130 research outputs found

    The passage of the bomb radiocarbon pulse into the Pacific Ocean

    Get PDF
    Author Posting. © Arizona Board of Regents on behalf of the University of Arizona, 2010. This article is posted here by permission of Dept. of Geosciences, University of Arizona for personal use, not for redistribution. The definitive version was published in Radiocarbon 52 (2010): 1182-1190.We report and compare radiocarbon observations made on 2 meridional oceanographic sections along 150°W in the South Pacific in 1991 and 2005. The distributions reflect the progressive penetration of nuclear weapons-produced 14C into the oceanic thermocline. The changes over the 14 yr between occupations are demonstrably large relative to any possible drift in our analytical standardization. The computed difference field based on the gridded data in the upper 1600 m of the section exhibits a significant decrease over time (approaching 40 to 50‰ in Δ14C) in the upper 200–300 m, consistent with the decadal post-bomb decline in atmospheric 14C levels. A strong positive anomaly (increase with time), centered on the low salinity core of the Antarctic Intermediate Water (AAIW), approaches 50–60‰ in Δ14C, a clear signature of the downstream evolution of the 14C transient in this water mass. We use this observation to estimate the transit time of AAIW from its “source region” in the southeast South Pacific and to compute the effective reservoir age of this water mass. The 2 sections show small but significant changes in the abyssal 14C distributions. Between 1991 and 2005, Δ14C has increased by 9‰ below 2000 m north of 55°S. This change is accompanied overall by a modest increase in salinity and dissolved oxygen, as well as a slight decrease in dissolved silica. Such changes are indicative of greater ventilation. Calculation of “phosphate star” also indicates that this may be due to a shift from the Southern Ocean toward North Atlantic Deep Water as the ventilation source of the abyssal South Pacific.This work was performed under National Science Foundation Grant number OCE-0223434 as well as a cooperative agreement with NSF (most recently OCE-0228996)

    Radiocarbon dating of the historic Livingstone Tree at Chiramba, Mozambique

    Get PDF
    Author Posting. © Studia Chemia, 2020. Studia Universitatis Babes-Bolyai Seria Chemia is an Open Access Journal (read, download, copy, distribute, print for research use, search, or link to the full texts of articles). The definitive version was published in Studia Universitatis Babes-Bolyai, Seria Chemia 65, no. 3 (2020): 149-156, doi:10.24193/subbchem.2020.3.11.The article reports the AMS (accelerator mass spectrometry) radiocarbon dating results of the Livingstone Tree, a large African baobab on the right bank of the Zambezi, near Chiramba, Mozambique. In 1858, David Livingstone, who discovered the baobab, carved his monogram on the walls of its inner cavity. In 1996, the historic baobab was uprooted when a cyclone struck the area. Several wood fragments were extracted from the remains of the toppled tree. Five samples which originate from these fragments were subsequently dated by radiocarbon. The oldest sample had a radiocarbon date of 1598 ± 17 BP, that corresponded in 1996 to a calibrated age of 1490 ± 35 calendar years. According to this value, the Livingstone Tree at Chiramba becomes one of the oldest known African baobabs, with an age of over 1500 years. The Livingstone Tree had a closed ring-shaped structure, that consisted of 4 fused stems around a false cavity and also 2 additional stems outside the ring.The research was funded by the Romanian Ministry of National Education CNCS-UEFISCDI under grants PN-II-ID-PCE-2013-76 and PN-III-P4-ID-PCE-2016-0776, Nr. 90/2017

    Optimizing a microwave gas ion source for continuous-flow accelerator mass spectrometry

