    Neuro-vestibular Examination During and Following Spaceflight

    Get PDF
    Adaptation to microgravity during spaceflight causes neurological disturbances that are either directly or indirectly mediated by the vestibular system. These disturbances could include space motion sickness, spatial disorientation, cognitive impairment, as well as changes in head-eye coordination, vestibulo-ocular reflex, and strategies for controlling posture and locomotion. It seems that otolith-mediated reflex gain adapts rapidly over time during spaceflight and after landing. However, animal studies have shown that structural modifications of the vestibular sensory apparatus develop during long-duration spaceflight. To date, no studies have characterized the severity of vestibular syndromes experienced by astronauts as a function of the duration of spaceflight, or whether the effects are caused by changes at the peripheral end organs, midbrain, cerebellum, or vestibular cortex

    Capability of C-band SAR for operational wetland monitoring at high latitudes

    Get PDF
    Wetlands store large amounts of carbon, and depending on their status and type, they release specific amounts of methane gas to the atmosphere. The connection between wetland type and methane emission has been investigated in various studies and utilized in climate change monitoring and modelling. For improved estimation of methane emissions, land surface models require information such as the wetland fraction and its dynamics over large areas. Existing datasets of wetland dynamics present the total amount of wetland (fraction) for each model grid cell, but do not discriminate the different wetland types like permanent lakes, periodically inundated areas or peatlands. Wetland types differently influence methane fluxes and thus their contribution to the total wetland fraction should be quantified. Especially wetlands of permafrost regions are expected to have a strong impact on future climate due to soil thawing. In this study ENVISAT ASAR Wide Swath data was tested for operational monitoring of the distribution of areas with a long-term SW near 1 (hSW) in northern Russia (SW = degree of saturation with water, 1 = saturated), which is a specific characteristic of peatlands. For the whole northern Russia, areas with hSW were delineated and discriminated from dynamic and open water bodies for the years 2007 and 2008. The area identified with this method amounts to approximately 300,000 km2 in northern Siberia in 2007. It overlaps with zones of high carbon storage. Comparison with a range of related datasets (static and dynamic) showed that hSW represents not only peatlands but also temporary wetlands associated with post-forest fire conditions in permafrost regions. Annual long-term monitoring of change in boreal and tundra environments is possible with the presented approach. Sentinel-1, the successor of ENVISAT ASAR, will provide data that may allow continuous monitoring of these wetland dynamics in the future complementing global observations of wetland fraction

    Modification of the Passive Vestibulo-Ocular Reflex During and After Short-Duration Spaceflight

    Get PDF
    The vestibulo-ocular reflex (VOR) is mediated by integration of canal and otolith inputs to generate compensatory eye movements during head movements. We hypothesized that adaptive change in vestibular processing of gravitoinertial cues would be reflected by plane specific modification of the VOR during passive whole-body rotation during and after spaceflight. Using a repeated measures design, the VOR was assessed in four payload crewmembers in yaw, pitch and roll planes during multiple sessions before, during and after an 8 day orbital mission (STS-42). Rotation was about an earth-vertical axis during ground tests, with the head located off-axis by up to 45cm during pitch and roll rotation (peak acceleration less than 0.2g). The motion profiles included sum-of-sinusoids between 0.02 - 1.39 Hz (yaw), single sinusoids between 0.05-1.25 Hz (yaw and pitch) and velocity steps (yaw, pitch and roll). Eye movements were recorded with both video and electro-oculographic techniques. As expected, VOR gain changes were greater in pitch than in yaw. During pitch rotation, there was a progressive shift in the axis of eye movements during the flight, which was also present during the early post-flight period. This increased horizontal component during pitch, most prevalent at 0.2 Hz, was interpreted as an increase in a translational vergence response elicited during eccentric rotation as subjects imagined a wall fixed target. There was also an increased horizontal component during the eccentric roll step runs performed on flight day 7. These results are consistent with a frequency-dependent increase in otolith-mediated translational VOR responses following adaptation to microgravity. We conclude that the adaptive changes in the VOR are likely to be greatest in the frequency range where there is a cross-over of otolith-mediated tilt and translation responses

    Subjective Straight Ahead Orientation in Microgravity

    Get PDF
    This joint ESA NASA study will address adaptive changes in spatial orientation related to the subjective straight ahead and the use of a vibrotactile sensory aid to reduce perceptual errors. The study will be conducted before and after long-duration expeditions to the International Space Station (ISS) to examine how spatial processing of target location is altered following exposure to microgravity. This study addresses the sensorimotor research gap to "determine the changes in sensorimotor function over the course of a mission and during recovery after landing.

