4,871 research outputs found

    Development and validation of the ACE tool: Assessing medical trainees' competency in evidence based medicine

    Get PDF
    BACKGROUND: While a variety of instruments have been developed to assess knowledge and skills in evidence based medicine (EBM), few assess all aspects of EBM - including knowledge, skills attitudes and behaviour - or have been psychometrically evaluated. The aim of this study was to develop and validate an instrument that evaluates medical trainees’ competency in EBM across knowledge, skills and attitude. METHODS: The ‘Assessing Competency in EBM’ (ACE) tool was developed by the authors, with content and face validity assessed by expert opinion. A cross-sectional sample of 342 medical trainees representing ‘novice’, ‘intermediate’ and ‘advanced’ EBM trainees were recruited to complete the ACE tool. Construct validity, item difficulty, internal reliability and item discrimination were analysed. RESULTS: We recruited 98 EBM-novice, 108 EBM-intermediate and 136 EBM-advanced participants. A statistically significant difference in the total ACE score was observed and corresponded to the level of training: on a 0-15-point test, the mean ACE scores were 8.6 for EBM-novice; 9.5 for EBM-intermediate; and 10.4 for EBM-advanced (p < 0.0001). Individual item discrimination was excellent (Item Discrimination Index ranging from 0.37 to 0.84), with internal reliability consistent across all but three items (Item Total Correlations were all positive ranging from 0.14 to 0.20). CONCLUSION: The 15-item ACE tool is a reliable and valid instrument to assess medical trainees’ competency in EBM. The ACE tool provides a novel assessment that measures user performance across the four main steps of EBM. To provide a complete suite of instruments to assess EBM competency across various patient scenarios, future refinement of the ACE instrument should include further scenarios across harm, diagnosis and prognosis

    Domain wall displacement in Py square ring for single nanometric magnetic bead detection

    Full text link
    A new approach based on the domain wall displacement in confined ferromagnetic nanostructures for attracting and sensing a single nanometric magnetic particles is presented. We modeled and experimentally demonstrated the viability of the approach using an anisotropic magnetoresistance device made by a micron-size square ring of Permalloy designed for application in magnetic storage. This detection concept can be suitable to biomolecular recognition, and in particular to single molecule detection.Comment: 8pages, 3figure

    Moisture Content in Drying Wood Using Direct Scanning Gamma-Ray Densitometry

    Get PDF
    The distribution of moisture content in specimens of Eucalyptus regnans at various stages of drying from the green state has been measured using a direct scanning gamma-ray densitometer. Densitometry results obtained using 59.5 keV gamma-ray photons were compared with data obtained from matched specimens using a conventional slicing and weighing technique. Preliminary results of a shrinkage distribution analysis are presented for the first time. A detailed discussion of the theoretical and experimental aspects of the scanning densitometry technique is given together with a description of the instrument constructed for this work

    Measuring frequency fluctuations in nonlinear nanomechanical resonators

    Full text link
    Advances in nanomechanics within recent years have demonstrated an always expanding range of devices, from top-down structures to appealing bottom-up MoS2_2 and graphene membranes, used for both sensing and component-oriented applications. One of the main concerns in all of these devices is frequency noise, which ultimately limits their applicability. This issue has attracted a lot of attention recently, and the origin of this noise remains elusive up to date. In this Letter we present a very simple technique to measure frequency noise in nonlinear mechanical devices, based on the presence of bistability. It is illustrated on silicon-nitride high-stress doubly-clamped beams, in a cryogenic environment. We report on the same T/fT/f dependence of the frequency noise power spectra as reported in the literature. But we also find unexpected {\it damping fluctuations}, amplified in the vicinity of the bifurcation points; this effect is clearly distinct from already reported nonlinear dephasing, and poses a fundamental limit on the measurement of bifurcation frequencies. The technique is further applied to the measurement of frequency noise as a function of mode number, within the same device. The relative frequency noise for the fundamental flexure δf/f0\delta f/f_0 lies in the range 0.5−0.01 0.5 - 0.01~ppm (consistent with literature for cryogenic MHz devices), and decreases with mode number in the range studied. The technique can be applied to {\it any types} of nano-mechanical structures, enabling progresses towards the understanding of intrinsic sources of noise in these devices.Comment: Published 7 may 201

    Dipole-induced vortex ratchets in superconducting films with arrays of micromagnets

    Full text link
    We investigate the transport properties of superconducting films with periodic arrays of in-plane magnetized micromagnets. Two different magnetic textures are studied: a square array of magnetic bars and a close-packed array of triangular microrings. As confirmed by MFM imaging, the magnetic state of both systems can be adjusted to produce arrays of almost point-like magnetic dipoles. By carrying out transport measurements with ac drive, we observed experimentally a recently predicted ratchet effect induced by the interaction between superconducting vortices and the magnetic dipoles. Moreover, we find that these magnetic textures produce vortex-antivortex patterns, which have a crucial role on the transport properties of this hybrid system.Comment: 4 pages, 4 figure
    • …
    corecore