86 research outputs found
Imaging in-stent restenosis: an inexpensive, reliable, and rapid preclinical model.
Preclinical models of restenosis are essential to unravel the pathophysiological processes that lead to in-stent restenosis and to optimize existing and future drug-eluting stents. A variety of antibodies and transgenic and knockout strains are available in rats. Consequently, a model for in-stent restenosis in the rat would be convenient for pathobiological and pathophysiological studies. In this video, we present the full procedure and pit-falls of a rat stent model suitable for high throughput stent research. We will show the surgical procedure of stent deployment, and the assessment of in-stent restenosis using the most elegant technique of OCT (Optical Coherence Tomography). This technique provides high accuracy in assessing plaque CSAs (cross section areas) and correlates well with histological sections, which require special and time consuming embedding and sectioning techniques. OCT imaging further allows longitudinal monitoring of the development of in-stent restenosis within the same animal compared to one-time snapshots using histology
The Representative Porcine Model for Human Cardiovascular Disease
To improve human health, scientific discoveries must be translated into practical applications. Inherent in the development of these technologies is the role of preclinical testing using animal models. Although significant insight into the molecular and cellular basis has come from small animal models, significant differences exist with regard to cardiovascular characteristics between these models and humans. Therefore, large animal models are essential to develop the discoveries from murine models into clinical therapies and interventions.
This paper will provide an overview of the more frequently used large animal models, especially porcine models for preclinical studies
Fundamental Wire Technique and Current Standard Strategy of Percutaneous Intervention for Chronic Total Occlusion With Histopathological Insights
Currently, successful treatment of chronic total occlusion (CTO) seems markedly improved, due to several new techniques and dedicated device developments. However, this improved success rate is often limited to procedures performed by skilled, highly experienced operators. To improve the overall success rate of percutaneous coronary intervention of CTO from a worldwide perspective, a deeper understanding of CTO histopathology might offer insights into the development of new techniques and procedural strategies. In this review, CTO histopathology and wire techniques are discussed on the basis of the fundamental concepts of antegrade and retrograde approaches. Although details pertaining to wire manipulation are very difficult to explain objectively, we tried to describe this as best as possible in this article. Finally, a systematic review of the current standard CTO strategy is provided. Hopefully, this article will enhance the understanding of this complex procedure and, consequently, promote safe and effective CTO-percutaneous coronary intervention for patients who present with this challenging lesion subset
Evaluation and Treatment of Patients With Lower Extremity Peripheral Artery Disease Consensus Definitions From Peripheral Academic Research Consortium (PARC)
The lack of consistent definitions and nomenclature across clinical trials of novel devices, drugs, or biologics poses a significant barrier to accrual of knowledge in and across peripheral artery disease therapies and technologies. Recognizing this problem, the Peripheral Academic Research Consortium, together with the U.S. Food and Drug Administration and the Japanese Pharmaceuticals and Medical Devices Agency, has developed a series of pragmatic consensus definitions for patients being treated for peripheral artery disease affecting the lower extremities. These consensus definitions include the clinical presentation, anatomic depiction, interventional outcomes, surrogate imaging and physiological follow-up, and clinical outcomes of patients with lower-extremity peripheral artery disease. Consistent application of these definitions in clinical trials evaluating novel revascularization technologies should result in more efficient regulatory evaluation and best practice guidelines to inform clinical decisions in patients with lower extremity peripheral artery disease
Consensus standards for acquisition, measurement, and reporting of intravascular optical coherence tomography studies
Objectives: The purpose of this document is to make the output of the International Working Group for Intravascular Optical Coherence Tomography (IWG-IVOCT) Standardization and Validation available to medical and scientific communities, through a peer-reviewed publication, in the interest of improving the diagnosis and treatment of patients with atherosclerosis, including coronary artery disease. Background: Intravascular optical coherence tomography (IVOCT) is a catheter-based modality that acquires images at a resolution of ∼10 μm, enabling visualization of blood vessel wall microstructure in vivo at an unprecedented level of detail. IVOCT devices are now commercially available worldwide, there is an active user base, and the interest in using this technology is growing. Incorporation of IVOCT in research and daily clinical practice can be facilitated by the development of uniform terminology and consensus-based standards on use of the technology, interpretation of the images, and reporting of IVOCT results. Methods: The IWG-IVOCT, comprising more than 260 academic and industry members from Asia, Europe, and the United States, formed in 2008 and convened on the topic of IVOCT standardization through a series of 9 national and international meetings. Results: Knowledge and recommendations from this group on key areas within the IVOCT field were assembled to generate this consensus document, authored by the Writing Committee, composed of academicians who have participated in meetings and/or writing of the text. Conclusions: This document may be broadly used as a standard reference regarding the current state of the IVOCT imaging modality, intended for researchers and clinicians who use IVOCT and analyze IVOCT data
- …