    Tilt and Translation Motion Perception during Off Vertical Axis Rotation

    Get PDF
    The effect of stimulus frequency on tilt and translation motion perception was studied during constant velocity off-vertical axis rotation (OVAR), and compared to the effect of stimulus frequency on eye movements. Fourteen healthy subjects were rotated in darkness about their longitudinal axis 10deg and 20deg off-vertical at 0.125 Hz, and 20deg offvertical at 0.5 Hz. Oculomotor responses were recorded using videography, and perceived motion was evaluated using verbal reports and a joystick with four degrees of freedom (pitch and roll tilt, mediallateral and anteriorposterior translation). During the lower frequency OVAR, subjects reported the perception of progressing along the edge of a cone. During higher frequency OVAR, subjects reported the perception of progressing along the edge of an upright cylinder. The modulation of both tilt recorded from the joystick and ocular torsion significantly increased as the tilt angle increased from 10deg to 20deg at 0.125 Hz, and then decreased at 0.5 Hz. Both tilt perception and torsion slightly lagged head orientation at 0.125 Hz. The phase lag of torsion increased at 0.5 Hz, while the phase of tilt perception did not change as a function of frequency. The amplitude of both translation perception recorded from the joystick and horizontal eye movements was negligible at 0.125 Hz and increased as a function of stimulus frequency. While the phase lead of horizontal eye movements decreased at 0.5 Hz, the phase of translation perception did not vary with stimulus frequency and was similar to the phase of tilt perception during all conditions. During dynamic linear acceleration in the absence of other sensory input (canal, vision) a change in stimulus frequency alone elicits similar changes in the amplitude of both self motion perception and eye movements. However, in contrast to the eye movements, the phase of both perceived tilt and translation motion is not altered by stimulus frequency. We conclude that the neural processing to distinguish tilt and translation linear acceleration stimuli differs between eye movements and motion perception

    Balance in Astronauts Performing Jumps, Walking and Quiet Stance Following Spaceflight

    Get PDF
    Introduction: Both balance and locomotor ataxia is severe in astronauts returning from spaceflight with serious implications for unassisted landings. As a part of an ongoing effort to demonstrate the functional significance of the postflight ataxia problem our laboratory has evaluated jumping, walking heel-to-toe and quite stance balance immediately following spaceflight. Methods: Six astronauts from 12-16 day flights and three from 6-month flights were asked to perform three self-initiated two-footed jumps from a 30-cm-high platform, walking for 10 steps (three trials) placing the feet heel to toe in tandem, arms folded across the chest and the eyes closed, and lastly, recover from a simulated fall by standing from a prone position on the floor and with eyes open maintain a quiet stance for 3 min with arms relaxed along the side of the body and feet comfortably positioned on a force plate. Crewmembers were tested twice before flight, on landing day (short-duration), and days 1, 6, and 30 following all flight durations. Results/Conclusions: Many of astronauts tested fell on their first postflight jump but recovered by the third jump showing a rapid learning progression. Changes in take-off strategy were clearly evident in duration of time in the air between the platform and the ground (significant reduction in time to land), and also in increased asymmetry in foot latencies on take-off postflight. During the tandem heel-to-toe walking task there was a significant decrease in percentage of correct steps on landing day (short-duration crew) and on first day following landing (long-duration) with only partial recovery the following day. Astronauts for both short and long duration flight times appeared to be unaware of foot position relative to their bodies or the floor. During quite stance most of crewmembers tested exhibited increased stochastic activity (larger short-term COP diffusion coefficients postflight in all planes and increases in mean sway speed)

    Simultaneous Separation and Detection of Cations and Anions Ion a Microfluidic Device with Suppressed Electroosmotic Flow and a Single Injection Point