    Get PDF
    Author Posting. © The Author(s), 2011. This is the author's version of the work. It is posted here by permission of American Institute of Physics for personal use, not for redistribution. The definitive version was published in Review of Scientific Instruments 83 (2012): 02B304, doi:10.1063/1.3656408.A 2.45 GHz microwave ion source coupled with a magnesium charge exchange canal (CxC) has been successfully adapted to a large acceptance radiocarbon accelerator mass spectrometry system at the National Ocean Sciences AMS Facility (NOSAMS), Woods Hole Oceanographic Institution. CO2 samples from various preparation sources are injected into the source through a glass capillary at 370 ”l/min. Routine system parameters are about 120 - 140 ”A of negative 12C current after the CxC, leading to about 400 14C counts per second for a modern sample and implying a system efficiency of 0.2%. While these parameters already allow us to perform high quality AMS analyses on large samples, we are working on ways to improve the output of the ion source regarding emittance and efficiency. Modeling calculations suggest modifications in the extraction triode geometry, shape and size of the plasma chamber could improve emittance and hence ion transport efficiency. Results of experimental tests of these modifications are presented.This work has been supported by the US National Science Foundation through Cooperative Agreement OCE-0753487

    Software development for continuous-gas-flow AMS

    Get PDF
    Author Posting. © Elsevier B.V., 2008. This is the author's version of the work. It is posted here by permission of Elsevier B.V. for personal use, not for redistribution. The definitive version was published in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms 266 (2008): 2233-2237, doi:10.1016/j.nimb.2008.03.001.The National Ocean Sciences Accelerator Mass Spectrometry (NOSAMS) Facility at Woods Hole Oceanographic Institution is presently completing installation of a novel continuous-flow AMS system. A multi-year development of an AMS microwave gas ion source in collaboration with Atomic Energy Canada Limited (AECL), Chalk River, has preceded this final step of an implementation that is expected to add a new dimension to 14C AMS. National Instruments, NIM, and CAMAC modules have been programmed with LabVIEW on a Windows XP platform to form the basis for data acquisition. In this paper we discuss possible applications and include simulations of expected data acquisition scenarios like real-time AMS analysis of chromatograms. Particular attention is given to issues of synchronization between rapidly changing input amplitudes and signal processing cycles in hardware and software.This work is supported by the United States National Science Foundation under Cooperative Agreement OCE-0228996

    A continuous-flow gas chromatography 14C accelerator mass spectrometry system

    Get PDF
    Author Posting. © Arizona Board of Regents on behalf of the University of Arizona, 2010. This article is posted here by permission of Dept. of Geosciences, University of Arizona for personal use, not for redistribution. The definitive version was published in Radiocarbon 52 (2010): 295-300.Gas-accepting ion sources for radiocarbon accelerator mass spectrometry (AMS) have permitted the direct analysis of CO2 gas, eliminating the need to graphitize samples. As a result, a variety of analytical instruments can be interfaced to an AMS system, processing time is decreased, and smaller samples can be analyzed (albeit with lower precision). We have coupled a gas chromatograph to a compact 14C AMS system fitted with a microwave ion source for real-time compoundspecific 14C analysis. As an initial test of the system, we have analyzed a sample of fatty acid methyl esters and biodiesel. Peak shape and memory was better then existing systems fitted with a hybrid ion source while precision was comparable. 14C/12C ratios of individual components at natural abundance levels were consistent with those determined by conventional methods. Continuing refinements to the ion source are expected to improve the performance and scope of the instrument.This work was performed under NSF Cooperative Agreement Number OCE-0753487

    Feedback-Driven Radiology Exam Report Retrieval with Semantics

    Get PDF
    Clinical documents are vital resources for radiologists to have a better understanding of patient history. The use of clinical documents can complement the often brief reasons for exams that are provided by physicians in order to perform more informed diagnoses. With the large number of study exams that radiologists have to perform on a daily basis, it becomes too time-consuming for radiologists to sift through each patient\u27s clinical documents. It is therefore important to provide a capability that can present contextually relevant clinical documents, and at the same time satisfy the diverse information needs among radiologists from different specialties. In this work, we propose a knowledge-based semantic similarity approach that uses domain-specific relationships such as part-of along with taxonomic relationships such as is-a to identify relevant radiology exam records. Our approach also incorporates explicit relevance feedback to personalize radiologists information needs. We evaluated our approach on a corpus of 6,265 radiology exam reports through study sessions with radiologists and demonstrated that the retrieval performance of our approach yields an improvement of 5% over the baseline. We further performed intra-class and inter-class similarities using a subset of 2,384 reports spanning across 10 exam codes. Our result shows that intra-class similarities are always higher than the inter-class similarities and our approach was able to obtain 6% percent improvement in intra-class similarities against the baseline. Our results suggest that the use of domain-specific relationships together with relevance feedback provides a significant value to improve the accuracy of the retrieval of radiology exam reports

