22 research outputs found

    The role of open-air inhalatoria in the air quality improvement in spa towns

    Full text link
    Objectives: The present study was aimed at evaluating microbiological contamination of air in Ciechocinek and Ino­wro­cław – Polish lowland spa towns. Additionally, the impact of open-air inhalatoria on the quality of air was evaluated. Material and Methods: Air samples were collected seasonally in the urban areas, in the recreation areas and in the vicinity of inhalatoria in both towns using impaction. The numbers of mesophilic bacteria, staphylococci, hemolytic bacteria and actinomycetes were determined on media according to the Polish Standard PN-86/Z-04111/02. The number of moulds was determined on media according to the Polish Standard PN-86/Z-04111/03. Results: While the highest numbers of microorganisms were noted at the sites located in the urban areas, the lowest numbers were noted in the vicinity of the open-air inhalatoria. In all the investigated air samples the values of bioaerosol concentrations were below the recommended TLVs (≤ 5000 CFU×m–3 for both bacteria and fungi in outdoor environments). Location of the sampling site was invariably a decisive factor in determining the number of microorganisms in the air. Conclusions: The aerosol which is formed in the open-air inhalatoria has a positive influence on microbiological air quality. Owing to a unique microclimate and low air contamination, Ciechocinek and Inowrocław comply with all necessary requirements set for health resorts specializing in treating upper respiratory tract infections

    Children’s residential exposure to selected allergens and microbial indicators: endotoxins and (1→3)-β-D-glucans

    Full text link
    Objectives: The study was aimed at assessment of exposure to endotoxins, (1→3)-β-D-glucans and mite, cockroach, cat, dog allergens present in settled dust in premises of children as agents which may be significantly correlated with the occurrence of allergic symptoms and diseases in children. Materials and Methods: The study covered 50 homes of one- or two-year-old children in Poland. Samples of settled dust were taken from the floor and the child's bed. The levels of (1→3)-β-D-glucans (floor), endotoxins (floor) and allergens of mite, cat, dog and cockroach (floor and bed) were analyzed. Results: Average geometric concentrations (geometric standard deviation) of endotoxins, (1→3)-β-D-glucans, Der p1, Fel d1, Can f1 and Bla g1 in children homes were on the floor 42 166.0 EU/g (3.2), 20 478.4 ng/g (2.38), 93.9 ng/g (6.58), 119.8 ng/g (13.0), 288.9 ng/g (3.4), 0.72 U/g (4.4) and in their beds (only allergens) 597.8 ng/g (14.2), 54.1 ng/g (4.4), 158.6 ng/g (3.1) 0.6 U/g (2.9), respectively. When the floor was covered with the carpet, higher concentrations of endotoxins, (1→3)-β-D-glucans and allergens (each type) were found in the settled dust (p < 0.05). The trend was opposite in case of allergens (except dog) analyzed from bed dust and significantly higher concentrations were found in the rooms with smooth floor (p < 0.05). Conclusions: Among the analyzed factors only the type of floor significantly modified both the level of biological indicators and allergens. The results of this study could be the base for verifying a hypothesis that carpeting may have a protective role against high levels of cockroach, dog and cat allergens

    Abridged version of the AWMF guideline for the medical clinical diagnostics of indoor mould exposure

    Get PDF
    corecore