176 research outputs found
MicroRNA expression profiles in pediatric dysembryoplastic neuroepithelial tumors.
© Springer Science+Business Media New York 2015Among noncoding RNAs, microRNAs (miRNAs) have been most extensively studied, and their biology has repeatedly been proven critical for central nervous system pathological conditions. The diagnostic value of several miRNAs was appraised in pediatric dysembryoplastic neuroepithelial tumors (DNETs) using miRNA microarrays and receiving operating characteristic curves analyses. Overall, five pediatric DNETs were studied. As controls, 17 samples were used: the FirstChoice Human Brain Reference RNA and 16 samples from deceased children who underwent autopsy and were not present with any brain malignancy. The miRNA extraction was carried out using the mirVANA miRNA Isolation Kit, while the experimental approach included miRNA microarrays covering 1211 miRNAs. Quantitative real-time polymerase chain reaction was performed to validate the expression profiles of miR-1909* and miR-3138 in all samples initially screened with miRNA microarrays. Our findings indicated that miR-3138 might act as a tumor suppressor gene when down-regulated and miR-1909* as a putative oncogenic molecule when up-regulated in pediatric DNETs compared to the control cohort. Subsequently, both miRNA signatures might serve as putative diagnostic biomarkers for pediatric DNETs.Peer reviewedFinal Accepted Versio
Detection Optimization of Disbond in Layered Composites with Varying Thicknesses using an Open-Ended Rectangular Waveguide
The detection of air disbond in layered dielectric composite, which is an important practical issue in many industries, is studied both theoretically and experimentally. Sensitivity of disbond detection depends on certain parameters, like the frequency of operation, the distance between the sensor and the first dielectric layer, and the layered composite geometry (conductor backed or terminated by an infinite half-space of air). The impact of all these parameters is investigated theoretically and then verified experimentally
DNA METHYLATION ANALYSIS OF PAEDIATRIC LOW-GRADE ASTROCYTOMAS IDENTIFIES A TUMOUR-SPECIFIC SIGNATURE AT A SET OF ENHANCERS
Calibration and Measurement of Dielectric Properties of Finite Thickness Composite Sheets with Open-Ended Coaxial Sensors
The application of open-ended coaxial sensors for dielectric measurement of finite thickness composite sheets is studied. Expressions for calculation of the complex aperture admittance for two geometries are presented. These expressions are used to calculate the dielectric constant of infinite half-space as well as finite thickness slabs. A more efficient method of such calculations, using a personal computer, for low to medium loss dielectrics is demonstrated. The question of when a dielectric layer may be considered as infinitely thick is also addressed, and examples are presented. A different calibration technique (compared to the conventional ones) is described and successfully implemented. This calibration technique utilizes a dielectric sheet with known dielectric properties and thickness. Measurements for different airgaps between the open-ended coaxial line and the dielectric sheet are used to perform and enhance the calibration. The results of this calibration technique and several subsequent measurements are presented and discussed
Microwave Noncontact Examination of Disbond and Thickness Variation in Stratified Composite Media
Numerical and experimental results of a microwave noncontact, nondestructive detection and evaluation of disbonds and thickness variations in stratified composite media are presented. The aperture admittance characteristics of a flange mounted rectangular waveguide radiating into a layered, generally lossy dielectric media backed or unbacked by a conducting sheet is modeled. The theoretical implementation is based on a Fourier transform boundary matching technique to construct the field components in each medium, coupled with a stationary form of the terminating aperture admittance of the waveguide. The model can serve as a reliable test bed for real-time examination of layered composite media. Experimental results for several cases are presented which show good agreement with the theoretical findings. This is a versatile technique for near-field in situ interrogation of stratified composite media which provides for high resolution measurements
Microwave Detection Optimization of Disbond in Layered Dielectrics with Varying Thickness
The detection sensitivity optimization of air disbond in layered dielectric composites, using an open-ended rectangular waveguide, is studied both theoretically and experimentally. The sensitivity of the disbond detection is strongly influenced by the proper choice of parameters such as the operating frequency and the layered composite geometry (conductor backed or terminated by an infinite half-space of air). The capability of optimizing the measurement system parameters to detect and estimate the thickness of a disbonded layer independent of some changes in the thickness of the dielectric coating is also demonstrated. The impact of the parameters influencing detection optimization is theoretically investigated and then experimentally verified
Anti-cancer effects and mechanism of actions of aspirin analogues in the treatment of glioma cancer
INTRODUCTION: In the past 25 years only modest advancements in glioma treatment have been made, with patient prognosis and median survival time following diagnosis only increasing from 3 to 7 months. A substantial body of clinical and preclinical evidence has suggested a role for aspirin in the treatment of cancer with multiple mechanisms of action proposed including COX 2 inhibition, down regulation of EGFR expression, and NF-κB signaling affecting Bcl-2 expression. However, with serious side effects such as stroke and gastrointestinal bleeding, aspirin analogues with improved potency and side effect profiles are being developed. METHOD: Effects on cell viability following 24 hr incubation of four aspirin derivatives (PN508, 517, 526 and 529) were compared to cisplatin, aspirin and di-aspirin in four glioma cell lines (U87 MG, SVG P12, GOS – 3, and 1321N1), using the PrestoBlue assay, establishing IC50 and examining the time course of drug effects. RESULTS: All compounds were found to decrease cell viability in a concentration and time dependant manner. Significantly, the analogue PN517 (IC50 2mM) showed approximately a twofold increase in potency when compared to aspirin (3.7mM) and cisplatin (4.3mM) in U87 cells, with similar increased potency in SVG P12 cells. Other analogues demonstrated similar potency to aspirin and cisplatin. CONCLUSION: These results support the further development and characterization of novel NSAID derivatives for the treatment of glioma
Microwave Diagnosis of Rubber Compounds
The results of a study investigating the dielectric properties of rubber compounds and their constituents in the frequency range of 5 to 24 GHz are presented. A completely filled short circuited waveguide technique was used to conduct these dielectric measurements. The influence of carbon black content in rubber was investigated for carefully prepared rubber samples. The results showed that for all frequencies, the dielectric constant increases as a function of increasing carbon black content. The variation of dielectric constant values decreases as frequency increases. The presence of curatives in uncured rubber samples was also detected, which indicates the sensitivity of microwaves to the chemical reaction triggered by curatives
A Proposal for Future Modifications on Clinical TNM Staging System of Retinoblastoma Based on the American Joint Committee on Cancer Staging Manual, 7 th and 8 th Editions
Real-Time and On-Line Near-Field Microwave Inspection of Surface Defects in Rolled Steel
The potential and limitations of near-field microwave inspection techniques for detecting various surface defects in rolled steel have been investigated. The focus of this study has been to investigate this potential for tin mill products containing gross and subtle defects including steel induced defects, roll marks, holes, scratches and gouges
- …
