GVD) at 800 nm. Its attenuation was measured to be <0.3 dB m(-1) over the range 600-850 nm and the GVD was -180 ± 70 fs(2) m(-1) at 800 nm. Using an average fibre output power of ∼20 mW and pulse repetition rate of 80 MHz, the NCF enabled pulses with a duration of <200 fs to be transmitted through a length of 1.5 m of fibre over a tuning range of 180 nm without the need for dispersion compensation. In a 4 m fibre, temporal and spectral pulse widths were maintained to within 10% of low power values up to the maximum fibre output power achievable with the laser system used of 278 mW at 700 nm, 808 mW at 800 nm and 420 mW at 860 nm. When coupled to a multiphoton microscope, it enabled imaging of ex vivo tissue using excitation wavelengths from 740 nm to 860 nm without any need for adjustments to the set-up
Measurements of the Shape of Sand Ripples
Laboratory experiments have been conductef. for determining what would be the correct selection of acoustic devices for measuring the shape of sand ripples. The results reveal that a toneburst type signal generator with I or 2 watts will be sufficient to drive the transducer. A transducer with focus and reasonable size would be the best choice. While measuring, the ratio of measuring distance (between the transducer and sea floor) and the transducer\u27s focus length should be maintained at a ratio between 90% and II 0% for best results
Correction Approach for Delta Function Convolution Model Fitting of Fluorescence Decay Data in the Case of a Monoexponential Reference Fluorophore
A correction is proposed to the Delta function convolution method (DFCM) for fitting a multiexponential decay model to time-resolved fluorescence decay data using a monoexponential reference fluorophore. A theoretical analysis of the discretised DFCM multiexponential decay function shows the presence an extra exponential decay term with the same lifetime as the reference fluorophore that we denote as the residual reference component. This extra decay component arises as a result of the discretised convolution of one of the two terms in the modified model function required by the DFCM. The effect of the residual reference component becomes more pronounced when the fluorescence lifetime of the reference is longer than all of the individual components of the specimen under inspection and when the temporal sampling interval is not negligible compared to the quantity (τ(R)(−1) – τ(−1))(−1), where τ(R) and τ are the fluorescence lifetimes of the reference and the specimen respectively. It is shown that the unwanted residual reference component results in systematic errors when fitting simulated data and that these errors are not present when the proposed correction is applied. The correction is also verified using real data obtained from experiment
Fluid Driven by Tangential Velocity and Shear Stress: Mathematical Analysis, Numerical Experiment, and Implication to Surface Flow
This paper investigates behaviors of flows driven by tangential velocity and shear stress on their boundaries such as solid walls and water surfaces. In a steady flow between two parallel plates with one of them in motion, analytic solutions are the same when a velocity and a shear stress boundary condition are applied on the moving plate. For an unsteady, impulsively started flow, however, analysis shows that solutions for velocity profiles as well as energy transferring and dissipation are different under the two boundary conditions. In an air-water flow, if either a velocity or a stress condition is imposed at the air-water interface, the problem becomes ill-posed because it has multiple solutions. Only when both of the conditions are specified, it will have a unique solution. Numerical simulations for cavity flows are made to confirm the theoretical results; a tangential velocity and a shear stress boundary condition introduce distinct flows if one considers an unsteady flow, whereas the two conditions lead to a same solution if one simulates a steady flow. The results in this paper imply that discretion is needed on selection of boundary conditions to approximate forcing on fluid boundaries such as wind effects on surfaces of coastal ocean waters
Three Dimensional Hydrodynamic Modeling Study, Craney Island eastward expansion, lower James River and Elizabeth River, Virginia
The Craney Island Eastward Expansion Hydrodynamic Model Study was conducted in three phases: 1) model calibration and verification for the Elizabeth River, 2) model testing of four Craney Island expansion options using single variable runs (using a single variable, tidal range, for model input), 3) model testing of two expansion options using historical runs (using multiple variables in real time for model input). The expansion option designs were evaluated for both global and local hydrodynamic change through simulation comparisons with the Base Case condition
- …