38 research outputs found

    Journal of Physics: Conference Series / Regional lung deposition of aged and diluted sidestream tobacco smoke

    Get PDF
    Since aged and diluted smoke particles are in general smaller and more stable than mainstream tobacco smoke, it should be possible to model their deposition on the basis of their measured particle diameters. However in practice, measured deposition values are consistently greater than those predicted by deposition models. Thus the primary objective of this study was to compare theoretical predictions obtained by the Monte Carlo code IDEAL with two human deposition studies to attempt to reconcile these differences. In the first study, male and female volunteers inhaled aged and diluted sidestream tobacco smoke at two steady-state concentrations under normal tidal breathing conditions. In the second study, male volunteers inhaled aged and diluted sidestream smoke labelled with 212Pb to fixed inhalation patterns. Median particle diameters in the two studies were 125 nm (CMD) and 210 nm (AMD), respectively. Experimental data on total deposition were consistently higher than the corresponding theoretical predictions, exhibiting significant inter-subject variations. However, measured and calculated regional deposition data are quite similar to each other, except for the extra-thoracic region. This discrepancy suggests that either the initial particle diameter decreases upon inspiration and/or additional deposition mechanisms are operating in the case of tobacco smoke particles.(VLID)220918

    Assessment of an in vitro whole cigarette smoke exposure system: The Borgwaldt RM20S 8-syringe smoking machine

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>There have been many recent developments of <it>in vitro </it>cigarette smoke systems closely replicating <it>in vivo </it>exposures. The Borgwaldt RM20S smoking machine (RM20S) enables the serial dilution and delivery of cigarette smoke to exposure chambers for <it>in vitro </it>analyses. In this study we have demonstrated reliability and robustness testing of the RM20S in delivering smoke to <it>in vitro </it>cultures using an in-house designed whole smoke exposure chamber.</p> <p>Results</p> <p>The syringe precision and accuracy of smoke dose generated by the RM20S was assessed using a methane gas standard and resulted in a repeatability error of ≤9%. Differential electrical mobility particle spectrometry (DMS) measured smoke particles generated from reference 3R4F cigarettes at points along the RM20S. 53% ± 5.9% of particles by mass reached the chamber, the remainder deposited in the syringe or connecting tubing and ~16% deposited in the chamber. Spectrofluorometric quantification of particle deposition within chambers indicated a positive correlation between smoke concentration and particle deposition. <it>In vitro </it>air-liquid interface (ALI) cultures (H292 lung epithelial cells), exposed to whole smoke (1:60 dilution (smoke:air, equivalent to ~5 μg/cm<sup>2</sup>)) demonstrated uniform smoke delivery within the chamber.</p> <p>Conclusions</p> <p>These results suggest this smoke exposure system is a reliable and repeatable method of generating and exposing ALI <it>in vitro </it>cultures to cigarette smoke. This system will enable the evaluation of future tobacco products and individual components of cigarette smoke and may be used as an alternative <it>in vitro </it>tool for evaluating other aerosols and gaseous mixtures such as air pollutants, inhaled pharmaceuticals and cosmetics.</p

    Interaction between SH0 guided waves and tilted surface-breaking cracks in plates

    Get PDF
    The interaction between SH0 guided waves and simple defects is well understood and documented, and the SH0 and related torsional guided waves are commonly used in inspection. However, tilted and branching cracks, for which vertical notches are a poor approximation, are found in some environments, particularly when pipes are buried in alkaline soils. This paper studies the interaction between SH0 guided waves and tilted, surface-breaking cracks, investigating the effect of the tilt and depth of the defect. The incident wave interacts with the tilted crack to generate a transmitted wave, a reflected wave and a wave trapped below the crack. It is shown that the direction of the tilt of the crack relative to the incident wave direction does not affect the scattering behaviour. Additionally, the axial extent of the crack plays a major role in the reflectivity of the crack, leading to transmission nulls in some configurations. These transmission nulls appear for all crack depths, the frequency range over which the transmission is significantly reduced increasing with crack depth. This behaviour is shown to be analogous to the acoustic energy flow in a duct when a Helmholtz resonator is introduced. The null is not seen above the SH1 cut-off as the propagating signals are no longer mono-modal. The existence of a transmission null and corresponding reflection maximum is promising for the detection of small defects and measurement of the frequency at which the null occurs will assist with defect characterisation. Experimental validations of the key results are presented

    Influence of filter ventilation on the chemical composition of cigarette mainstream smoke.

