33 research outputs found
Removal of power-line interference from the ECG: a review of the subtraction procedure
BACKGROUND: Modern biomedical amplifiers have a very high common mode rejection ratio. Nevertheless, recordings are often contaminated by residual power-line interference. Traditional analogue and digital filters are known to suppress ECG components near to the power-line frequency. Different types of digital notch filters are widely used despite their inherent contradiction: tolerable signal distortion needs a narrow frequency band, which leads to ineffective filtering in cases of larger frequency deviation of the interference. Adaptive filtering introduces unacceptable transient response time, especially after steep and large QRS complexes. Other available techniques such as Fourier transform do not work in real time. The subtraction procedure is found to cope better with this problem. METHOD: The subtraction procedure was developed some two decades ago, and almost totally eliminates power-line interference from the ECG signal. This procedure does not affect the signal frequency components around the interfering frequency. Digital filtering is applied on linear segments of the signal to remove the interference components. These interference components are stored and further subtracted from the signal wherever non-linear segments are encountered. RESULTS: Modifications of the subtraction procedure have been used in thousands of ECG instruments and computer-aided systems. Other work has extended this procedure to almost all possible cases of sampling rate and interference frequency variation. Improved structure of the on-line procedure has worked successfully regardless of the multiplicity between the sampling rate and the interference frequency. Such flexibility is due to the use of specific filter modules. CONCLUSION: The subtraction procedure has largely proved advantageous over other methods for power-line interference cancellation in ECG signals
Ventricular beat detection in single channel electrocardiograms
BACKGROUND: Detection of QRS complexes and other types of ventricular beats is a basic component of ECG analysis. Many algorithms have been proposed and used because of the waves' shape diversity. Detection in a single channel ECG is important for several applications, such as in defibrillators and specialized monitors. METHODS: The developed heuristic algorithm for ventricular beat detection includes two main criteria. The first of them is based on steep edges and sharp peaks evaluation and classifies normal QRS complexes in real time. The second criterion identifies ectopic beats by occurrence of biphasic wave. It is modified to work with a delay of one RR interval in case of long RR intervals. Other algorithm branches classify already detected QRS complexes as ectopic beats if a set of wave parameters is encountered or the ratio of latest two RR intervals RR(i-1)/RR(i )is less than 1:2.5. RESULTS: The algorithm was tested with the AHA and MIT-BIH databases. A sensitivity of 99.04% and a specificity of 99.62% were obtained in detection of 542014 beats. CONCLUSION: The algorithm copes successfully with different complicated cases of single channel ventricular beat detection. It is aimed to simulate to some extent the experience of the cardiologist, rather than to rely on mathematical approaches adopted from the theory of signal analysis. The algorithm is open to improvement, especially in the part concerning the discrimination between normal QRS complexes and ectopic beats
Public access defibrillation: Suppression of 16.7 Hz interference generated by the power supply of the railway systems
BACKGROUND: A specific problem using the public access defibrillators (PADs) arises at the railway stations. Some countries as Germany, Austria, Switzerland, Norway and Sweden are using AC railroad net power-supply system with rated 16.7 Hz frequency modulated from 15.69 Hz to 17.36 Hz. The power supply frequency contaminates the electrocardiogram (ECG). It is difficult to be suppressed or eliminated due to the fact that it considerably overlaps the frequency spectra of the ECG. The interference impedes the automated decision of the PADs whether a patient should be (or should not be) shocked. The aim of this study is the suppression of the 16.7 Hz interference generated by the power supply of the railway systems. METHODS: Software solution using adaptive filtering method was proposed for 16.7 Hz interference suppression. The optimal performance of the filter is achieved, embedding a reference channel in the PADs to record the interference. The method was tested with ECGs from AHA database. RESULTS: The method was tested with patients of normal sinus rhythms, symptoms of tachycardia and ventricular fibrillation. Simulated interference with frequency modulation from 15.69 Hz to 17.36 Hz changing at a rate of 2% per second was added to the ECGs, and then processed by the suggested adaptive filtering. The method totally suppresses the noise with no visible distortions of the original signals. CONCLUSION: The proposed adaptive filter for noise suppression generated by the power supply of the railway systems has a simple structure requiring a low level of computational resources, but a good reference signal as well
Biphasic pulses enhance bleomycin efficacy in a spontaneous canine genital tumor model of chemoresistance: Sticker sarcoma
Sticker's sarcoma (also known as transmissible venereal tumor) is a horizontally transmitted neoplasm of the dog, that is passed with coitus. It is a locally aggressive tumor with a low tendency to metastatic spread. The most common locations are the genitals, the nose, the perianal area. Standard treatment consists with chemotherapy with vincristine, however other therapies such as, cryotherapy, immunotherapy or, in selected cases, radiation therapy, have been reported. In this article we describe the outcome of a small cohort of canine patients, with chemotherapy resistant transmissible venereal tumor (TVT), treated with bleomycin selectively driven by trains of biphasic pulses (electrochemotherapy). Three canine patients, with refractory TVT, entered the study and received two sessions of ECT under sedation. The pets had local injection of bleomycin at the concentration of 1.5 mg/ml and five minutes after the chemotherapy, trains of 8 biphasic electric pulses lasting 50 + 50 ÎĽs each, with 1 ms interpulse intervals, were delivered by means of modified caliper or, for difficult districts, through paired needle electrode. All the patients responded to the treatment and are still in remission at different times. Electrochemotherapy appears as a safe and efficacious modality for the treatment of TVT and warrants further investigations
