47,007 research outputs found

    Thirty-Three Stata Tips

    Get PDF
    Since 2003, the Stata Journal has published Stata Tips on special issues in data analysis with Stata. Now Thirty-three Stata Tips compiles these useful guides into a compact tome for ease of reference. In keeping with the Stata spirit, Tips are from Stata users and StataCorp employees alike and will serve as guideposts for both new and experienced users.data management, statistics, graphics, Stata

    Broadband power amplifier tube: Klystron tube 5K70SK-WBT and step tuner VA-1470S

    Get PDF
    The design concept, the fabrication, and the acceptance testing of a wide band Klystron tube and remotely controlled step tuner for channel selection are discussed. The equipment was developed for the modification of an existing 20 KW Power Amplifier System which was provided to the contractor as GFE. The replacement Klystron covers a total frequency range of 2025 to 2120 MHz and is tuneable to six (6) each channel with a band width of 22 MHz or greater per channel. A 5 MHz overlap is provided between channels. Channels are selected at the control panel located in the front of the Klystron magnet or from one of three remote control stations connected in parallel with the step tuner. Included in this final report are the results of acceptance tests conducted at the vendor's plant and of the integrated system tests

    Apollo experience report: Guidance and control systems - Digital autopilot design development

    Get PDF
    The development of the Apollo digital autopilots (the primary attitude control systems that were used for all phases of the lunar landing mission) is summarized. This report includes design requirements, design constraints, and design philosophy. The development-process functions and the essential information flow paths are identified. Specific problem areas that existed during the development are included. A discussion is also presented on the benefits inherent in mechanizing attitude-controller logic and dynamic compensation in a digital computer

    Finite element optimizations for efficient non-linear electrical tomography reconstruction

    No full text
    Electrical Tomography can produce accurate results only if the underlying 2D or 3D volume discretization is chosen suitably for the applied numerical algorithm. We give general indications where and how to optimize a finite element discretization of a volume under investigation to enable efficient computation of potential distributions and the reconstruction of materials. For this, we present an error estimator and material-gradient indicator as a driver for adaptive mesh refinement and show how finite element mesh properties affect the efficiency and accuracy of the solutions

    Study of the order of the phase transition in pure U(1) gauge theory with Villain action

    Get PDF
    We address the question of the order of the deconfinement phase transition of four dimensional U(1) lattice gauge theory. Simulations of the Z-gauge theory dual to the Villain action on toroidal lattices up to lattice sizes of 28^4 give results consistent with both, a vanishing and a nonvanishing discontinuity in the thermodynamic limit. A decision on the order of the phase transition requires still larger lattice sizes.Comment: LATTICE98(gauge), 3 pages, 2 figure

    High fidelity imaging and high performance computing in nonlinear EIT

    No full text
    We show that nonlinear EIT provides images with well defined characteristics when smoothness of the image is used as a constraint in the reconstruction process. We use the gradient of the logarithm of resistivity as an effective measure of image smoothness, which has the advantage that resistivity and conductivity are treated with equal weight. We suggest that a measure of the fidelity of the image to the object requires the explicit definition and application of such a constraint. The algorithm is applied to the simulation of intra-ventricular haemorrhaging (IVH) in a simple head model. The results indicate that a 5% increase in the blood content of the ventricles would be easily detectable with the noise performance of contemporary instrumentation. The possible implementation of the algorithm in real time via high performance computing is discussed

    Antenna servo control system characterization: Rate loop analysis for 34-m antenna at DSS 15

    Get PDF
    The elevation and azimuth servo rate loops at the 34-m High Efficiency Deep Space Station 15 (DSS 15) are described. Time and frequency response performance criteria were measured. The results are compared to theoretically deduced performance criteria. Unexpected anomalies in the frequency response are observed and identified

    Small Energy Scale for Mixed-Valent Uranium Materials

    Full text link
    We investigate a two-channel Anderson impurity model with a 5f15f^1 magnetic and a 5f25f^2 quadrupolar ground doublet, and a 5f25f^2 excited triplet. Using the numerical renormalization group method, we find a crossover to a non-Fermi liquid state below a temperature T∗T^* varying as the 5f25f^2 triplet-doublet splitting to the 7/2 power. To within numerical accuracy, the non-linear magnetic susceptibility and the 5f15f^1 contribution to the linear susceptibility are given by universal one-parameter scaling functions. These results may explain UBe13_{13} as mixed valent with a small crossover scale T∗T^*.Comment: 4 pages, 3 figures, REVTeX, to appear in Phys. Rev. Let

    Research on solar pumped liquid lasers

    Get PDF
    A solar pumped liquid laser that can be scaled up to high power (10Mw CW) for space applications was developed. Liquid lasers have the inherent advantage over gases in that they provide much higher lasant densities and thus high power densities. Liquids also have inherent advantages over solids in that they have much higher damage thresholds and are much cheaper to produce for large scale applications. Among the liquid laser media that are potential candidates for solar pumping, the POC13:Nd(3+):ZrC14 liquid was chosen for its high intrinsic efficiency as well as its relatively good stability against decomposition due to protic contamination. The development and testing of the laser liquid and the development of a large solar concentrator to pump the laser was emphasized. The procedure to manufacture the laser liquid must include diagnostic tests of the solvent purity (from protic contamination) at various stages in the production process
    • …
    corecore