1,697 research outputs found

    Factors Associated With Receipt of Preventive Dental Treatment Procedures Among Adult Patients at a Dental Training School in Wisconsin, 2001-2002

    Get PDF
    Background: Gender differences in oral health-related quality of life and the fear of dental pain in seeking and receiving preventive dental care have been recognized and documented. Preventive dental treatment procedures (PDTPs) are commonly accepted as the primary approach to prevent dental disease. Objective: We examined whether the likelihood of receiving PDTPs differed by gender in adult patients receiving dental care at a dental training institution in Milwaukee, Wisconsin.Methods: Data from the Marquette University School of Dentistry electronic patient management database for 2001 through 2002 were analyzed. Descriptive, bivariate, and multivariable analyses were performed. The preventive procedures used in the study were those coded in accordance with the American Dental Association\u27s classification system: D1110 (adult prophylaxis: professional cleaning and polishing of the teeth), D1204 (adult topical application of fluoride), D1205 (adult topical application of fluoride plus prophylaxis), and D1330 (oral hygiene instruction).Results: Of the 1563 consecutive patient records (888 women, 675 men) reviewed for the years 2001-2002, 794 individuals (51%), aged 18 to 60 years, were identified as having received PDTPs. At the bivariate level, a significant gender difference in the receipt of PDTPs was identified (423 women [48%] vs 371 men [55%]; P = 0.004). In the multivariable analyses, age, race/ethnicity, marital status, poverty level, and health insurance type (public, private, none) were significantly associated with the receipt of PDTPs (all, P \u3c 0.05), but gender was not.Conclusions: Gender differences in receiving PDTPs were not found in this dental school patient population. Receipt of PDTPs was associated with other demographic factors such as age, race/ethnicity, marital status, income level, and health insurance

    Neglect of Medical Evidence of Torture in GuantĂĄnamo Bay: A Case Series

    Get PDF
    Vincent Iacopino and Stephen Xenakis review case records of nine individuals imprisoned at GuantĂĄnamo Bay which indicate that medical personnel assigned to the US Department of Defense neglected and/or concealed medical evidence of torture

    The Contribution of Plant Dioxygenases to Hypoxia Signaling

    Get PDF
    Dioxygenases catalyze the incorporation of one or two oxygen atoms into target organic substrates. Besides their metabolic role, these enzymes are involved in plant signaling pathways as this reaction is in several instances required for hormone metabolism, to control proteostasis and regulate chromatin accessibility. For these reasons, alteration of dioxygenase expression or activity can affect plant growth, development, and adaptation to abiotic and biotic stresses. Moreover, the requirement of co-substrates and co-factors, such as oxygen, 2-oxoglutarate, and iron (Fe2+), invests dioxygenases with a potential role as cellular sensors for these molecules. For example, inhibition of cysteine deoxygenation under hypoxia elicits adaptive responses to cope with oxygen shortage. However, biochemical and molecular evidence regarding the role of other dioxygenases under low oxygen stresses is still limited, and thus further investigation is needed to identify additional sensing roles for oxygen or other co-substrates and co-factors. Here, we summarize the main signaling roles of dioxygenases in plants and discuss how they control plant growth, development and metabolism, with a focus on the adaptive responses to low oxygen conditions

    Torture and its consequences: A challenge to clinical neuropsychology.

    Get PDF

    Mechanical Behavior and Failure Analysis of Prosthetic Retaining Screws after Long‐Term Use In Vivo. Part 2: Metallurgical and Microhardness Analysis

    Get PDF
    Abstract Purpose: This study involved testing and analyzing multiple retrieved prosthetic retaining screws after long‐term use in vivo to: (1) detect manufacturing defects that could affect in‐service behavior; (2) characterize the microstructure and alloy composition; and (3) further characterize the wear mechanism of the screw threads. Materials and Methods: Two new (control) screws from Nobel Biocare (NB) and 18 used (in service 18–120 months) retaining screws [12 from NB and 6 from Sterngold (SG)] were: (1) metallographically examined by light microscopy and scanning electron microscopy (SEM) to determine the microstructure; (2) analyzed by energy dispersive X‐ray (EDX) microanalysis to determine the qualitative and semiquantitative average alloy and individual phase compositions; and (3) tested for Vickers microhardness. Results: Examination of polished longitudinal sections of the screws using light microscopy revealed a significant defect in only one Group 4 screw. No significant defects in any other screws were observed. The defect was considered a “seam” originating as a “hot tear” during original casting solidification of the alloy. Additionally, the examination of longitudinal sections of the screws revealed a uniform homogeneous microstructure in some groups, while in other groups the sections exhibited rows of second phase particles. The screws for some groups demonstrated severe deformation of the lower threads and the bottom part of the screw leading to the formation of crevices and grooves. Some NB screws were comprised of Au‐based alloy with Pt, Cu, and Ag as alloy elements, while others (Groups 4 and 19) were Pd‐based with Ga, Cu, and Au alloy elements. The microstructure was homogeneous with fine or equiaxed grains for all groups except Group 4, which appeared inhomogeneous with anomalous grains. SG screws demonstrated a typical dendritic structure and were Au‐based alloy with Cu and Ag alloy elements. There were differences in the microhardness of gold alloy screws from NB and SG as well as palladium alloy screws from NB. Conclusions: Significant differences within NB retaining screws and between NB and SG screws were found for microstructure, major alloy constituents, and microhardness

