11 research outputs found

    Automated bolus advisor control and usability study (ABACUS): does use of an insulin bolus advisor improve glycaemic control in patients failing multiple daily insulin injection (MDI) therapy? [NCT01460446]

    Get PDF
    BACKGROUND: People with T1DM and insulin-treated T2DM often do not follow and/or adjust their insulin regimens as needed. Key contributors to treatment non-adherence are fear of hypoglycaemia, difficulty and lack of self-efficacy associated with insulin dose determination. Because manual calculation of insulin boluses is both complex and time consuming, people may rely on empirical estimates, which can result in persistent hypoglycaemia and/or hyperglycaemia. Use of automated bolus advisors (BA) has been shown to help insulin pump users to more accurately meet prandial insulin dosage requirements, improve postprandial glycaemic excursions, and achieve optimal glycaemic control with an increased time within optimal range. Use of a BA containing an early algorithm based on sliding scales for insulin dosing has also been shown to improve HbA1c levels in people treated with multiple daily insulin injections (MDI). We designed a study to determine if use of an automated BA can improve clinical and psychosocial outcomes in people treated with MDI. METHODS/DESIGN: The Automated Bolus Advisor Control and Usability Study (ABACUS) is a 6-month, prospective, randomised, multi-centre, multi-national trial to determine if automated BA use improves glycaemic control as measured by a change in HbA1c in people using MDI with elevated HbA1c levels (#62;7.5%). A total of 226 T1DM and T2DM participants will be recruited. Anticipated attrition of 20% will yield a sample size of 90 participants, which will provide #62;80% power to detect a mean difference of 0.5%, with SD of 0.9%, using a one-sided 5% t-test, with 5% significance level. Other measures of glycaemic control, self-care behaviours and psychosocial issues will also be assessed. DISCUSSION: It is critical that healthcare providers utilise available technologies that both facilitate effective glucose management and address concerns about safety and lifestyle. Automated BAs may help people using MDI to manage their diabetes more effectively and minimise the risk of long-term diabetes related complications. Findings from a recent study suggest that BA use positively addresses both safety and lifestyle concerns; however, randomised trials are needed to confirm these perceptions and determine whether bolus advisor use improves clinical outcomes. Our study is designed to make these assessments. TRIAL REGISTRATION: NCT0146044

    Therapy-Related Explants After Spinal Cord Stimulation: Results of an International Retrospective Chart Review Study

    No full text
    Objectives: Clinical trials of spinal cord stimulation (SCS) have largely focused on conversion from trial to permanent SCS and the first years after implant. This study evaluates the association of type of SCS and patient characteristics with longer-term therapy-related explants. Materials and Methods: Implanting centers in three European countries conducted a retrospective chart review of SCS systems implanted from 2010 to 2013. Ethics approval or waiver was obtained, and informed consent was not required. The chart review recorded implants, follow-up visits, and date and reasons for any explants through mid-2016. Results are presented using Cox regression to determine factors associated with explant for inadequate pain relief. Results: Four implanting centers in three countries evaluated 955 implants, with 8720 visits over 2259 years of follow-up. Median age was 53 years; 558 (58%) were female. Explant rate was 7.9% per year. Over half (94 of 180) of explants were for inadequate pain relief, including 32/462 (6.9%) of implants with conventional nonrechargeable SCS, 37/329 (11.2%) with conventional rechargeable and 22/155 (14.2%) with high-frequency (10 kHz) rechargeable SCS. A higher explant rate was found in univariate regression for conventional rechargeable (HR 1.98, p=0.005) and high-frequency stimulation (HR 1.79, p=0.035) than nonrechargeable SCS. After covariate adjustment, the elevated explant rate persisted for conventional rechargeable SCS (HR 1.95, p=0.011), but was not significant for high-frequency stimulation (HR 1.71, p=0.069). Conclusions: This international, real-world study found higher explant rates for conventional rechargeable and high-frequency SCS than nonrechargeable systems. The increased rate for conventional rechargeable stimulation persisted after covariate adjustmen