    No full text
    Total yields of cigarette smoke constituents are greatly influenced by smoking behaviour, the tobacco blend as well as a variety of cigarette design parameters. Thereby, filter ventilation, i.e. diluting the smoke by providing a zone of microscopic holes around the circumference of the filter is one method to reduce the yield of &#39;tar&#39; and other smoke compounds. However, little is known how these design variations influence the combustion conditions, and therefore, the overall chemical pattern of the smoke. In this paper single photon ionization-time-of-flight mass spectrometry (SPI-TOFMS) is used to characterize and compare cigarettes on a puff-by-puff basis, which differ only in filter ventilation magnitude. The research cigarettes investigated were made from Virginia tobacco and featured filter ventilations of 0% (no ventilation), 35%, and 70%. The cigarettes were smoked under two different puffing regimes, one using the puffing parameters of the conventional International Organization for Standardization (ISO) smoking regime and a more intense smoking condition. Results show that every variation entails a change of the chemical pattern, whereby, in general, cigarettes with 0% filter ventilation as well as the intense smoking regime lead to a more complete combustion compared to the ISO smoking conditions and the high ventilated cigarettes. Changes in the overall patterns can also be observed during the smoking for individual puffs. Some substances dominate the first puff, some species are more pronounced in the middle puffs, whereas others are preferably formed in the last puffs. This demonstrates the high complexity of the occurring processes. Results might help to understand the formation and decomposition reactions taking place when a cigarette is smoked and offer scope for targeted reduction strategies for specific toxicants or groups of toxicants in the smoke

    Simultaneous on-line size and chemical analysis of gas phase and particulate phase of cigarette mainstream smoke.

    No full text
    This paper describes the combined set-up of on-line chemical analysis of gas phase by single-photon ionisation/resonance enhanced multiphoton ionisation-time-of-flight mass spectrometry (SPI/REMPI-TOFMS) and on-line particle size analysis by differential electrical mobility particle spectrometry (DMS 500) for the investigation of fresh cigarette mainstream smoke. SPI is well suited for the investigation of a great variety of organic species, whereas REMPI is highly sensitive for aromatic compounds. Gas phase measurements of filtered and unfiltered smoke are possible with the SPI/REMPI-TOFMS in order to determine the influence of the presence of particles on the chemical composition of the gas phase. Initial results are shown for the characterisation and comparison of three pure Virginia tobacco research cigarettes having filter ventilations of 0%, i.e. no filter ventilation, 35% and 70% ventilation. The three cigarette types are smoked under two different smoking regimes, a standard regime using puff parameters equivalent to the conventional International Standard Organisation regime and a more intense smoking regime. For the gas phase, qualitative puff-by-puff resolved yields of three selected compounds (acetaldehyde, phenol and styrene) are shown and compared. For particulate matter, particle number, count median diameter and total surface area are illustrated on a puff-by-puff basis. Yields of the chemicals analysed, puff number and surface area are in good agreement with the intensity of the smoking regime and the dilution of smoke by filter ventilation. However, gaseous compounds are influenced differently, depending whether an absolute particle filter is present or not, i.e. they can be totally removed (phenol), partially removed (styrene) or not affected (acetaldehyde). For particle analysis, the count median diameter decreases from puff to puff and is strongly dependent on the smoking regime and ventilation rate. Thereby, 0% ventilated cigarettes smoked under the intense regime result in the smallest count median diameters of ca. 180 nm, whereas 70% ventilated cigarettes smoked with a standard regime lead to the largest values of up to 280 nm. As particle diameter increases, particle number decreases as a consequence of increasing time for particle coagulation
    corecore