23 research outputs found

    Temporal relationship between instantaneous pressure gradients and peak‐to‐peak systolic ejection gradient in congenital aortic stenosis

    Full text link
    ObjectiveWe sought to identify a time during cardiac ejection when the instantaneous pressure gradient (IPG) correlated best, and near unity, with peak‐to‐peak systolic ejection gradient (PPSG) in patients with congenital aortic stenosis. Noninvasive echocardiographic measurement of IPG has limited correlation with cardiac catheterization measured PPSG across the spectrum of disease severity of congenital aortic stenosis. A major contributor is the observation that these measures are inherently different with a variable relationship dependent on the degree of stenosis.DesignHemodynamic data from cardiac catheterizations utilizing simultaneous pressure measurements from the left ventricle (LV) and ascending aorta (AAo) in patients with congenital valvar aortic stenosis was retrospectively reviewed over the past 5 years. The cardiac cycle was standardized for all patients using the percentage of total LV ejection time (ET). Instantaneous gradient at 5% intervals of ET were compared to PPSG using linear regression and Bland‐Altman analysis.ResultsA total of 22 patients underwent catheterization at a median age of 13.7 years (interquartile range [IQR] 10.3‐18.0) and median weight of 51.1 kg (IQR 34.2‐71.6). The PPSG was 46.5 ± 12.6 mm Hg (mean ± SD) and correlated suboptimally with the maximum and mean IPG. The midsystolic IPG (occurring at 50% of ET) had the strongest correlation with the PPSG (PPSG = 0.97(IPG50%)–1.12, R2 = 0.88), while the IPG at 55% of ET was closest to unity (PPSG = 0.997(IPG55%)–1.17, R2 = 0.87).ConclusionsThe commonly measured maximum and mean IPG are suboptimal estimates of the PPSG in congenital aortic stenosis. Using catheter‐based data, IPG at 50%–55% of ejection correlates well with PPSG. This may allow for a more accurate estimation of PPSG via noninvasive assessment of IPG.Peer Reviewedhttps://deepblue.lib.umich.edu/bitstream/2027.42/140042/1/chd12514.pdfhttps://deepblue.lib.umich.edu/bitstream/2027.42/140042/2/chd12514_am.pd

    Comprehensive comparative outcomes in children with congenital heart disease: The rationale for the Congenital Catheterization Research Collaborative

    Full text link
    Clinical research in the treatment of patients with congenital heart disease (CHD) is limited by the wide variety of CHD manifestations and therapeutic options as well as the generally low incidence of CHD. The availability of comprehensive, contemporary outcomes studies is therefore limited. This inadequacy may result in a lack of data‐driven medical decision making. In 2013, clinician scientists at two centers began a research collaboration, the Congenital Catheterization Research Collaborative (CCRC). Over time, the CCRC has grown to include nine cardiac centers from across the United States, with a common data coordinating center. The CCRC seeks to generate high‐quality, contemporary, statistically robust, and generalizable outcomes research which can help address important clinical questions in the treatment of CHD. To date, the CCRC has reported on multicenter outcomes in: neonates with congenital aortic stenosis, infants undergoing right ventricular decompression for pulmonary atresia and intact ventricular septum, and infants with ductal‐dependent pulmonary blood flow. The CCRC has been successful at leveraging large multicenter cohorts of patients in a contemporary period to perform comparative studies. In the future, the CCRC plans to continue to perform hypothesis‐driven retrospective and prospective observational studies of CHD populations where controversy exists or where novel interventions or therapies have emerged. Quality improvement efforts including lesion‐specific registry development may be an additional potential future target.Peer Reviewedhttps://deepblue.lib.umich.edu/bitstream/2027.42/149494/1/chd12737.pdfhttps://deepblue.lib.umich.edu/bitstream/2027.42/149494/2/chd12737_am.pd

    Junctional ectopic tachycardia after infant heart surgery: Incidence and outcomes

