302 research outputs found

    Embriogenesi e malformazioni dell’apparato urinario e genitale maschile

    Get PDF
    Non previsto perché trattasi di capitolo di libr

    I tumori del rene

    Get PDF
    non presente (capitolo di libro

    Quality and antioxidant traits of organic apricots (Prunus armeniaca L.) at harvest and after storage

    Get PDF
    In recent years, consumers are interested in low-input agricultural practices and healthy foods. The aim of this research was to assess the pomological quality and antioxidant properties of organic apricot fruits from several cultivars which have been previously evaluated under integrated cultivation. Apricot quality after cold storage (14 days at 4±0.5°C, 90% relative humidity) was also tested in order to evaluate the fruit storability. Fruits from seven Italian apricot cultivars (Prunus armeniaca L.), grown under organic management system, were analyzed according to the main physicochemical traits, total antioxidant activity (TAC) and total phenols content (TP). Organic practices did not always have a significant influence on the major fruit quality attributes. Three out of seven genotypes positively responded to organic management showing, in particular, higher TAC and TP levels than integrated apricot fruits. Moreover, the capacity to keep unchanged the physicochemical and antioxidant properties of fruits after storage was an interesting result considering the high susceptibility of fresh apricots to conservation. The maintenance of high quality parameters could be an added-value for organic apricot productions. In conclusion, this study provides new perspectives for organically grown apricots, confirming the importance of the cultivar’s choice in order to obtain the best quality performances, in agreement to researches establishing as the genotype may influence more than any other parameters the fruit quality characteristics

    miR-21-mediated regulation of 15-hydroxyprostaglandin dehydrogenase in colon cancer

    Get PDF
    This work is licensed under a Creative Commons Attribution 4.0 International License.Elevated prostaglandin E2 (PGE2) levels are observed in colorectal cancer (CRC) patients, and this increase is associated with poor prognosis. Increased synthesis of PGE2 in CRC has been shown to occur through COX-2-dependent mechanisms; however, loss of the PGE2-catabolizing enzyme, 15-hydroxyprostaglandin dehydrogenase (15-PGDH, HPGD), in colonic tumors contributes to increased prostaglandin levels and poor patient survival. While loss of 15-PGDH can occur through transcriptional mechanisms, we demonstrate that 15-PGDH can be additionally regulated by a miRNA-mediated mechanism. We show that 15-PGDH and miR-21 are inversely correlated in CRC patients, with increased miR-21 levels associating with low 15-PGDH expression. 15-PGDH can be directly regulated by miR-21 through distinct sites in its 3′ untranslated region (3′UTR), and miR-21 expression in CRC cells attenuates 15-PGDH and promotes increased PGE2 levels. Additionally, epithelial growth factor (EGF) signaling suppresses 15-PGDH expression while simultaneously enhancing miR-21 levels. miR-21 inhibition represses CRC cell proliferation, which is enhanced with EGF receptor (EGFR) inhibition. These findings present a novel regulatory mechanism of 15-PGDH by miR-21, and how dysregulated expression of miR-21 may contribute to loss of 15-PGDH expression and promote CRC progression via increased accumulation of PGE2.NIH R01 CA134609NIH R01 AR069044NIH/NCI Cancer Center Support Grant (P30 CA168524)New Jersey Commission on Cancer ResearchAmerican Heart Association (15GRNT23240019

    Loop colostomies are safe in anorectal malformations

    Get PDF
    Aim of the study: Divided colostomy (DC) has been recommended in anorectal malformations (ARMs) with previously reported advantages of decreasing overflow into the distal limb and urinary tract infections (UTIs). Skin bridge loop colostomy (LC) is a technically easier alternative without an increase in these complications. We report our institutional experience of LC in ARM. Methods: Retrospective study (Institution-approved Clinical Audit) reviewing the clinical records of all patients with ARM undergoing stoma formation in a single UK tertiary pediatric surgical center (2000–2015). Data collected included type of ARM, associated anomalies, type and level of colostomy, time to stoma closure, complications and UTIs. Results: One hundred and eighty-two (95 female) patients underwent colostomy formation for ARM. The vast majority (171/ 94%) underwent LC; 9 (5%) had a divided colostomy (DC) and 2 (1%) had no available data. The spectrum of defects in girls included rectovestibular (62/65%), rectovaginal (4/4%) and cloaca (29/31%). In boys, 71 (82%) had a fistula to the urinary tract and 16 (18%) presented with a perineal fistula. Urological abnormalities coexisted in 87 (47.8%) patients. Thirty five (21%) patients developed UTIs. Among the 19 girls who developed UTI, 8 had rectovestibular fistula and 11 had cloaca. Of the 16 boys who developed UTI, 14 had a fistula to the urinary tract and 11 had an independent urological abnormality. The mean time from stoma formation to stoma closure was 10 (3–52) months. Complications were reported in 22 (12%) LCs. Fifteen patients (9%) developed a stoma prolapse following LC with 10 (6%) requiring surgical revision. Conclusions: This is the largest reported series of outcomes following LC for ARM. LC is easier to perform and to close, requiring minimal surgical access, with comparable complications and outcomes to those published for DC. Type of study: Retrospective comparative study. Level of evidence: III

