5,399 research outputs found

    Three-dimensional computed tomography from interferometric measurements within a narrow cone of views

    Get PDF
    A theory to determine the properties of a fluid from measurements of its projections was developed and tested. Viewing cones as small as 10 degrees were evaluated, with the only assumption being that the property was space limited. The results of applying the theory to numerical and actual interferograms of a spherical discontinuity of refractive index are presented. The theory was developed to test the practicality and limits of using three-dimensional computer tomography in internal fluid dynamics

    Advanced Optical Diagnostics for Ice Crystal Cloud Measurements in the NASA Glenn Propulsion Systems Laboratory

    Get PDF
    A light extinction tomography technique has been developed to monitor ice water clouds upstream of a direct connected engine in the Propulsion Systems Laboratory (PSL) at NASA Glenn Research Center (GRC). The system consists of 60 laser diodes with sheet generating optics and 120 detectors mounted around a 36-inch diameter ring. The sources are pulsed sequentially while the detectors acquire line-of-sight extinction data for each laser pulse. Using computed tomography algorithms, the extinction data are analyzed to produce a plot of the relative water content in the measurement plane. To target the low-spatial-frequency nature of ice water clouds, unique tomography algorithms were developed using filtered back-projection methods and direct inversion methods that use Gaussian basis functions. With the availability of a priori knowledge of the mean droplet size and the total water content at some point in the measurement plane, the tomography system can provide near real-time in-situ quantitative full-field total water content data at a measurement plane approximately 5 feet upstream of the engine inlet. Results from ice crystal clouds in the PSL are presented. In addition to the optical tomography technique, laser sheet imaging has also been applied in the PSL to provide planar ice cloud uniformity and relative water content data during facility calibration before the tomography system was available and also as validation data for the tomography system. A comparison between the laser sheet system and light extinction tomography resulting data are also presented. Very good agreement of imaged intensity and water content is demonstrated for both techniques. Also, comparative studies between the two techniques show excellent agreement in calculation of bulk total water content averaged over the center of the pipe

    Measurement of the Inclusive Charm Cross Section at 4.03 GeV and 4.14 GeV

    Full text link
    The cross section for charmed meson production at s=4.03\sqrt{s} = 4.03 and 4.14 GeV has been measured with the Beijing Spectrometer. The measurement was made using 22.3 pb1pb^{-1} of e+ee^+e^- data collected at 4.03 GeV and 1.5 pb1pb^{-1} of e+ee^+e^- data collected at 4.14 GeV. Inclusive observed cross sections for the production of charged and neutral D mesons and momentum spectra are presented. Observed cross sections were radiatively corrected to obtain tree level cross sections. Measurements of the total hadronic cross section are obtained from the charmed meson cross section and an extrapolation of results from below the charm threshold.Comment: 11 pages, 13 figures. The top level tex file is paper.tex. It builds the paper from other tex files in this .tar and the .eps file

    Study of the P-wave charmonium state \chi_{cJ} in \psi(2S) decays

    Full text link
    The processes ψ(2S)γπ+π\psi(2S)\to \gamma \pi^+ \pi^-, γK+K\gamma K^+ K^- and γppˉ\gamma p \bar{p} have been studied using a sample of 3.7×1063.7 \times 10^6 produced ψ(2S)\psi(2S) decays. We determine the total width of the χc0\chi_{c0} to be Γχc0tot=14.3±2.0±3.0\Gamma^{tot}_{\chi_{c0}} = 14.3\pm 2.0\pm 3.0 MeV. We present the first measurement of the branching fraction B(χc0ppˉ)=(16.3±4.4±5.4)×105B(\chi_{c0} \to p \bar{p}) = (16.3 \pm 4.4 \pm 5.4)\times 10^{-5}, where the first error is statistical and the second one systematic. Branching fractions of χc0,2π+π\chi_{c0,2} \to \pi^+ \pi^- and K+KK^+ K^- are also reported.Comment: 10 pages, revtex, 3 figures, 2 table