    No full text
    Junctional ectopic tachycardia (JET) is an arrhythmia observed almost exclusively after open heart surgery in children. Current literature on JET has not focused on patients at the highest risk of both developing and being negatively impacted by JET. The purpose of this study was to determine the overall incidence of JET in an infant patient cohort undergoing open cardiac surgery, to identify patient- and procedure-related factors associated with developing JET, and to assess the clinical impact of JET on patient outcomes. We performed a nested case-control study from the complete cohort of patients at our institution younger than 1 year of age who underwent open heart surgery between 2005 and 2010. JET patients were compared with an age matched control group undergoing open heart surgery without JET regarding potential risk factors and outcomes. The overall incidence of JET in infants after open cardiac surgery was 14.3 %. From multivariate analyses, complete repair of tetralogy of Fallot [adjusted odds ratio (AOR) 2.0, 95 % CI 1.12-3.57] and longer aortic cross clamp times (AOR 1.02, 95 % CI 1.01-1.03) increased the risk of developing JET. Patients with JET had longer length of intubation, intensive care unit stays, and total length of hospitalization, and were more likely to require extracorporeal membrane oxygenation support (13 vs. 4.3 %). JET is a common postoperative arrhythmia in infants after open heart operations. Both anatomic substrate and surgical procedure contribute to the overall risk of developing JET. Developing JET is associated with worse clinical outcomes. © 2012 Springer Science+Business Media, LLC

    Data quality methods through remote source data verification auditing: Results from the Congenital Cardiac Research Collaborative

    No full text
    BACKGROUND: Multicentre research databases can provide insights into healthcare processes to improve outcomes and make practice recommendations for novel approaches. Effective audits can establish a framework for reporting research efforts, ensuring accurate reporting, and spearheading quality improvement. Although a variety of data auditing models and standards exist, barriers to effective auditing including costs, regulatory requirements, travel, and design complexity must be considered. MATERIALS AND METHODS: The Congenital Cardiac Research Collaborative conducted a virtual data training initiative and remote source data verification audit on a retrospective multicentre dataset. CCRC investigators across nine institutions were trained to extract and enter data into a robust dataset on patients with tetralogy of Fallot who required neonatal intervention. Centres provided de-identified source files for a randomised 10% patient sample audit. Key auditing variables, discrepancy types, and severity levels were analysed across two study groups, primary repair and staged repair. RESULTS: Of the total 572 study patients, data from 58 patients (31 staged repairs and 27 primary repairs) were source data verified. Amongst the 1790 variables audited, 45 discrepancies were discovered, resulting in an overall accuracy rate of 97.5%. High accuracy rates were consistent across all CCRC institutions ranging from 94.6% to 99.4% and were reported for both minor (1.5%) and major discrepancies type classifications (1.1%). CONCLUSION: Findings indicate that implementing a virtual multicentre training initiative and remote source data verification audit can identify data quality concerns and produce a reliable, high-quality dataset. Remote auditing capacity is especially important during the current COVID-19 pandemic

    Gastric ciliated metaplasia. A study of 3406 gastrectomy specimens from dwellers of the Atlantic and the Pacific basins

    No full text
    Background: Ciliated cells in gastrectomies from patients dwelling in the Pacific and Atlantic basins have been reported previously. Aim: To compare all the results in an attempt to explain the findings. Methods: Sections from 3406 gastrectomies were reviewed: 1966 and 1440 from the Atlantic and Pacific basins, respectively. Ciliated cells and intestinal metaplasia (IM) were recorded; IM was classified into focal or extensive IM. The total number of sections/gastrectomy was noted. Results: In the Atlantic basin, 5% of specimens had ciliated metaplasia (CM); it was more frequent in intestinal carcinoma (IC; 9%) than diffuse carcinoma (DC; 3%) or miscellaneous gastric diseases (MGD; 3%). In the Pacific basin, the frequency of specimens with CM was 29%: it was more frequent in IC (43%) than in DC (16%) or MGD (10%). The difference between the frequency of CM in specimens with IC or with DC/MGD in the Atlantic and the Pacific basins was significant (p â©œ 0.05). The presence of CM was influenced by age and the extent of IM in both basins, but not by sex or the number of sections investigated. Conclusions: CM—apparently an independent microscopic marker—was significantly higher in the Pacific than in the Atlantic basin. Environmental carcinogens involved in the evolution of IM and IC seem to be implicated in gastric ciliogenesis. Carcinogens that differ in nature and/or in strength in both basins might activate the latent natural genes encoding ciliated processes in gastric cells in patients subsequently developing gastric carcinoma, more notably of intestinal type