    Mean-field calculations of quasi-elastic responses in 4He

    Full text link
    We present calculations of the quasi-elastic responses functions in 4He based upon a mean-field model used to perform analogous calculations in heavier nuclei. The meson exchange current contribution is small if compared with the results of calculations where short-range correlations are explicitly considered. It is argued that the presence of these correlations in the description of the nuclear wave functions is crucial to make meson exchange current effects appreciable.Comment: uuencoded file containing 7 LaTex peges plus 3 ps figures. To be published in Physical Review

    Rapid radiocarbon (14C) analysis of coral and carbonate samples using a continuous-flow accelerator mass spectrometry (CFAMS) system

    Get PDF
    Author Posting. © American Geophysical Union, 2011. This article is posted here by permission of American Geophysical Union for personal use, not for redistribution. The definitive version was published in Paleoceanography 26 (2011): PA4212, doi:10.1029/2011PA002174.Radiocarbon analyses of carbonate materials provide critical information for understanding the last glacial cycle, recent climate history and paleoceanography. Methods that reduce the time and cost of radiocarbon (14C) analysis are highly desirable for large sample sets and reconnaissance type studies. We have developed a method for rapid radiocarbon analysis of carbonates using a novel continuous-flow accelerator mass spectrometry (CFAMS) system. We analyzed a suite of deep-sea coral samples and compared the results with those obtained using a conventional AMS system. Measurement uncertainty is <0.02 Fm or 160 Ryr for a modern sample and the mean background was 37,800 Ryr. Radiocarbon values were repeatable and in good agreement with those from the conventional AMS system. Sample handling and preparation is relatively simple and the method offered a significant increase in speed and cost effectiveness. We applied the method to coral samples from the Eastern Pacific Ocean to obtain an age distribution and identify samples for further analysis. This paper is intended to update the paleoceanographic community on the status of this new method and demonstrate its feasibility as a choice for rapid and affordable radiocarbon analysis.This work was performed under NSF Cooperative Agreement OCE‐0753487, and also NSF‐OPP awards 0636787 and 0944474

    Technical Challenges in the Clinical Application of Radiomics.

    Get PDF
    Radiomics is a quantitative approach to medical image analysis targeted at deciphering the morphologic and functional features of a lesion. Radiomic methods can be applied across various malignant conditions to identify tumor phenotype characteristics in the images that correlate with their likelihood of survival, as well as their association with the underlying biology. Identifying this set of characteristic features, called tumor signature, holds tremendous value in predicting the behavior and progression of cancer, which in turn has the potential to predict its response to various therapeutic options. We discuss the technical challenges encountered in the application of radiomics, in terms of methodology, workflow integration, and user experience, that need to be addressed to harness its true potential

    Quasielastic 12C(e,e'p) Reaction at High Momentum Transfer

    Full text link
    We measured the 12C(e,e'p) cross section as a function of missing energy in parallel kinematics for (q,w) = (970 MeV/c, 330 MeV) and (990 MeV/c, 475 MeV). At w=475 MeV, at the maximum of the quasielastic peak, there is a large continuum (E_m > 50 MeV) cross section extending out to the deepest missing energy measured, amounting to almost 50% of the measured cross section. The ratio of data to DWIA calculation is 0.4 for both the p- and s-shells. At w=330 MeV, well below the maximum of the quasielastic peak, the continuum cross section is much smaller and the ratio of data to DWIA calculation is 0.85 for the p-shell and 1.0 for the s-shell. We infer that one or more mechanisms that increase with ω\omega transform some of the single-nucleon-knockout into multinucleon knockout, decreasing the valence knockout cross section and increasing the continuum cross section.Comment: 14 pages, 7 figures, Revtex (multicol, prc and aps styles), to appear in Phys Rev
    • 

    corecore