8 research outputs found

    Preparation and evaluation of sufficiently homogeneous and stable reference materials for priority hazardous substances in whole water

    No full text
    We have prepared and evaluated three whole water test materials containing eight polycyclic aromatic hydrocarbons (PAHs), six polybrominated diphenyl ethers (PBDEs) and tributyltin (TBT) with respect to homogeneity and short-term stability. The test materials were used as samples in two inter-laboratory comparisons. The materials were composed of natural mineral water and model suspended particulate matter (SPM) containing the target compounds at ng L-1 levels. The expanded uncertainty of the estimated mass concentrations in the final test materials was obtained by combining contributions from the homogeneity, the stability and the model-SPM characterization. The whole water materials were sufficiently homogeneous and stable at 4 °C for their intended use. Twelve out of fifteen investigated target parameters could be assessed to be present with a relative combined expanded uncertainty below 25 %. The outcome of the two inter-laboratory comparisons confirmed the good quality of the test materials and the level of uncertainties associated with the estimated mass concentrations. These findings are an important contribution towards the development of whole water matrix reference materials certified for PAH, PBDE and TBT in support of the Water Framework Directive of the European Union.JRC.D.2-Standards for Innovation and sustainable Developmen

    Interaction of 15 priority substances for water monitoring at ng L-1 levels with glass-, aluminium- and fluorinated polyethylene bottles for the containment of water reference materials

    No full text
    Certified water reference materials (CRMs) are currently not available for most of the hydrophobic organic pollutants listed in the EU Water Framework Directive (WFD). To find the most suitable container type for subsequent reference material productions, feasibility studies for the preparation of waters with polycyclic aromatic hydrocarbons (PAHs), polybrominated diphenyl ethers (PBDEs) and tributyltin (TBT) close to Environmental Quality Standards (EQS) in water have been performed. Due to the hydrophobic nature of these compounds and their tendency to adsorb onto container-walls, an adequate selection of the most appropriate material for containment, storage and transport of water reference materials is crucial. Three different materials (aluminium, amber glass and fluorinated polyethylene, FPE) and three volume ranges (500/600 mL, 1000/1200 mL and 2000/3000 mL) were tested at ng L-1 level of the target compounds. FPE shows by far the highest loss of analytes due to adsorption onto the container walls for all compounds studied. Aluminium and glass are equally suited for PAHs and PBDEs, but aluminium is unsuitable as container material for TBT due to acid cleaning requirements. The volume of the containers had no dramatic effect on the adsorption behaviour of target compounds for the different volumes tested.JRC.D.2-Standards for Innovation and sustainable Developmen

    Novel concepts for preparation of reference materials as whole water samples for priority substances at nanogram-per- liter level using model suspended particulate matter and humic acids

    No full text
    One of the unresolved issues of the European Water Framework Directive is the unavailability of realistic water reference materials for the organic priority pollutants at low ng L-1 concentrations. In the present study three different types of ready-to-use water test materials were developed for polycyclic aromatic hydrocarbons (PAHs), poly brominated diphenyl ethers (PBDEs) and tributyltin (TBT) at ng L-1 levels. The first type simulated the dissolved phase in the water and comprised of a solution of humic acids (HA) at 5 mg/L dissolved organic carbon (DOC) and a spike of the target compounds. The second type of water sample incorporated the particulate phase in water. To this end model suspended particulate matter (SPM) with a realistic particle size was produced by jet milling soil and sediments containing known amounts of PAHs, PBDEs and TBT and added as slurry to mineral water. The most complex test materials mimicked “whole water” consequently containing both phases, the model SPM and the HA solution with the target analytes strongly bound to the SPM. In this paper the development of concepts, processing of the starting materials, characterization of the HA and model SPMs as well as results for homogeneity and stability testing of the ready-to-use test materials are described in detail.JRC.D.2-Standards for Innovation and sustainable Developmen

    An interlaboratory comparison on whole water samples

    No full text
    The European Water Framework Directive 2000/60/EC requires monitoring of organic priority pollutants in so called “whole water” samples, i.e. in aqueous non-filtered samples that contain natural colloidal and suspended particulate matter. Colloids and suspended particles in the liquid phase constitute a challenge for sample homogeneity and stability. Within the joint research project ENV08 “Traceable measurements for monitoring critical pollutants under the European Water Framework Directive 2000/60/EC” whole water test materials were developed by spiking defined amounts of aqueous slurries of ultra-finely milled contaminated soil or sediment and aqueous solutions of humic acid into a natural mineral water matrix. This paper presents the results of an European-wide interlaboratory comparison (ILC) using this type of test materials. Target analytes were tributyl tin, polybrominated diphenyl ethers and polycyclic aromatic hydrocarbons in the ng/L concentration range. Results of the ILC indicate that the produced materials are sufficiently homogeneous and stable to serve as samples for e.g. proficiency testing or method validation. To our knowledge, this is the first time that ready to use water materials with a defined amount of suspended particulate and colloidal matter have been applied as test samples in an interlaboratory exercise. These samples meet the requirements of the European Water Framework Directive. Previous proficiency testing schemes mainly employed filtered water samples fortified with a spike of the target analyte in a water-miscible organic solvent.JRC.D.2-Standards for Innovation and sustainable Developmen
    corecore