41 research outputs found

    Successful radiation treatment of anaplastic thyroid carcinoma metastatic to the right cardiac atrium and ventricle in a pacemaker-dependent patient

    Get PDF
    Anaplastic thyroid carcinoma (ATC) is a rare, aggressive malignancy, which is known to metastasize to the heart. We report a case of a patient with ATC with metastatic involvement of the pacemaker leads within the right atrium and right ventricle. The patient survived external beam radiation treatment to his heart, with a radiographic response to treatment. Cardiac metastases are usually reported on autopsy; to our knowledge, this is the first report of the successful treatment of cardiac metastases encasing the leads of a pacemaker, and of cardiac metastases from ATCs, with a review of the pertinent literature

    Endocrinologic, neurologic, and visual morbidity after treatment for craniopharyngioma

    Get PDF
    Craniopharyngiomas are locally aggressive tumors which typically are focused in the sellar and suprasellar region near a number of critical neural and vascular structures mediating endocrinologic, behavioral, and visual functions. The present study aims to summarize and compare the published literature regarding morbidity resulting from treatment of craniopharyngioma. We performed a comprehensive search of the published English language literature to identify studies publishing outcome data of patients undergoing surgery for craniopharyngioma. Comparisons of the rates of endocrine, vascular, neurological, and visual complications were performed using Pearson’s chi-squared test, and covariates of interest were fitted into a multivariate logistic regression model. In our data set, 540 patients underwent surgical resection of their tumor. 138 patients received biopsy alone followed by some form of radiotherapy. Mean overall follow-up for all patients in these studies was 54 ± 1.8 months. The overall rate of new endocrinopathy for all patients undergoing surgical resection of their mass was 37% (95% CI = 33–41). Patients receiving GTR had over 2.5 times the rate of developing at least one endocrinopathy compared to patients receiving STR alone or STR + XRT (52 vs. 19 vs. 20%, χ2P < 0.00001). On multivariate analysis, GTR conferred a significant increase in the risk of endocrinopathy compared to STR + XRT (OR = 3.45, 95% CI = 2.05–5.81, P < 0.00001), after controlling for study size and the presence of significant hypothalamic involvement. There was a statistical trend towards worse visual outcomes in patients receiving XRT after STR compared to GTR or STR alone (GTR = 3.5% vs. STR 2.1% vs. STR + XRT 6.4%, P = 0.11). Given the difficulty in obtaining class 1 data regarding the treatment of this tumor, this study can serve as an estimate of expected outcomes for these patients, and guide decision making until these data are available

    ZAP-X Gyroscopic Radiosurgery System: A Preliminary Analysis of Clinical Applications within a Retrospective Case Series

    No full text
    INTRODUCTION: The ZAP-X Gyroscopic Radiosurgery system (ZAP Surgical Systems, Inc., San Carlos, CA, USA) is a novel high-dose targeted stereotactic radiosurgery platform for outpatient use that includes self-shielding, X-ray image guidance, and the capacity to aim the radiation beam gyroscopically at an intracranial lesion using 5 independent degrees of freedom. The ZAP-X Gyroscopic Radiosurgery system accomplishes these actions while meeting widely accepted standards for dose gradient and accuracy. This retrospective study examined data of patients treated with gyroscopic radiosurgery (GRS) to document clinical outcomes. METHODS: Medical records of all outpatients treated with GRS over a 20-month period from January 2019 to August 2020 were searched to extract relevant details, including follow-up data until August 2021 (32-month study interval). Patients with \u3c6 months of radiographical follow-up data were excluded unless death occurred. Data collection included pretreatment clinical history, pathological diagnosis, radiographical features, treatment parameters, and long-term clinical and radiographical follow-up. RESULTS: Sixty-eight patients received outpatient treatment with GRS during the 20-month treatment interval, with 59 patients remaining after exclusion for the minimum follow-up threshold, with a mean (standard deviation [SD]) fractionation of 1.85 (1.63). Eighty-two lesions were treated across a very heterogeneous patient population, including meningiomas (42.4%), metastases (39.0%), gliomas (6.8%), schwannomas (1.7%), and pituitary tumor (1.7%). Mean (SD) radiographical follow-up data (14.7 [6.60] months) were available for 56 patients. During that interval, 13 treated lesions in 13 patients (15.9%) demonstrated progression, 9 of which were stable during the initial posttreatment imaging surveillance period. Mean lesion volume was stable from pretreatment (2.54 cm3 [4.37 cm3]) to most recent follow-up (2.80 cm3 [8.20 cm3]) (t [79] = -0.310; p = 0.76). Minor adverse clinical events were noted in 3 (5.1%) of the 59 patients during the posttreatment phase that may have been related to the treatment. Ten (16.9%) patients died within the 32-month study interval. DISCUSSION/CONCLUSION: This preliminary assessment of the first series of patients treated with the Zap-X Gyroscopic Radiosurgery system documents its overall feasibility in clinical applications. Although the duration of follow-up was brief, GRS appeared to be both safe and effective. Additional analysis, with an ongoing prospective registry, is underway

    Relationship of glioblastoma multiforme to the subventricular zone is associated with survival

