91 research outputs found

    On the theory of Gordan-Noether on homogeneous forms with zero Hessian (Improved version)

    Full text link
    We give a detailed proof for Gordan-Noether's results in "Ueber die algebraischen Formen, deren Hesse'sche Determinante identisch verschwindet" published in 1876 in Mathematische Annahlen. C. Lossen has written a paper in a similar direction as the present paper, but did not provide a proof for every result. In our paper, every result is proved. Furthermore, our paper is independent of Lossen's paper and includes a considerable number of new observations. An earlier version of this paper has been printed in Proceedings of the School of Science of Tokai University, Vol.49, Mar. 2014. In this version, a serious error has been corrected and some new results have been added

    Equianalytic and equisingular families of curves on surfaces

    Get PDF
    We consider flat families of reduced curves on a smooth surface S such that each member C has the same number of singularities of fixed singularity types and the corresponding (locally closed) subscheme H of the Hilbert scheme of S. We are mainly concerned with analytic resp. topological singularity types and give a sufficient condition for the smoothness of H (at C). Our results for S=P^2 seem to be quite sharp for families of cuves of small degree d.Comment: LaTeX v 2.0

    The Performance of Private Equity Funds: Does Diversification Matter?

    Get PDF
    This paper is the first systematic analysis of the impact of diversification on the performance of private equity funds. A unique data set allows the exact evaluation of diversification across the dimensions financing stages, industries, and countries. Very different levels of diversification can be observed across sample funds. While some funds are highly specialized others are highly diversified. The empirical results show that the rate of return of private equity funds declines with diversification across financing stages, but increases with diversification across industries. Accordingly, the fraction of portfolio companies which have a negative return or return nothing at all, increase with diversification across financing stages. Diversification across countries has no systematic effect on the performance of private equity funds

    Process Development for a High-throughput Fine Line Metallization Approach Based on Dispensing Technology

    Get PDF
    AbstractIn order to enhance prosperous dispensing technology towards an industrial application, besides a continuous process development, especially throughput rate has to be increased. In this study, paste rheology of two different dispensing pastes was transferred to CFD-simulation (CFD: Computational Fluid Dynamics) to investigate different nozzle geometries and print head designs. In the following, a single nozzle dispensing setup was used to verify simulative values by comparing them with those obtained from experimental investigations. Consequently, the single nozzle process was scaled to a parallel application, where a homogeneous pressure and flow distribution within the print head turned out to be crucial to achieve a homogeneous mass flow at all nozzles. In various iteration steps, the influence of fabrication tolerances especially concerning the nozzle geometry was isolated and print head designs were optimized based on CFD towards maximum process stability. Based on these results, a novel 10 nozzle fine line dispensing unit was designed and fabricated. Finally, successful cell production with resulting finger widths of less than 35μm could be demonstrated using the novel prototype

    Neuromuscular Blockade with Rocuronium Bromide Increases the Tolerance of Acute Normovolemic Anemia in Anesthetized Pigs

    Get PDF
    Background: The patient's individual anemia tolerance is pivotal when blood transfusions become necessary, but are not feasible for some reason. To date, the effects of neuromuscular blockade (NMB) on anemia tolerance have not been investigated. Methods: 14 anesthetized and mechanically ventilated pigs were randomly assigned to the Roc group (3.78 mg/kg rocuronium bromide followed by continuous infusion of 1 mg/kg/min, n = 7) or to the Sal group (administration of the corresponding volume of normal saline, n = 7). Subsequently, acute normovolemic anemia was induced by simultaneous exchange of whole blood for a 6% hydroxyethyl starch solution (130/0.4) until a sudden decrease of total body O-2 consumption (VO2) indicated a critical limitation of O-2 transport capacity. The Hb concentration quantified at this time point (Hb(crit)) was the primary end-point of the protocol. Secondary endpoints were parameters of hemodynamics, O-2 transport and tissue oxygenation. Results: Hb(crit) was significantly lower in the Roc group (2.4 +/- 0.5 vs. 3.2 +/- 0.7 g/dl) reflecting increased anemia tolerance. NMB with rocuronium bromide reduced skeletal muscular VO2 and total body O-2 extraction rate. As the cardiac index increased simultaneously, total body VO2 only decreased marginally in the Roc group (change of VO2 relative to baseline -1.7 +/- 0.8 vs. 3.2 +/- 1.9% in the Sal group, p < 0.05). Conclusion: Deep NMB with rocuronium bromide increases the tolerance of acute normovolemic anemia. The underlying mechanism most likely involves a reduction of skeletal muscular VO2. During acellular treatment of an acute blood loss, NMB might play an adjuvant role in situations where profound stages of normovolemic anemia have to be tolerated (e.g. bridging an unexpected blood loss until blood products become available for transfusion). Copyright (C) 2011 S. Karger AG, Base

    Optimization of the filament arrangement at constant radiant heat in HW-CVD for the preparation of compact µc-Si:H at high deposition rates

    No full text
    To obtain high deposition rates for microcrystalline silicon (muc-Si:H) with the Hot-Wire-CVD process under the constraint of a low substrate temperature of 250 degreesC, various combinations of hot wire arrangements and filament temperatures have been investigated. Raman and infrared spectroscopy and measurements of the dark and photo conductivity are used to evaluate the quality of the material. It is found that lowering the filament-substrate distance at low filament temperature results in a better material quality than higher filament temperatures at larger filament distances. High quality muc-Si:H was deposited at approximately 4 Angstrom s(-1) with filament temperatures of 1700-1750 degreesC and filament-substrate distances of 50-54 mm. (C) 2003 Elsevier B.V. All rights reserved

    Über Phrenicusexhairese bei einem Fall von kavernöser Phthise des rechten Oberlappens

    No full text
    • …
    corecore