Evaluation of Cisplatin as an Electrochemotherapy Agent for the Treatment of Incompletely Excised Mast Cell Tumors in Dogs
Background: Electrochemotherapy (ECT) couples the administration of anticancer drugs with the delivery of electric pulses that increase the drug uptake through the cell membranes, resulting in an improved efficacy. Hypothesis: To evaluate the tolerability and efficacy of cisplatin (CDDP) as an ECT agent to prevent recurrence of incompletely resected mast cell tumors (MCTs). Animals: Thirty-seven dogs. Methods: Prospective study recruiting dogs with incompletely excised MCTs as confirmed by surgeon and pathology reports. After debulking, the tumor bed and margins were infiltrated with CDDP, and then exposed to trains of biphasic electrical pulses under sedation. Five minutes after the injection of the chemotherapy agent, sequences of 8 biphasic pulses lasting 50 + 50μs each, were delivered in bursts of 1,300V/cm for sclerosed and of 800V/cm for exposed lesions, with caliper or needle array electrodes, respectively. A second session was performed 1 or 2 weeks later based on clinical considerations. Results: The treatment was well tolerated with minimal adverse effects. Twenty-nine dogs had no evidence of recurrence over the 6-year study period, 6 had tumor recurrence, 1 died of multiple cutaneous MCTs, and 1 died of unrelated causes. The estimated median time to recurrence was 1,200 days. Recurrence was not observed among the long-term (>1 year) treated dogs. Conclusions and Clinical Importance: ECT with CDDP appears effective in the treatment of incompletely resected MCT in dogs and could be a useful addition to the current options based on its low cost, limited toxicity, and ease of administration. © 2011 by the American College of Veterinary Internal Medicine
Biphasic pulses enhance bleomycin efficacy in a spontaneous canine perianal tumors model
Perianal tumors (adenoma and carcinoma of the hepatoid glands) are frequently reported in veterinary literature. They are locally aggressive tumors with a low tendency to metastatic spread. An hormonal ethiology has been identified for the development of perianal adenomas in male dogs, while the carcinomas are free from hormonal influence. Standard treatments include surgery, cryotherapy or, in selected cases, radiation therapy. In this article we describe the outcome of a small cohort of canine patients with perianal tumors treated with bleomycin selectively driven by trains of biphasic pulses (electrochemotherapy). Twelve canine patients, eight with adenoma and four with carcinoma of the perianal glands, entered the study and received two sessions of ECT under sedation. The pets had local injection of bleomycin at the concentration of 1.5 mg/mg and five minutes after the chemotherapy, trains of 8 biphasic electric pulses lasting 50 + 50 ÎĽs each, with 1 ms interpulse intervals, were delivered by means of modified caliper and needle array electrodes or, for difficult districts, through paired needle electrode. The overall response rate was 91% with a 83% of complete response (10/12); one dog had a PR that lasted 12 months and another had progressive disease. Electrochemotherapy appears as a safe and efficacious modality for the treatment of perianal tumors and warrants further investigations
Ganglioneuroblastoma in a cat: A rare neoplasm treated with electrochemotherapy
An 8-year-old male castrated cat was referred for sudden onset of lameness. Physical examination revealed a 1 × 2 × 1 cm mass originating from a footpad of the right hind leg. A diagnosis of ganglioneuroblastoma was suggested by the tumour appearance following histopathological staining with haematoxylin and eosin and haematoxylin/van Gieson. Immunohistochemical staining for glial fibrillary acidic protein (GFAP), vimentin, neuron-specific enolase (NSE), neurofilament and S100 further confirmed the diagnosis. The staging process did not indicate metastatic spread. The cat was treated with three sessions of electrochemotherapy (ECT) 1 week apart, following local injection of bleomycin. The tumour had completely regressed within 1 week of the third ECT application and remained in remission for 402 days at which time a small recurrence was noted. The animal was given a further session of ECT using intra-lesional cisplatin and again went into remission. It remained tumour free at 450 days. Electrochemotherapy is considered a safe and effective treatment for localised neoplasms of cats and dogs and warrants further investigation. © 2007 Elsevier Ltd. All rights reserved
Electrochemotherapy treatment for bilateral pleomorphic rhabdomyosarcoma in a cat
A 13-year-old male neutered cat was presented for the sudden growth of two nodular lesions close to the upper eyelid of both eyes. Fine-needle aspiration cytology was suggestive of mesenchymal neoplasia. The cat had conservative surgical excision in order to preserve the eyelids' functionality; however, the histopathological report came with a diagnosis of incompletely excised bilateral pleomorphic rhabdomyosarcoma. Due to the local aggressiveness of this neoplasm, the cat was treated with two sessions of cisplatin-based electrochemotherapy, delivered 14 days apart. Systemic or local toxicities were not detected during the whole course of therapy. The cat is still in complete remission after 12 months. Electrochemotherapy is a safe and efficacious adjuvant therapy for aggressive sarcomas and warrants further investigations in order to standardise its protocols. © 2010 British Small Animal Veterinary Association