    Get PDF
    A rapid and simultaneous separation of cationic and anionic peptides and proteins in a glass microfluidic device that has been covalently modified with a neutral poly(ethylene glycol) (PEG) coating to minimize protein adsorption is presented. The features of the device allow samples that contain both anions and cations to be introduced from a central flow stream and separated in different channels with different outlets—all in the presence of low electroosmotic flow (EOF) imparted by the PEG coating. The analytes are electrophoretically extracted from a central hydrodynamic stream and electrophoretically separated in two different channels, in which pressure driven flow has been suppressed through the use of hydrodynamic restrictors. Having different outlets for the electrophoretic separation channels that are spatially separated from the injection enables coupling with further downstream functionalities or off-chip detection, such as mass spectrometry. A plug of charged analyte is hydrodynamically pumped to the sampling intersection and anions from the plug migrate electrophoretically toward the anode in one channel while cations migrate toward the cathode in the other channel due to suppressed EOF from the PEG coating. The separations presented here required less than a minute to complete and produced average separation efficiencies of up to about 3,500 plates from a separation length of 2 cm. The extraction efficiency of both cations and anions from the hydrodynamic stream is determined experimentally and compared with a previously reported model that was used to determine anion extraction efficiency. The extraction efficiency is determined to be 87% and 98% for the two sample mixtures analyzed, and the values predicted by the model are within 3.5% of the experimental data. It is anticipated that this basic approach for simultaneous separation of anions and cations with reduced EOF will be integrated into larger microfluidic systems because the design provides separate outlets that can feed downstream processes or linked to off-chip detection

    A Countermeasure for Space Motion Sickness

    Get PDF
    Overall, the results obtained in both the U.S. and the Russian space programs indicate that most space crews will experience some symptoms of motion sickness (MS) causing significant impact on the operational objectives that must be accomplished to assure mission success. At this time the primary countermeasure for MS requires the administration of Promethazine. Promethazine is not a benign drug, and is most frequently administered just prior to the sleep cycle to prevent its side effects from further compromising mission objectives. Clearly other countermeasures for SMS must be developed. Currently the primary focus is on two different technologies: (1) developing new and different pharmacological compounds with less significant side effects, (2) preflight training. The primary problem with all of these methods for controlling MS is time. New drugs that may be beneficial are years from testing and development, and preflight training requires a significant investment of crew time during an already intensive pre-launch schedule. Granted, motion sickness symptoms can be minimized with either of the two methods detailed above, however, it may be possible to develop a countermeasure that does not require either extensive adaptation time or exposure to motion sickness. Approximately 25 years ago Professor Geoffrey Melvill Jones presented his work on adaptation of the vestibuloocular reflex (VOR) using optically reversed vision (left-right prisms) during head rotations in the horizontal plane. It was of no surprise that most subjects experienced motion sickness while wearing the optically reversing prisms. However, a serendipitous finding emerged during this research showing that the same subjects did not experience motion sickness symptoms when wearing the reversing prisms under stroboscopic illumination. The mechanism, by which this side-effect was believed to have occurred, is not clearly understood. However, the fact that no motion sickness was ever noted, suggests the possibility of producing functionally useful adaptation during space flight without the penalty of disabling motion sickness by controlling the rate of the adaptive process by means of an appropriate stroboscopically presented environment. After several recent meetings with Professor Melvill Jones, we were encouraged to repeat the motion sickness portions of his and Mandl's 1981 stroboscopic experiment. In conducting this experiment we used a randomized cross-over design where subjects were randomly assigned to either a stroboscopic flash or no strobe for their first exposure in the experimental design. Twenty subjects (19 subjects completed the study) read a short passage from Treasure Island mounted on the wall approximately 1 m from their eyes while wearing left-right reversing prisms. The strobe on time of 3 microseconds and flash frequency of 4 Hz was set to equal that used in the original study. Motion sickness was scored using a modified Miller and Graybiel scale that we constructed to include symptoms that may be elicited under conditions where reversing prisms are worn. On this scale a score of 5 represented Malaise IIa (mild motion sickness) and a score of 8 or above is approaching frank sickness. Symptoms were tracked and recorded every 5 min during the task. Testing was limited to 30 min unless the subject had reached the MIIa score, at which time the test was terminated. Performance under stroboscopic illumination was significantly better than when the subjects read under normal room illumination while wearing the left-right reversing prisms. Based on these results we developed a goggle system using LCD material that can be strobed. To evaluate the effectiveness of stroboscopic goggles we tested an additional 9 subjects in addition to retesting 10 used in the stroboscopic pilot study described above. These 19 subjects wore a pair of strobing LCD goggles that could be cycled at 4 Hz. These subjects wore the goggles while also wearing left-right reversg prisms. Results while wearing the goggles showed that none of the 19 subjects scored at the MIIa level on the motion sickness rating scale. When the goggles did not flash (no strobe), 11 of the 19 developed symptoms above the MIIa criteria. As a countermeasure the goggles seem to be effective, even with an on time of 10 msec (time the goggles are clear). We have also collected anecdotal data, from our personnel in the Neuroscience Laboratory at the Johnson Space Center, suggesting that the goggles may effective in preventing carsickness