5 research outputs found

    Influence of Manufacturing Methods of Implant-Supported Crowns on External and Internal Marginal Fit: A Micro-CT Analysis

    No full text
    Aim. To evaluate the influence of different manufacturing methods of single implant-supported metallic crowns on the internal and external marginal fit through computed microtomography. Methods. Forty external hexagon implants were divided into 4 groups (n=8), according to the manufacturing method: GC, conventional casting; GI, induction casting; GP, plasma casting; and GCAD, CAD/CAM machining. The crowns were attached to the implants with insertion torque of 30 N·cm. The external (vertical and horizontal) marginal fit and internal fit were assessed through computed microtomography. Internal and external marginal fit data (μm) were submitted to a one-way ANOVA and Tukey’s test (α=.05). Qualitative evaluation of the images was conducted by using micro-CT. Results. The statistical analysis revealed no significant difference between the groups for vertical misfit (P=0.721). There was no significant difference (P>0.05) for the internal and horizontal marginal misfit in the groups GC, GI, and GP, but it was found for the group GCAD (P≤0.05). Qualitative analysis revealed that most of the samples of cast groups exhibited crowns underextension while the group GCAD showed overextension. Conclusions. The manufacturing method of the crowns influenced the accuracy of marginal fit between the prosthesis and implant. The best results were found for the crowns fabricated through CAD/CAM machining

    Evaluation of Stress Distribution in Endodontically Weakened Teeth Restored with Different Crown Materials: 3D-FEA Analysis

    No full text
    <div><p>Abstract This study evaluated the stress distribution in endodontically treated teeth, weakened (W) or not weakened (NW), restored with different materials of prosthetic crown using 3D-FEA. Models of a maxillary canine were constructed based on micro-CT images and divided into the groups: G1 (control) - sound tooth; G2 to G7 - endodontically treated teeth restored with glass fiber post (GFP); which G2 to G4 simulated NW root and G5 to G7 simulated W root. For crown material the teeth were restored with: G2 and G5: metallic coping and ceramic veneering, G3 and G6: zirconia coping and ceramic veneering, G4 and G7: alumina coping and ceramic veneering. Load of 180 N was applied at the incisal third of lingual surface at 45º. Models were supported by the periodontal ligament (x=y=z=0). The von Mises stress (VMS) values were calculated. The W teeth presented higher VMS at coping when compared to NW teeth and group G1 showed lower VMS value. For crown material, for both W or NW teeth, increasing VMS was found at metallic, zirconia and alumina coping, respectively. Metallic coping showed a better performance despite its unfavorable esthetics, suggesting as an appropriate material for prosthetic restoration of endodontically treated teeth.</p></div

    Erratum to: Guidelines for the use and interpretation of assays for monitoring autophagy (3rd edition) (Autophagy, 12, 1, 1-222, 10.1080/15548627.2015.1100356

    No full text
    non present

    Guidelines for the use and interpretation of assays for monitoring autophagy (3rd edition)

    No full text
    corecore