    No full text
    The subventricular zone (SVZ) lines the lateral ventricles and represents the origin of neural and some cancer stem cells. Tumors contacting the SVZ may be more invasive with higher potential to recruit migratory progenitor cells. Our specific aim was to determine whether SVZ involvement in glioblastoma multiforme (GBM) is associated with a higher recurrence rate and shorter overall survival. MR imaging and clinical data from 91 patients with GBM treated at our institution were retrospectively reviewed. Tumors were classified as type I if the contrast-enhancing lesion contacted both the SVZ and cortex on pre-operative MRI, type II if only the SVZ was involved, type III if only cortex was involved, and type IV if the lesion did not contact either the SVZ or cortex. Progression-free survival (PFS) and overall survival were estimated based on Kaplan-Meier calculations. When comparing type I tumors with types II-IV, only 39% of patients with type I tumors were free of recurrence and alive at 6 months, significantly fewer than for all other types combined (67%; P = .01). PFS at 6 months was also less, at only 47% among patients with SVZ-positive tumors, compared with 69% in the SVZ-negative group (P = .002). Patients with SVZ involvement also demonstrated a more rapid time to progression, compared with those not involving the SVZ (P = .003). Patients with GBM involving the SVZ have decreased overall survival and PFS, which may have prognostic and therapeutic implications

    Treatment planning system and beam data validation for the ZAP-X: A novel self-shielded stereotactic radiosurgery system

    No full text
    PURPOSE: To evaluate the treatment planning system (TPS) performance of the ZAP-X stereotactic radiosurgery (SRS) system through nondosimetric, dosimetric, and end-to-end (E2E) tests. METHODS: A comprehensive set of TPS commissioning and validation tests was developed using published guidelines. Nondosimetric validation tests included information transfer, computed tomography-magnetic resonance (CT-MR) image registration, structure/contouring, geometry, dose tools, and CT density. Dosimetric validation included comparisons between TPS and water tank/Solid Water measurements for various geometries and beam arrangements and end-to-end (E2E) tests. Patient-specific quality assurance was performed with an ion chamber in the Lucy phantom and with Gafchromic EBT3 film in the CyberKnife head phantom. RadCalc was used for independent verification of monitor units. Additional E2E tests were performed using the RPC Gamma Knife thermoluminescent dosimeter (TLD) phantom, MD Anderson SRS head phantom, and PseudoPatient gel phantom for independent absolute dose verification. RESULTS: CT-MR image registrations with known translational and rotational offsets were within tolerance (\u3c0.5 × maximum voxel dimension). Slice thickness and distance accuracy were within 0.1 mm, and volume accuracy was within 0 to 0.11 cm . Treatment planning system volume measurement uncertainty was within 0.1 to 0.4 cm . Ion chamber point-dose measurements for a single beam in a water phantom agreed to TPS-calculated values within ±4% for collimator diameters 10 to 25 mm, and ±6% for 7.5 mm, for all measured depths (7, 50, 100, 150, and 200 mm). In homogeneous Solid Water, point-dose measurements agreed to within ±4% for cones sizes 7.5 to 25 mm. With 1-cm high/low density inserts, measurements were within ±4.2% for cone sizes 10 to 25 mm. Film-based E2E using 4/5-mm cones resulted in a gamma passing rate (%GP) of 99.8% (2%/1.5 mm). Point-dose measurements in a Lucy phantom with an ion chamber using 36 beams distributed along three noncoplanar arcs agreed to within ±4% for cone sizes 10 to 25 mm. The RPC Gamma Knife TLD phantom yielded passing results with a measured-to-expected TLD dose ratio of 1.02. The MD Anderson SRS head phantom yielded passing results, with 4% TLD agreement and %GP of 95%/93% (5%/3 mm) for coronal/sagittal film planes. The RTsafe gel phantom gave %GP of \u3e95% (5%/2 mm) for all four targets. For our first 58 patients, film-based patient-specific quality assurance has resulted in an average %GP of 98.7% (range, 94-100%) at 2%/2 mm. CONCLUSIONS: Core ZAP-X features were found to be functional. On the basis of our results, point-dose and planar measurements were in agreement with TPS calculations using multiple phantoms and setup geometries, validating the ZAP-X TPS beam model for clinical use

    Meningiomas: knowledge base, treatment outcomes, and uncertainties. A RANO review.

    No full text
    Evolving interest in meningioma, the most common primary brain tumor, has refined contemporary management of these tumors. Problematic, however, is the paucity of prospective clinical trials that provide an evidence-based algorithm for managing meningioma. This review summarizes the published literature regarding the treatment of newly diagnosed and recurrent meningioma, with an emphasis on outcomes stratified by WHO tumor grade. Specifically, this review focuses on patient outcomes following treatment (either adjuvant or at recurrence) with surgery or radiation therapy inclusive of radiosurgery and fractionated radiation therapy. Phase II trials for patients with meningioma have recently completed accrual within the Radiation Therapy Oncology Group and the European Organisation for Research and Treatment of Cancer consortia, and Phase III studies are being developed. However, at present, there are no completed prospective, randomized trials assessing the role of either surgery or radiation therapy. Successful completion of future studies will require a multidisciplinary effort, dissemination of the current knowledge base, improved implementation of WHO grading criteria, standardization of response criteria and other outcome end points, and concerted efforts to address weaknesses in present treatment paradigms, particularly for patients with progressive or recurrent low-grade meningioma or with high-grade meningioma. In parallel efforts, Response Assessment in Neuro-Oncology (RANO) subcommittees are developing a paper on systemic therapies for meningioma and a separate article proposing standardized end point and response criteria for meningioma
    corecore