    Automated bolus advisor control and usability study (ABACUS): does use of an insulin bolus advisor improve glycaemic control in patients failing multiple daily insulin injection (MDI) therapy? [NCT01460446]

    No full text
    Abstract Background People with T1DM and insulin-treated T2DM often do not follow and/or adjust their insulin regimens as needed. Key contributors to treatment non-adherence are fear of hypoglycaemia, difficulty and lack of self-efficacy associated with insulin dose determination. Because manual calculation of insulin boluses is both complex and time consuming, people may rely on empirical estimates, which can result in persistent hypoglycaemia and/or hyperglycaemia. Use of automated bolus advisors (BA) has been shown to help insulin pump users to more accurately meet prandial insulin dosage requirements, improve postprandial glycaemic excursions, and achieve optimal glycaemic control with an increased time within optimal range. Use of a BA containing an early algorithm based on sliding scales for insulin dosing has also been shown to improve HbA1c levels in people treated with multiple daily insulin injections (MDI). We designed a study to determine if use of an automated BA can improve clinical and psychosocial outcomes in people treated with MDI. Methods/design The Automated Bolus Advisor Control and Usability Study (ABACUS) is a 6-month, prospective, randomised, multi-centre, multi-national trial to determine if automated BA use improves glycaemic control as measured by a change in HbA1c in people using MDI with elevated HbA1c levels (#62;7.5%). A total of 226 T1DM and T2DM participants will be recruited. Anticipated attrition of 20% will yield a sample size of 90 participants, which will provide #62;80% power to detect a mean difference of 0.5%, with SD of 0.9%, using a one-sided 5% t-test, with 5% significance level. Other measures of glycaemic control, self-care behaviours and psychosocial issues will also be assessed. Discussion It is critical that healthcare providers utilise available technologies that both facilitate effective glucose management and address concerns about safety and lifestyle. Automated BAs may help people using MDI to manage their diabetes more effectively and minimise the risk of long-term diabetes related complications. Findings from a recent study suggest that BA use positively addresses both safety and lifestyle concerns; however, randomised trials are needed to confirm these perceptions and determine whether bolus advisor use improves clinical outcomes. Our study is designed to make these assessments. Trial registration NCT01460446</p

    Use of an integrated strip-free blood glucose monitoring system increases frequency of self-monitoring and improves glycemic control: Results from the ExAct study

    Get PDF
    Aims We investigated the impact of using an integrated, strip-free system compared to the use of single-strip systems on testing frequency and glycemic control in individuals with insulin-treated diabetes. Methods This multinational, comparative, cluster-randomized, observational study included 311 patients with type 1 and insulin-treated type 2 diabetes who were performing SMBG at suboptimal frequencies. Sites were cluster-randomized to “integrated strip-free” system (EXP group) or any “single-strip” system (CNL group). Testing frequency and HbA1c were measured at baseline, 12 weeks and 24 weeks. Results At week 24, the EXP group showed an increase in SMBG frequency from baseline of 4.17 tests/week (95% CI 2.76, 5.58) compared with an increase of 0.53 tests/week (95% CI −0.73, 1.79) among CNL patients, resulting in a between-group difference of 3.63 tests/week (p < 0.0002). Mixed-effects models for repeated measurements (MMRM) controlling for baseline frequency of testing, country and clinical site confirmed a higher SMBG testing frequency in the EXP group compared to the CNL group, with a between-group difference of 2.70 tests/week (p < 0.01). Univariate analysis showed greater HbA1c reductions in the EXP group than CNL group: −0.44% (95% CI −0.59, −0.29) vs. −0.13% (95% CI −0.27, 0.01), respectively, p < 0.0002. MMRM analyses confirmed these HbA1c reductions. A greater percentage of EXP than CNL patients achieved HbA1c reductions of ≥0.5%: 45.1% vs. 29.1%, respectively, p < 0.01. Conclusions The use of an integrated, strip-free SMBG system improved testing adherence and was associated with improvements in glycemic control

    sj-tif-2-dst-10.1177_19322968241234055 – Supplemental material for A Three-Arm Randomized Controlled Study Comparing Patient-Reported Outcomes in People With Type 1 Diabetes Using Continuous Subcutaneous Insulin Infusion or Multiple Daily Injections

