46 research outputs found

    High Accuracy Decoding of Movement Target Direction in Non-Human Primates Based on Common Spatial Patterns of Local Field Potentials

    Get PDF
    BACKGROUND: The current development of brain-machine interface technology is limited, among other factors, by concerns about the long-term stability of single- and multi-unit neural signals. In addition, the understanding of the relation between potentially more stable neural signals, such as local field potentials, and motor behavior is still in its early stages. METHODOLOGY/PRINCIPAL FINDINGS: We tested the hypothesis that spatial correlation patterns of neural data can be used to decode movement target direction. In particular, we examined local field potentials (LFP), which are thought to be more stable over time than single unit activity (SUA). Using LFP recordings from chronically implanted electrodes in the dorsal premotor and primary motor cortex of non-human primates trained to make arm movements in different directions, we made the following observations: (i) it is possible to decode movement target direction with high fidelity from the spatial correlation patterns of neural activity in both primary motor (M1) and dorsal premotor cortex (PMd); (ii) the decoding accuracy of LFP was similar to the decoding accuracy obtained with the set of SUA recorded simultaneously; (iii) directional information varied with the LFP frequency sub-band, being greater in low (0.3-4 Hz) and high (48-200 Hz) frequency bands than in intermediate bands; (iv) the amount of directional information was similar in M1 and PMd; (v) reliable decoding was achieved well in advance of movement onset; and (vi) LFP were relatively stable over a period of one week. CONCLUSIONS/SIGNIFICANCE: The results demonstrate that the spatial correlation patterns of LFP signals can be used to decode movement target direction. This finding suggests that parameters of movement, such as target direction, have a stable spatial distribution within primary motor and dorsal premotor cortex, which may be used for brain-machine interfaces

    Elimination of Pseudo-HFOs in IEEG Using Sparse Representation and Random Forest Classifier

    Get PDF
    High-Frequency Oscillation (HFO) is a promising biomarker of the epileptogenic zone. However, sharp artifacts might easily pass the conventional HFO detectors as real HFOs and reduce the seizure onset zone (SOZ) localization. We hypothesize that, unlike pseudo-HFOs, which originates from artifacts with sharp changes or arbitrary waveform characteristic, real HFOs could be represented by a limited number of oscillatory waveforms. Accordingly, to distinguish true ones from pseudo-HFOs, we established a new classification method based on sparse representation of candidate events that passed an initial detector with high sensitivity but low specificity. Specifically, using the Orthogonal Matching Pursuit (OMP) and a redundant Gabor dictionary, each event was represented sparsely in an iterative fashion. The approximation error was estimated over 30 iterations which were concatenated to form a 30-dimensional feature vector and fed to a random forest classifier. Based on the selected dictionary elements, our method can further classify HFOs into Ripples (R) and Fast Ripples (FR). In this scheme, two experts visually inspected 2075 events captured in iEEG recordings from 5 different subjects and labeled them as true-HFO or Pseudo-HFO. We reached 90.22% classification accuracy in labeled events and a 21.16% SOZ localization improvement compared to the conventional amplitude-threshold-based detector. Our sparse representation framework also classified the detected HFOs into R and FR subcategories. We reached 91.24% SOZ accuracy with the detected R+FR events

    A Sparse Representation Strategy to Eliminate Pseudo-HFO Events From Intracranial EEG for Seizure Onset Zone Localization

    Get PDF
    Objective. High-frequency oscillations (HFOs) are considered a biomarker of the epileptogenic zone in intracranial EEG recordings. However, automated HFO detectors confound true oscillations with spurious events caused by the presence of artifacts. Approach. We hypothesized that, unlike pseudo-HFOs with sharp transients or arbitrary shapes, real HFOs have a signal characteristic that can be represented using a small number of oscillatory bases. Based on this hypothesis using a sparse representation framework, this study introduces a new classification approach to distinguish true HFOs from the pseudo-events that mislead seizure onset zone (SOZ) localization. Moreover, we further classified the HFOs into ripples and fast ripples by introducing an adaptive reconstruction scheme using sparse representation. By visualizing the raw waveforms and time-frequency representation of events recorded from 16 patients, three experts labelled 6400 candidate events that passed an initial amplitude-threshold-based HFO detector. We formed a redundant analytical multiscale dictionary built from smooth oscillatory Gabor atoms and represented each event with orthogonal matching pursuit by using a small number of dictionary elements. We used the approximation error and residual signal at each iteration to extract features that can distinguish the HFOs from any type of artifact regardless of their corresponding source. We validated our model on sixteen subjects with thirty minutes of continuous interictal iEEG recording from each. Main Results. We showed that the accuracy of SOZ detection after applying our method was significantly improved. In particular, we achieved a 96.65% classification accuracy in labelled events and a 17.57% improvement in SOZ detection on continuous data. Our sparse representation framework can also distinguish between ripples and fast ripples. Significance. We show that by using a sparse representation approach we can remove the pseudo-HFOs from the pool of events and improve the reliability of detected HFOs in large data sets and minimize manual artifact elimination

