3 research outputs found

    RP-LC and HPTLC Methods for the Determination of Olmesartan Medoxomil and Hydrochlorothiazide in Combined Tablet Dosage Forms

    Get PDF
    Two new, rapid, precise, accurate and specific chromatographic methods were described for the simultaneous determination of olmesartan medoxomil and hydrochlorothiazide in combined tablet dosage forms. The first method was based on reversed phase liquid chromatography using an Eurosphere 100 RP C18 column (250 × 4.6 mm ID, 5 μm). The mobile phase was methanol–0.05% o-phosphoric acid (60:40 v/v) at a flow rate of 1.0 mL min−1. Commercially available tablets and laboratory mixtures containing both drugs were assayed and detected using a UV detector at 270 nm. The second method involved silica gel 60 F254 high performance thin layer chromatography and densitometric detection at 254 nm using acetonitrile–ethyl acetate–glacial acid (7:3:0.4 v/v/v) as the mobile phase. Calibration curves ranged between 200–600 and 125–375 ng spot−1 for olmesartan and hydrochlorothiazide, respectively

    Simultaneous determination of benazepril hydrochloride and hydrochlorothiazide in tablets by second-order derivative spectrophotometry

    No full text
    A second-order derivative spectrophotometric method for the simultaneous determination of benazepril hydrochloride and hydrochlorothiazide in pharmaceutical dosage forms is described. The determination of benazepril hydrochloride in the presence of hydrochlorothiazide was achieved by measuring the second-order derivative signals at 253.6 and 282.6 nm, while the second-order derivative signal at 282.6 nm was measured for the determination of hydrochlorothiazide. The linear dynamic ranges were 14.80-33.80 mu g ml(-1) for benazepril hydrochloride and 18.50-42.20 mu g ml(-1) for hydrochlorothiazide, the correlation coefficient for the calibration graphs were better than 0.9998, n = 5, the precision (%RSD) was better than 1.43% and the accuracy was satisfactory (E-r < 0.99%). The detection limits were found to be 2.46 and 1.57 mu g ml(-1) for benazepril hydrochloride and hydrochlorothiazide, respectively. The method was applied in the quality control of commercial tablets and proved to be suitable for rapid and reliable quality control. (C) 1999 Elsevier Science B.V. All rights reserved

    Simultaneous determination of benazepril hydrochloride and hydrochlorothiazide by micro-bore liquid chromatography

    No full text
    A micro-bore liquid chromatographic method was developed for the simultaneous determination of benazepril hydrochloride and hydrochlorothiazide in pharmaceutical dosage forms. The use of a BDS C-18 micro-bore analytical column, results in substantial reduction in solvent consumption and increased sensitivity. The mobile phase consisted of a mixture of 0.025 M sodium dihydrogen phosphate (pH 4.8) and acetonitrile (55:45, v/v), pumped at a flow rate of 0.40 ml min(-1). Detection was set at 250 nm using an ultraviolet detector. Calibration graphs are linear (r better than 0.9991, n = 5), in concentration range 5.0-20.0 mu g ml(-1) for benazepril hydrochloride and 6.2-25.0 mu g ml(-1) for hydrochlorothiazide. The intra- and interday R.S.D. values were < 1.25% (n = 5), while the relative percentage error (E-r) was < 0.9% (n = 5). The detection limits attained according to IUPAC definition were 0.88 and 0.58 mu g ml(-1) for benazepril hydrochloride and hydrochlorothiazide, : respectively. The method was applied in the quality control of commercial tablets and content uniformity test and proved to be suitable for rapid and reliable quality control. (C) 1999 Elsevier Science B.V. All rights reserved
    corecore