1,245 research outputs found
Why is the condensed phase of DNA preferred at higher temperature? DNA compaction in the presence of a multivalent cation
Upon the addition of multivalent cations, a giant DNA chain exhibits a large
discrete transition from an elongated coil into a folded compact state. We
performed single-chain observation of long DNAs in the presence of a
tetravalent cation (spermine), at various temperatures and monovalent salt
concentrations. We confirmed that the compact state is preferred at higher
temperatures and at lower monovalent salt concentrations. This result is
interpreted in terms of an increase in the net translational entropy of small
ions due to ionic exchange between higher and lower valence ions.Comment: 4pages,3figure
An Electron-Tracking Compton Telescope for a Survey of the Deep Universe by MeV gamma-rays
Photon imaging for MeV gammas has serious difficulties due to huge
backgrounds and unclearness in images, which are originated from incompleteness
in determining the physical parameters of Compton scattering in detection,
e.g., lack of the directional information of the recoil electrons. The recent
major mission/instrument in the MeV band, Compton Gamma Ray
Observatory/COMPTEL, which was Compton Camera (CC), detected mere
persistent sources. It is in stark contrast with 2000 sources in the GeV
band. Here we report the performance of an Electron-Tracking Compton Camera
(ETCC), and prove that it has a good potential to break through this stagnation
in MeV gamma-ray astronomy. The ETCC provides all the parameters of
Compton-scattering by measuring 3-D recoil electron tracks; then the Scatter
Plane Deviation (SPD) lost in CCs is recovered. The energy loss rate (dE/dx),
which CCs cannot measure, is also obtained, and is found to be indeed helpful
to reduce the background under conditions similar to space. Accordingly the
significance in gamma detection is improved severalfold. On the other hand, SPD
is essential to determine the point-spread function (PSF) quantitatively. The
SPD resolution is improved close to the theoretical limit for multiple
scattering of recoil electrons. With such a well-determined PSF, we demonstrate
for the first time that it is possible to provide reliable sensitivity in
Compton imaging without utilizing an optimization algorithm. As such, this
study highlights the fundamental weak-points of CCs. In contrast we demonstrate
the possibility of ETCC reaching the sensitivity below erg
cm s at 1 MeV.Comment: 19 pages, 12 figures, Accepted to the Astrophysical Journa
- …