    Independent validation of sepsis index for sepsis screening in the emergency department

    Get PDF
    (1) Background: The early detection of sepsis is still challenging, and there is an urgent need for biomarkers that could identify patients at a high risk of developing it. We recently developed an index, namely the Sepsis Index (SI), based on the combination of two CBC parameters: monocyte distribution width (MDW) and mean monocyte volume (MMV). In this study, we sought to independently validate the performance of SI as a tool for the early detection of patients at a high risk of sepsis in the Emergency Department (ED). (2) Methods: We enrolled all consecutive patients attending the ED with a request of the CBC. MDW and MMV were measured on samples collected in K3-EDTA tubes on the UniCel DxH 900 haematology analyser. SI was calculated based on the MDW and MMV. (3) Results: We enrolled a total of 703 patients stratified into four subgroups according to the Sepsis-2 criteria: control (498), infection (105), SIRS (52) and sepsis (48). The sepsis subgroup displayed the highest MDW (median 27.5, IQR 24.6–32.9) and SI (median 1.15, IQR 1.05–1.29) values. The ROC curve analysis for the prediction of sepsis showed a good and comparable diagnostic accuracy of the MDW and SI. However, the SI displayed an increased specificity, positive predictive value and positive likelihood ratio in comparison to MDW alone. (4) Conclusions: SI improves the diagnostic accuracy of MDW for sepsis screening

    Chemotherapy cardiotoxicity: cardioprotective drugs and early identification of cardiac dysfunction.

    Get PDF
    Background: Chemotherapy cardiotoxicity is an emerging problem and it is very important to prevent cardiac dysfunction caused by anticancer drugs. The aim of this study was to assess the alterations of the cardiac function induced by chemotherapy in a follow-up of 2 years and to evaluate the cardioprotective role of angiotensin-converting enzyme inhibitors (ACEIs) in the prevention of cardiac dysfunction. Methods: A prospective study was carried out using patients with breast cancer (85 women; median age 57W12years) and other inclusion and exclusion criteria. On the basis of treatment, patients were divided into six groups: fluorouracil-epirubicincyclophosphamide, FEC (group A); FEC and trastuzumab (B); trastuzumab (C); FEC and taxotere (D); FEC, paclitaxel and trastuzumab (E); and chemotherapy and cardioprotective drugs (F). Cardiological evaluation including electrocardiogram and conventional echocardiogram with tissue Doppler imaging (TDI) was carried out at T0 (before starting chemotherapy), T1 (after 6months from the start of chemotherapy) and T2 (2 years after the end of chemotherapy). Results: Significant changes in the TDI parameters of systolic and diastolic function were observed at T1 and T2 in all patients. A significant reduction of left ventricular ejection fraction (LVEF) was observed only at T2. In the patients treated with ACEI (F), these changes were less significant than in other groups and they do not have significant changes in the indices of diastolic function. Conclusion: TDI is more sensitive than conventional echocardiogram in the early diagnosis of cardiac dysfunction and ACEIs seem to have an important role in the prevention of cardiotoxicity

    Role of interface region on the optoelectronic properties of silicon nanocrystals embedded in SiO2

    Get PDF
    Light emitting silicon nanocrystals embedded in SiO2 have been investigated by x-ray absorption measurements in total electron and photoluminescence yields, by energy filtered TEM analysis and by ab-initio total energy calculations. Both experimental and theoretical results show that the interface between the silicon nanocrystals and the surrounding SiO2 is not sharp: an intermediate region of amorphous nature and of variable composition links the crystalline Si with the amorphous stoichiometric SiO2. This region plays an active role in the light emission process

    A new tool for sepsis screening in the Emergency Department

    Get PDF
    In this study, we developed and evaluated the diagnostic accuracy of the Sepsis Index for early sepsis screening in the Emergency Department (ED). Sepsis Index is based on the combination of monocyte distribution width (MDW) and mean monocyte volume (MMV). Sepsis Index≥1 was selected to define sepsis. We tested its diagnostic accuracy in an ED population stratified in four groups: Controls, Systemic Inflammatory Response Syndrome (SIRS), infection, and sepsis, according to Sepsis-2 criteria. Patients with sepsis displayed higher median Sepsis Index value than patients without sepsis. At the receiver operating characterictis (ROC) curve analysis for the prediction of sepsis, the area under the curve (AUC) of MDW and Sepsis Index were similar: 0.966 (95%CI 0.947-0.984), and 0.964 (95%CI 0.942-0.985), respectively. Sepsis Index showed increased specificity than MDW (94.7 vs. 90.6%), without any decrease in sensitivity (92.0%). Additionally, LR+ increased from 9.8 (MDW) to 17.4 (Sepsis Index), without any substantial change in LR-(respectively 0.09 vs. 0.08). Finally, PPV increased from 0.286 (MDW) to 0.420 (Sepsis Index). Sepsis Index improves the diagnostic accuracy of MDW alone for sepsis screening
    • …
    corecore