    Mechanical Behavior and Failure Analysis of Prosthetic Retaining Screws after Long‐term Use in vivo. Part 4: Failure Analysis of 10 Fractured Retaining Screws Retrieved from Three Patients

    Get PDF
    Purpose: The aim of this study was to perform a failure analysis on fractured prosthetic retaining screws after long‐term use in vivo. Additionally, the study addresses the commonly asked question regarding whether complex repeated functional occlusal forces initiate fatigue‐type cracks in prosthetic retaining screws. Materials and Methods: Ten fractured prosthetic retaining screws retrieved from three patients treated with fixed detachable hybrid prostheses were subjected to a failure analysis. In patients 1 and 2, the middle three retaining screws of the prostheses were found fractured at retrieval time after they had been in service for 20 and 19 months, respectively. In patient 3, the middle three and one of the posterior retaining screws were found to be fractured at retrieval after they had been in service for 18 months. Low power stereomicroscopy and high‐power scanning electron microscopy (SEM) were performed to analyze the fractured surfaces of the retaining screws examining fatigue cracks in greater detail. Results: Typical fatigue failure characterized by ratchet mark formation was revealed by light microscopy and SEM for all examined screws. Using low magnification light microscopy, ratchet marks were visible on the fracture surfaces of only two screws. SEM examination revealed all three classical stages of fatigue failure, and it was possible to see the ratchet marks on the fracture surfaces of all specimens, indicating a fatigue zone. The final catastrophic overload fracture appeared fibrous, indicating ductile fracture. The final overload ductile fracture surfaces showed equiaxed dimples, suggesting tensile overload in all examined screws except in two specimens that showed an elongated dimple pattern indicating shear/tearing overload forces. Conclusions: Fracture of prosthetic retaining screws in hybrid prostheses occurs mainly through a typical fatigue mode involving mostly the middle anterior three screws. Fatigue cracks can grow in more than one prosthetic retaining screw, leading to fracture before the patient or clinician determines that any problem exists

    Mechanical Behavior and Failure Analysis of Prosthetic Retaining Screws after Long‐term Use In Vivo. Part 3: Preload and Tensile Fracture Load Testing

    Get PDF
    Purpose: The aim of this study was to determine the preload and tensile fracture load values of prosthetic retaining screws after long‐term use in vivo compared to unused screws (controls). Additionally, the investigation addressed whether the preload and fracture load values of prosthetic retaining screws reported by the manufacturer become altered after long‐term use in vivo. Materials and Methods: For preload testing, 10 new screws (controls) from Nobel Biocare (NB) and 73 used retaining screws [58 from NB and 15 from Sterngold (SG)] were subjected to preload testing. For tensile testing, eight controls from NB and 58 used retaining screws (46 from NB and 12 from SG) were subjected to tensile testing. Used screws for both tests were in service for 18–120 months. A custom load frame, load cell, and torque wrench setup were used for preload testing. All 83 prosthetic screws were torqued once to 10 Ncm, and the produced preload value was recorded (N) using an X–Y plotter. Tensile testing was performed on a universal testing machine and the resulting tensile fracture load value was recorded (N). Preload and tensile fracture load values were analyzed with 2‐way ANOVA and Tukey post‐hoc tests. Results: There was a significant difference between preload values for screws from NB and screws from SG (p \u3c 0.001). The preload values for gold alloy screws from NB decreased as the number of years in service increased. There was a significant difference between tensile fracture values for the three groups (gold alloy screws from NB and SG and palladium alloy screws from NB) at p \u3c 0.001. The tensile fracture values for gold alloy screws from NB and SG decreased as the number of years in service increased. Conclusions: In fixed detachable hybrid prostheses, perhaps as a result of galling, the intended preload values of prosthetic retaining screws may decrease with increased in‐service time. The reduction of the fracture load value may be related to the increase of in‐service time; however, the actual determination of this relationship is not possible from this study alone