    Benchmarking signal quality and spatiotemporal distribution of interictal spikes in prolonged human iEEG recordings using CorTec wireless brain interchange

    Get PDF
    Neuromodulation through implantable pulse generators (IPGs) represents an important treatment approach for neurological disorders. While the field has observed the success of state-of-the-art interventions, such as deep brain stimulation (DBS) or responsive neurostimulation (RNS), implantable systems face various technical challenges, including the restriction of recording from a limited number of brain sites, power management, and limited external access to the assessed neural data in a continuous fashion. To the best of our knowledge, for the first time in this study, we investigated the feasibility of recording human intracranial EEG (iEEG) using a benchtop version of the Brain Interchange (BIC) unit of CorTec, which is a portable, wireless, and externally powered implant with sensing and stimulation capabilities. We developed a MATLAB/SIMULINK-based rapid prototyping environment and a graphical user interface (GUI) to acquire and visualize the iEEG captured from all 32 channels of the BIC unit. We recorded prolonged iEEG (~ 24 h) from three human subjects with externalized depth leads using the BIC and commercially available clinical amplifiers simultaneously in the epilepsy monitoring unit (EMU). The iEEG signal quality of both streams was compared, and the results demonstrated a comparable power spectral density (PSD) in all the systems in the low-frequency band (\u3c 80 Hz). However, notable differences were primarily observed above 100 Hz, where the clinical amplifiers were associated with lower noise floor (BIC-17 dB vs. clinical amplifiers \u3c  - 25 dB). We employed an established spike detector to assess and compare the spike rates in each iEEG stream. We observed over 90% conformity between the spikes rates and their spatial distribution captured with BIC and clinical systems. Additionally, we quantified the packet loss characteristic in the iEEG signal during the wireless data transfer and conducted a series of simulations to compare the performance of different interpolation methods for recovering the missing packets in signals at different frequency bands. We noted that simple linear interpolation has the potential to recover the signal and reduce the noise floor with modest packet loss levels reaching up to 10%. Overall, our results indicate that while tethered clinical amplifiers exhibited noticeably better noise floor above 80 Hz, epileptic spikes can still be detected successfully in the iEEG recorded with the externally powered wireless BIC unit opening the road for future closed-loop neuromodulation applications with continuous access to brain activity

    Intraoperative Language Mapping Guided by Real-Time Visualization of Gamma Band Modulation Electrocorticograms: Case Report and Proof of Concept

    Get PDF
    BACKGROUND: Electrocorticography (ECoG) language mapping is often performed extraoperatively, frequently involves offline processing, and relationships with direct cortical stimulation (DCS) remain variable. We sought to determine the feasibility and preliminary utility of an intraoperative language mapping approach guided by real-time visualization of electrocorticograms. METHODS: A patient with astrocytoma underwent awake craniotomy with intraoperative language mapping, utilizing a dual iPad stimulus presentation system coupled to a real-time neural signal processing platform capable of both ECoG recording and delivery of DCS. Gamma band modulations in response to 4 language tasks at each electrode were visualized in real-time. Next, DCS was conducted for each neighboring electrode pair during language tasks. RESULTS: All language tasks resulted in strongest heat map activation at an electrode pair in the anterior to mid superior temporal gyrus. Consistent speech arrest during DCS was observed for Object and Action naming tasks at these same electrodes, indicating good correspondence with ECoG heat map recordings. This region corresponded well with posterior language representation via preoperative functional MRI. CONCLUSIONS: Intraoperative real-time visualization of language task-based ECoG gamma band modulation is feasible and may help identify targets for DCS. If validated, this may improve the efficiency and accuracy of intraoperative language mapping

    A space-time-frequency analysis approach for the classification motor imagery EEG recordings in a brain computer interface task

    No full text
    28th Annual International Conference of the IEEE-Engineering-in-Medicine-and-Biology-Society -- AUG 30-SEP 03, 2006 -- New York, NYWOS: 000247284703190We introduce an adaptive space time frequency analysis to extract and classify subject specific brain oscillations induced by motor imagery in a Brain Computer Interface task. The introduced method requires no prior knowledge of the reactive frequency bands, their temporal behavior or cortical locations. The algorithm implements an arbitrary time-frequency segmentation procedure by using a flexible local discriminant base algorithm for given multichannel brain activity recordings to extract subject specific ERD and ERS patterns. Extracted time-frequency features are processed by principal component analysis to reduce the feature set which is highly correlated due to volume conduction and the neighbor cortical regions. The reduced feature set is then fed to a linear discriminant analysis for classification. We give experimental results for 9 subjects to show the superior performance of the proposed method where the classification accuracy varied between 76.4% and 96.81% and the average classification accuracy was 84.9%.IEEE Engn Med & Biol SocNational Scientific Research Council of Turkey (TUBITAK)Turkiye Bilimsel ve Teknolojik Arastirma Kurumu (TUBITAK)This work is supported by National Scientific Research Council of Turkey (TUBITAK)
    corecore