    Comparison of the investigational device exemption and post-approval trials of the Melody transcatheter pulmonary valve

    No full text
    OBJECTIVE: We compared 5-year outcomes of transcatheter pulmonary valve (TPV) replacement with the Melody TPV in the post-approval study (PAS) and the investigational device exemption (IDE) trial. BACKGROUND: As a condition of approval of the Melody TPV after the IDE trial, the Food and Drug Administration required that a PAS be conducted to evaluate outcomes of TPV replacement in a real-world environment. The 5-year outcomes of the PAS have not been published, and the IDE and PAS trials have not been compared. METHODS: The cohorts comprised all patients catheterized and implanted at 5 IDE sites and 10 PAS sites. Differences in trial protocols were detailed. Time-related outcomes and valve-related adverse events were compared between the two trials with Kaplan-Meier curves and log-rank testing. RESULTS: 167 patients (median age, 19 years) were catheterized and 150 underwent TPV replacement in the IDE trial; 121 were catheterized (median age, 17 years) and 100 implanted in the PAS. Freedom from hemodynamic dysfunction (p = .61) or any reintervention (p = .74) over time did not differ between trials. Freedom from stent fracture (p = .003) and transcatheter reintervention (p = .010) were longer in PAS, whereas freedom from explant (p = .020) and TPV endocarditis (p = .007) were shorter. Clinically important adverse events (AEs) were reported in 14% of PAS and 7.2% of IDE patients (p = .056); the incidence of any particular event was low in both. CONCLUSIONS: Hemodynamic and time-related outcomes in the PAS and IDE trials were generally similar, confirming the effectiveness of the Melody TPV with real-world providers. There were few significant complications and limited power to identify important differences in AEs. The lack of major differences in outcomes between the two studies questions the usefulness of mandated costly post-approval studies as part of the regulatory process for Class III medical devices

    Comparison of the investigational device exemption and post‐approval trials of the Melody transcatheter pulmonary valve

    Full text link
    ObjectiveWe compared 5‐year outcomes of transcatheter pulmonary valve (TPV) replacement with the Melody TPV in the post‐approval study (PAS) and the investigational device exemption (IDE) trial.BackgroundAs a condition of approval of the Melody TPV after the IDE trial, the Food and Drug Administration required that a PAS be conducted to evaluate outcomes of TPV replacement in a “real‐world” environment. The 5‐year outcomes of the PAS have not been published, and the IDE and PAS trials have not been compared.MethodsThe cohorts comprised all patients catheterized and implanted at 5 IDE sites and 10 PAS sites. Differences in trial protocols were detailed. Time‐related outcomes and valve‐related adverse events were compared between the two trials with Kaplan–Meier curves and log‐rank testing.Results167 patients (median age, 19 years) were catheterized and 150 underwent TPV replacement in the IDE trial; 121 were catheterized (median age, 17 years) and 100 implanted in the PAS. Freedom from hemodynamic dysfunction (p = .61) or any reintervention (p = .74) over time did not differ between trials. Freedom from stent fracture (p = .003) and transcatheter reintervention (p = .010) were longer in PAS, whereas freedom from explant (p = .020) and TPV endocarditis (p = .007) were shorter. Clinically important adverse events (AEs) were reported in 14% of PAS and 7.2% of IDE patients (p = .056); the incidence of any particular event was low in both.ConclusionsHemodynamic and time‐related outcomes in the PAS and IDE trials were generally similar, confirming the effectiveness of the Melody TPV with real‐world providers. There were few significant complications and limited power to identify important differences in AEs. The lack of major differences in outcomes between the two studies questions the usefulness of mandated costly post‐approval studies as part of the regulatory process for Class III medical devices.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/169335/1/ccd29657_am.pdfhttp://deepblue.lib.umich.edu/bitstream/2027.42/169335/2/ccd29657.pd
    corecore