    Exploring the multiple effects of the invasive alien robinia tree: a PhD project presentation

    Get PDF
    The poster explains the background, research questions and objectives and methods of the PhD study on black locust (Robinia pseudoacacia) funded by the Linda Scattolin J:ROBIN project (2016-2019)

    Ruptured middle cerebral artery aneurysms. retrospective study and multivariate analysis of 105 patients treated by surgical clipping

    Get PDF
    Objective of the study: We analyze in this study only patients with surgically treated ruptured aneurysms in order to identify statistical significance of each predictive factor in terms of outcome of patients with ruptured MCAAs. Materials and methods: In this retrospective study, we analyzed 105 cases of ruptured MCAAs, admitted from January 2001 to December 2015 at Neurosurgical Department of Umberto I University Hospital of Rome, Italy. Predictive factors evaluated are: Patient’s features (age, sex, co-morbidities), aneurysmal location (proximal, bifurcation or distal) and size of aneurysmal dome (small, large or giant); surgical timing (ultra-early, early, delayed), and Intracerebral Hemorrhage (ICH) volume. For each parameter we calculated mean and standard deviation, covariance and relation coefficient (through the linear regression model). Results: The clinical evaluation of patients assessed through the World Federation of Neurological Surgeons (WFSN) grading scale, that is 5 for 37 patients (35.3%), 4 for 28 patients. In 40% of cases the maximum sac diameter was between 7 mm and 12 mm, while in 67% of the cases the aneurysms concerned the bifurcation of the middle cerebral artery. ICH was associated in 57 cases (54.3%). As far as outcome is concerned, at 3 months, 32 patients (30.47%) had a favourable outcome, while 73 (69.52%) patients had not favourable outcome. To one year, 46 patients (43.8%) had favourable outcomes, while 59 patients (56.19%) had not favourable outcome. The mean outcomes as mean mRS are significantly less favourable in patients with ICH. Conclusion: In MCAAs patients, the presence of ICH strongly affects the outcome with a marked increase in mortality and morbidity. Surgical timing significantly influences the outcomes and ultra-early surgery should always be taken into account

    Mechanical Behavior and Failure Analysis of Prosthetic Retaining Screws after Long‐term Use In Vivo. Part 1: Characterization of Adhesive Wear and Structure of Retaining Screws

    Get PDF
    Purpose: The general aim of this study and those presented in Parts 2–4 of this series was to characterize the structure, properties, wear, and fracture of prosthetic retaining screws in fixed detachable hybrid prostheses after long‐term use in vivo. This part of the overall investigation addresses whether there are differences in thread wear between the screws closest to the fulcrum and those that are farthest from the fulcrum in fixed detachable hybrid prostheses. Materials and Methods: The total number of prosthetic retaining screws used in this study was 100 (10 new and 90 used). New screws (controls) from Nobel Biocare (NB) were divided into Group 1 (slotted) and Group 2 (hexed). Ninety used screws (in service 18–120 months) were retrieved from fixed detachable hybrid prostheses in 18 patients (5 screws from each patient, 60 from NB and 30 from Sterngold). The used screws were divided into 18 groups. Additionally, each group was subdivided into A and B categories. Category A contained the middle three prosthetic screws, which were considered the farthest screws from the fulcrum line. Category B contained the most posterior two screws, which were considered the screws closest to the fulcrum line. All 100 screws were subjected to thorough, nondestructive testing. Results: Light and scanning electron microscopic examination of all used screws for each group revealed surface deterioration of the active profile of the screw threads consistent with adhesive wear. The observed thread profile deterioration ranged from mild to severe. The wear was aggressive enough to cause galling, which led to thinning of the threads and, in severe cases, to knife‐edges at thread crests. In ten groups, the most anterior three screws exhibited more wear than the most posterior two screws. In addition to thread wear, severe plastic deformation was detected on the bottom part of each screw for three groups, and a long external longitudinal crack was detected in one screw of Group 2. Conclusions: The findings of this study and those presented in Parts 2–4 demonstrate that different retaining screws from the same manufacturer and/or from different manufacturers have different geometrical design, microstructures, major alloy constituents, and microhardness, and that these differences influence their preload and fractured load values. In this part of the overall investigation, the occurrence of galling as a result of wear involving prosthetic retaining screws appears to be an inevitable and unavoidable consequence of long‐term use in vivo in fixed detachable hybrid prostheses regardless of the intended/original preload value. The galling rate is greater on the middle three screws compared to the most posterior two screws in fixed detachable hybrid prostheses. The wear pattern is consistent with an adhesive wear mechanism; however, this study does not provide enough data to support a definitive analysis
    • 