    No full text
    Supplemental material, sj-tif-2-dst-10.1177_19322968241234055 for A Three-Arm Randomized Controlled Study Comparing Patient-Reported Outcomes in People With Type 1 Diabetes Using Continuous Subcutaneous Insulin Infusion or Multiple Daily Injections by Katharine Barnard-Kelly, Florian Thienel, Julia K. Mader, Nick Oliver, Edward Franek, Iris Vesper, Nicole Dagenbach, Gerhard Vogt, Tobias Etter and Thomas Künsting in Journal of Diabetes Science and Technology</p

    sj-docx-1-dst-10.1177_19322968241234055 – Supplemental material for A Three-Arm Randomized Controlled Study Comparing Patient-Reported Outcomes in People With Type 1 Diabetes Using Continuous Subcutaneous Insulin Infusion or Multiple Daily Injections

    No full text
    Supplemental material, sj-docx-1-dst-10.1177_19322968241234055 for A Three-Arm Randomized Controlled Study Comparing Patient-Reported Outcomes in People With Type 1 Diabetes Using Continuous Subcutaneous Insulin Infusion or Multiple Daily Injections by Katharine Barnard-Kelly, Florian Thienel, Julia K. Mader, Nick Oliver, Edward Franek, Iris Vesper, Nicole Dagenbach, Gerhard Vogt, Tobias Etter and Thomas Künsting in Journal of Diabetes Science and Technology</p

    Refractory Epstein-Barr Virus (EBV)-related post-transplant lymphoproliferative disease

    No full text
    Post-transplant lymphoproliferative disease (PTLD) represents a serious complication following allogeneic hematopoietic stem cell transplantation (alloHSCT). Previously, survival rates of PTLD have improved due to the introduction of rituximab. However, reports on curative management of refractory PTLD are scarce. Today, there is no consensus how to treat rituximab-refractory PTLD, especially in highly aggressive disease. Here, we describe successful management of refractory EBV-associated PTLD, specifically DLBCL, with combined brentuximab vedotin and third-party EBV-specific T-cells in a multidisciplinary treatment approach

    Use of an integrated strip-free blood glucose monitoring system increases frequency of self-monitoring and improves glycemic control: Results from the ExAct study

    No full text
    Aims: We investigated the impact of using an integrated, strip-free system compared to the use of single-strip systems on testing frequency and glycemic control in individuals with insulin-treated diabetes. Methods: This multinational, comparative, cluster-randomized, observational study included 311 patients with type 1 and insulin-treated type 2 diabetes who were performing SMBG at suboptimal frequencies. Sites were cluster-randomized to “integrated strip-free” system (EXP group) or any “single-strip” system (CNL group). Testing frequency and HbA1c were measured at baseline, 12 weeks and 24 weeks. Results: At week 24, the EXP group showed an increase in SMBG frequency from baseline of 4.17 tests/week (95% CI 2.76, 5.58) compared with an increase of 0.53 tests/week (95% CI −0.73, 1.79) among CNL patients, resulting in a between-group difference of 3.63 tests/week (p < 0.0002). Mixed-effects models for repeated measurements (MMRM) controlling for baseline frequency of testing, country and clinical site confirmed a higher SMBG testing frequency in the EXP group compared to the CNL group, with a between-group difference of 2.70 tests/week (p < 0.01). Univariate analysis showed greater HbA1c reductions in the EXP group than CNL group: −0.44% (95% CI −0.59, −0.29) vs. −0.13% (95% CI −0.27, 0.01), respectively, p < 0.0002. MMRM analyses confirmed these HbA1c reductions. A greater percentage of EXP than CNL patients achieved HbA1c reductions of ≥0.5%: 45.1% vs. 29.1%, respectively, p < 0.01. Conclusions: The use of an integrated, strip-free SMBG system improved testing adherence and was associated with improvements in glycemic control
    corecore