95,525 research outputs found

    Chromium ion plating studies for enhancement of bearing lifetime

    Get PDF
    Six 440-C hardened stainless steel roller bearing test rods were ion plated with various chromium films of thicknesses from .2 microns to 7 microns. The thinner (approximately .2 microns) coating sample had 3 times the fatigue life of the unplated (standard) specimens. Contrastingly, the samples having thicker coatings (several microns) had short fatigue lives (about 3% of the unplated standard)

    C.V.D. annual report: November 1965 research project RU27-1 :an analogue method for the determination of potential distributions in semiconductor systems

    Get PDF
    A general method for the solution of the nonlinear Shockley-Poisson differential equation which governs the potential distribution in non-degenerate semiconductor systems is described which can be applied to the evaluation of depletion layer widths, carrier densities and capacitance bias relationships of p-n junction structures. The method is based upon the use of a particular type of resistance network analogue and results obtained for several one and two dimensional configurations are discussed

    Pointing of the 16 foot antenna

    Get PDF
    Comprehensive pointing theory for 16 ft antenna including servo encoder reading

    Space environmental effects: Construction and utilization of a system to measure low thermal strain in one meter graphite epoxy tubes

    Get PDF
    A system for measuring the expansion of low coefficient of thermal expansion (CTE) materials was constructed around a H.P. 5526-A laser measuring system. The vacuum CTE measurements in the -150 F to +120 F range were made over a 6 month period on a graphite epoxy tube yielding CTE values of 2.5 to one fifty-millionth/F above ambient and 2 + or - one ten-millionth F below ambient temperature. To assure that the below ambient, approximately 10 microns high open loop nature of the delta L/L vs. T curves was not apparatus related, similar size quartz tubes (A and B) were checked and found to have only a 2 micron (negligable for quartz) open loop component. These two quartz tubes, A and B, had ambient CTE values 20% and 45% respectively higher than the average handbook value. The overnight microcreep diminished an order of magnitude during the first several cycles after the system had been reopened

    Blood pressure and indices of glomerular filtration area in hypertensive and normotensive Prague rats

    Get PDF
    The involvement of the kidney in the pathogenesis of hypertension has long been recognised, although the specific renal mechanisms underlying this phenomenon are still unknown. A current hypothesis attributes hyper tension to a reduction in glomerular filtration area by glomerular loss, The present study analyses the relationship between glomerular number and volume and conscious systolic blood pressure (SBP) in 4- to 53-week-old hypertensive (PHR) and normotensive (PNR) rats of the Prague strain. Adult PHRs had higher SEP, were larger and had larger kidneys than PNRs, but 20% fewer glomeruli, A significant negative correlation between SEP and glomerular number was found in PHR males, but not in PHR females or PNRs. There was no correlation at all between glomerular volume and SEP and, in young animals, both SEP and glomerular number were higher in PHRs than in PNRs. In addition, in adult PHRs, glomerular volume and SEP were higher in males than in females. In summary, a generally valid, causal relation-ship linking raised blood pressure to decreased glomerular number or volume could not be demonstrated in the Prague rat model of genetically determined hypertension. The nature of the renal mechanism(s) determining the hypertension in this model remains unknown. Copyright (C) 2000 S. Karger AG, Basel

    Millimeter wavelength spectroscopy and continuum studies of the planets

    Get PDF
    Careful observations were made at 86.1 GHz to derive the absolute brightness temperatures of the Sun (7914 + or - 192 K), Venus (357.5 + or - 13.1 K), Jupiter (179.4 + or - 4.7K), and Saturn (153.4 + or - 4.8 K) with a standard error of about 3%. This is a significant improvement in accuracy over previous results. A stable transmitter and novel superheterodyne receiver were constructed and used to determine the effective collecting area of the MWO 4.9 m antenna relative to a previously calibrated standard gain horn. The thermal scale was set by calibrating the radiometer with carefully constructed and tested hot and cold loads. The brightness temperatures may be used to establish an absolute calibration scale and to determine the antenna aperture and beam efficiencies of other radio telescopes at 3.5 mm wavelength

    Rolling contact fatigue life of chromium ion plated 440C bearing steel

    Get PDF
    Rolling contact fatigue (RCF) test specimens of heat treated 440C bearing steel were chromium ion plated in thicknesses from 0.1 to 8.0 micron and tested in RCF tester using 700 ksi maximum Hertzian stress. Heavy coatings, greater than about 5 micron in thickness, peeled off or spalled readily, whereas thin coatings, less than 3 micron thick, were tenacious and did not come off. Furthermore, significant improvement in RCF life was obtained with thin chromium ion plated test specimens. The average increase in B10 life was 75% compared with unplated 440C. These preliminary results indicate that ion plating is a promising way to improve bearing life
    • …
    corecore