14,462 research outputs found
Heat flow calorimeter
Heat flow calorimeter devices are used to measure heat liberated from or absorbed by an object. This device is capable of measuring the thermal output of sealed nickel-cadmium batteries or cells during charge-discharge cycles. An elongated metal heat conducting rod is coupled between the calorimeter vessel and a heat sink, thus providing the only heat exchange path from the calorimeter vessel itself
Annoyance resulting from intrusion of aircraft sounds upon various activities
An experiment was conducted in which subjects were engaged in TV viewing, telephone listening, or reverie (no activity) for a 1/2-hour session. During the session, they were exposed to a series of recorded aircraft sounds at the rate of one flight every 2 minutes. Within each session, four levels of flyover noise, separated by dB increments, were presented several times in a Latin Square balanced sequence. The peak level of the noisiest flyover in any session was fixed at 95, 90, 85, 75, or 70 dBA. At the end of the test session, subjects recorded their responses to the aircraft sounds, using a bipolar scale which covered the range from very pleasant to extremely annoying. Responses to aircraft noises were found to be significantly affected by the particular activity in which the subjects were engaged. Not all subjects found the aircraft sounds to be annoying
Effects of three activities on annoyance responses to recorded flyovers
Human subjects participated in an experiment in which they were engaged in TV viewing, telephone listening, or reverie (no activity) for a 1/2-hour session. During the session, they were exposed to a series of recorded aircraft sounds at the rate of one flight every 2 minutes. At each session, four levels of flyover noise, separated by 5 db increments were presented several times in a Latin Square balanced sequence. The peak levels of the noisiest flyover in any session was fixed at 95, 90, 85, 75, or 70 db. At the end of the test session, subjects recorded their responses to the aircraft sounds, using a bipolar scale which covered the range from very pleasant to extremely annoying. Responses to aircraft noises are found to be significantly affected by the particular activity in which the subjects are engaged
Policy for the implementation of ecologically sustainable development fisheries and aquaculture within Western Australia
The purpose of this ESD policy is to outline a way forward by showing in a practical manner: • how the ESD principles will be interpreted and applied within the fisheries context generally and within the Department of Fisheries specifically, • the conceptual framework that will be used to assess performance against ESD principles, • the methods for reporting on and auditing this performance, and • how these principles and the framework relate to other relevant state, national and international treaties and instruments
Weld procedure produces quality welds for thick sections of Hastelloy-X
Welding program produces premium quality, multipass welds in heavy tube sections of Hastelloy-X. It develops semiautomatic tungsten/inert gas procedures, weld wire procurement specifications material weld properties, welder-operator training, and nondestructive testing inspection techniques and procedures
Feasibility of a chemical poison loop system
Chemical poison loop system for reactivity control of tungsten water moderated rocket reacto
A polynomial training algorithm for calculating perceptrons of optimal stability
Recomi (REpeated COrrelation Matrix Inversion) is a polynomially fast
algorithm for searching optimally stable solutions of the perceptron learning
problem. For random unbiased and biased patterns it is shown that the algorithm
is able to find optimal solutions, if any exist, in at worst O(N^4) floating
point operations. Even beyond the critical storage capacity alpha_c the
algorithm is able to find locally stable solutions (with negative stability) at
the same speed. There are no divergent time scales in the learning process. A
full proof of convergence cannot yet be given, only major constituents of a
proof are shown.Comment: 11 pages, Latex, 4 EPS figure
A new efficient method for determining weighted power spectra: detection of low-frequency solar p-modes by analysis of BiSON data
We present a new and highly efficient algorithm for computing a power
spectrum made from evenly spaced data which combines the noise-reducing
advantages of the weighted fit with the computational advantages of the Fast
Fourier Transform (FFT). We apply this method to a 10-year data set of the
solar p-mode oscillations obtained by the Birmingham Solar Oscillations Network
(BiSON) and thereby uncover three new low-frequency modes. These are the l=2,
n=5 and n=7 modes and the l=3, n=7 mode. In the case of the l=2, n=5 modes,
this is believed to be the first such identification of this mode in the
literature. The statistical weights needed for the method are derived from a
combination of the real data and a sophisticated simulation of the instrument
performance. Variations in the weights are due mainly to the differences in the
noise characteristics of the various BiSON instruments, the change in those
characteristics over time and the changing line-of-sight velocity between the
stations and the Sun. It should be noted that a weighted data set will have a
more time-dependent signal than an unweighted set and that, consequently, its
frequency spectrum will be more susceptible to aliasing.Comment: 11 pages, 7 Figures, accepted for publication in MNRAS, Figure 6 had
to be reduced in size to upload and so may be difficult to view on screen in
.ps versio
EV space suit gloves (passive)
A pair of pressure and thermal insulating overgloves to be used with an Extravehicular (EV) suit assembly was designed, developed, fabricated, and tested. The design features extensive use of Nomex felt materials in lieu of the multiple layer insulation formerly used with the Apollo thermal glove. The glove theoretically satisfies all of the thermal requirements. The presence of the thermal glove does not degrade pressure glove tactility by more than the acceptable 10% value. On the other hand, the thermal glove generally degrades pressure glove mobility by more than the acceptable 10% value, primarily in the area of the fingers. Life cycling tests were completed with minimal problems. The thermal glove/pressure glove ensemble was also tested for comfort; the test subjects found no problems with the thermal glove although they did report difficulties with pressure points on the pressure glove which were independent of the thermal glove
- …