    Lymph Node Characterization in Vivo Using Endoscopic Ultrasound Spectrum Analysis With Electronic Array Echo Endoscopes

    Get PDF
    Our purpose was to demonstrate the use of radiofrequency spectral analysis to distinguish between benign and malignant lymph nodes with data obtained using electronic array echo endoscopes, as we have done previously using mechanical echo endoscopes. In a prospective study, images were obtained from eight patients with benign-appearing lymph nodes and 11 with malignant lymph nodes, as verified by fine-needle aspiration. Midband fit, slope, intercept, correlation coefficient, and root-mean-square (RMS) deviation from a linear regression of the calibrated power spectra were determined and compared between the groups. Significant differences were observable for mean midband fit, intercept, and RMS deviation (t test P \u3c 0.05). For benign (n = 16) vs. malignant (n = 12) lymph nodes, midband fit and RMS deviation provided classification with 89 % accuracy and area under receiver operating characteristic (ROC) curve of 0.95 based on linear discriminant analysis. We concluded that the mean spectral parameters of the backscattered signals from electronic array echo endoscopy can provide a noninvasive method to quantitatively discriminate between benign and malignant lymph nodes

    Small bowel capsule endoscopy in patients with cardiac pacemakers and implantable cardioverter defibrillators: Outcome analysis using telemetry review

    No full text
    AIM: To determine if there were any interactions between cardiac devices and small bowel capsules secondary to electromagnetic interference (EMI) in patients who have undergone small bowel capsule endoscopy (SBCE)

    Characterization of the Pancreas in Vivo Using EUS Spectrum Analysis with Electronic Array Echoendoscopes

    No full text
    Background Spectral analysis of the radiofrequency (RF) signals that underlie grayscale EUS images has been used to provide quantitative, objective information about tissue histology. Objective Our purpose was to validate RF spectral analysis as a method to distinguish between chronic pancreatitis (CP) and pancreatic cancer (PC). Design and Setting A prospective study of eligible patients was conducted to analyze the RF data obtained by using electronic array echoendoscopes. Patients Pancreatic images were obtained by using electronic array echoendoscopes from 41 patients in a prospective study, including 15 patients with PC, 15 with CP, and 11 with a normal pancreas. Main Outcome Measurements Midband fit, slope, intercept, correlation coefficient, and root mean square deviation from a linear regression of the calibrated power spectra were determined and compared among the groups. Results Statistical analysis showed that significant differences were observable between groups for mean midband fit, intercept, and root mean square deviation (t test, P \u3c .05). Discriminant analysis of these parameters was then performed to classify the data. For CP (n = 15) versus PC (n = 15), the same parameters provided 83% accuracy and an area under the curve of 0.83. Limitations Moderate sample size and spatial averaging inherent in the technique. Conclusions This study shows that mean spectral parameters of the backscattered signals obtained by using electronic array echoendoscopes can provide a noninvasive method to quantitatively discriminate between CP and PC