    First Measurement of the Branching Fraction of the Decay psi(2S) --> tau tau

    Full text link
    The branching fraction of the psi(2S) decay into tau pair has been measured for the first time using the BES detector at the Beijing Electron-Positron Collider. The result is Bττ=(2.71±0.43±0.55)×103B_{\tau\tau}=(2.71\pm 0.43 \pm 0.55) \times 10^{-3}, where the first error is statistical and the second is systematic. This value, along with those for the branching fractions into e+e- and mu+mu of this resonance, satisfy well the relation predicted by the sequential lepton hypothesis. Combining all these values with the leptonic width of the resonance the total width of the psi(2S) is determined to be (252±37)(252 \pm 37) keV.Comment: 9 pages, 2 figure

    Measurement of ψ(2S)\psi(2S) decays to baryon pairs

    Full text link
    A sample of 3.95M ψ(2S)\psi(2S) decays registered in the BES detector are used to study final states containing pairs of octet and decuplet baryons. We report branching fractions for ψ(2S)ppˉ\psi(2S)\to p\bar{p}, ΛΛˉ\Lambda\bar{\Lambda}, Σ0Σˉ0\Sigma^0\bar{\Sigma}{}^0, ΞΞˉ+\Xi^-\bar{\Xi}{}^+, Δ++Δˉ\Delta^{++}\bar{\Delta}{}^{--}, Σ+(1385)Σˉ(1385)\Sigma^+(1385)\bar{\Sigma}{}^-(1385), Ξ0(1530)Ξˉ0(1530)\Xi^0(1530)\bar{\Xi}{}^0(1530), and ΩΩˉ+\Omega^-\bar{\Omega}{}^+. These results are compared to expectations based on the SU(3)-flavor symmetry, factorization, and perturbative QCD.Comment: 22 pages, 21 figures, 4 table

    Measurements of the Cross Section for e+e- -> hadrons at Center-of-Mass Energies from 2 to 5 GeV

    Get PDF
    We report values of R=σ(e+ehadrons)/σ(e+eμ+μ)R = \sigma(e^+e^-\to {hadrons})/\sigma(e^+e^-\to\mu^+\mu^-) for 85 center-of-mass energies between 2 and 5 GeV measured with the upgraded Beijing Spectrometer at the Beijing Electron-Positron Collider.Comment: 5 pages, 3 figure

    The Demonstration of a Light Extinction Tomography System at the NASA Glenn Research Center's Icing Research Tunnel

    Get PDF
    A prototype light extinction tomography system has been developed for acquiring real-time in-situ icing cloud uniformity and density measurements in the NASA Glenn Research Center's Icing Research Tunnel (IRT). These measurements are currently obtained through periodic manual calibrations of the IRT. These calibrations are time consuming and assume that cloud uniformity and density does not greatly vary between the periodic calibrations. It is envisioned that the new light extinction tomography system will provide the means to make these measurements in-situ in real-time and minimize the need for these manual calibrations. This new system uses the principle of light extinction tomography to measure the spray density and distribution in the test section. The prototype system was installed and successfully demonstrated in the Icing Research Tunnel in early 2018. Data sets were acquired for several standard spray and simulated fault conditions to assess system capability and sensitivity. This paper will describe the prototype light extinction system, the theory behind it, and the results of the demonstration test that was conducted in the IRT

    Measurement of the Total Cross Section for Hadronic Production by e+e- Annihilation at Energies between 2.6-5 Gev

    Get PDF
    Using the upgraded Beijing Spectrometer (BESII), we have measured the total cross section for e+ee^+e^- annihilation into hadronic final states at center-of-mass energies of 2.6, 3.2, 3.4, 3.55, 4.6 and 5.0 GeV. Values of RR, σ(e+ehadrons)/σ(e+eμ+μ)\sigma(e^+e^-\to {hadrons})/\sigma(e^+e^-\to\mu^+\mu^-), are determined.Comment: Submitted to Phys. Rev. Let

    Observation of a near-threshold enhancement in th p pbar mass spectrum from radiative J/psi-->gamma p pbar decays

    Full text link
    We observe a narrow enhancement near 2mp in the invariant mass spectrum of ppbar pairs from radiative J/psi-->gamma ppbar decays. The enhancement can be fit with either an S- or P-wave Breit Wigner fuction. In the case of the S-wave fit, the peak mass is below the 2mp threshold and the full width is less than 30 MeV. These mass and width values are not consistent with the properties of any known meson resonance.Comment: 5 pages, 4 figures, submitted to Phys. Rev. Let
    corecore