10 research outputs found

    Internal fixation treatments for intertrochanteric fracture: A systematic review and meta-Analysis of randomized evidence

    Get PDF
    The relative effects of internal fixation strategies for intertrochanteric fracture after operation remain uncertain. We conducted a systematic review and meta-Analysis of randomized controlled trials (RCTs) to address this important issue. We searched PubMed, EMBASE and CENTRAL for RCTs that compared different internal fixation implants in patients with intertrochanteric fracture at 6-month follow-up or longer. We ultimately included 43 trials enrolling 6911 patients; most trials were small in sample sizes and events. Their risk of bias was generally unclear due to insufficient reporting. Because of these, no statistically significant differences were present from most of the comparisons across all the outcomes, and no definitive conclusions can be made. However, a number of trials compared two commonly used internal fixation strategies, gamma nail (GN) and sliding hip screw (SHS). There is good evidence suggesting that, compared to SHS, GN may increase the risk of cut out (OR = 1.87, 95% CI, 1.08 to 3.21), re-operation (OR = 1.61, 95% CI, 1.02 to 2.53), intra-operative (OR = 3.14, 95% CI, 1.34 to 7.35) and later fractures (OR = 3.67, 95% CI, 1.37 to 9.83). Future randomized trials or observational studies that are carefully designed and conducted are warranted to establish the effects of alternative internal fixation strategies for intertrochanteric fracture

    An evolution in the management of fractures of the ankle: safety and efficacy of posteromedial approach for Haraguchi type 2 posterior malleolar fractures.

    No full text
    There has been an evolution recently in the management of unstable fractures of the ankle with a trend towards direct fixation of a posterior malleolar fragment. Within these fractures, Haraguchi type 2 fractures extend medially and often cannot be fixed using a standard posterolateral approach. Our aim was to describe the posteromedial approach to address these fractures and to assess its efficacy and safety

    Unusual insidious spinal accessory nerve palsy: A case report

    No full text
    Introduction. Isolated spinal accessory nerve dysfunction has a major detrimental impact on the functional performance of the shoulder girdle, and is a well-documented complication of surgical procedures in the posterior triangle of the neck. To the best of our knowledge, the natural course and the most effective way of handling spontaneous spinal accessory nerve palsy has been described in only a few instances in the literature. Case presentation. We report the case of a 36-year-old Caucasian, Greek man with spontaneous unilateral trapezius palsy with an insidious course. To the best of our knowledge, few such cases have been documented in the literature. The unusual clinical presentation and functional performance mismatch with the imaging findings were also observed. Our patient showed a deterioration that was different from the usual course of this pathology, with an early onset of irreversible trapezius muscle dysfunction two months after the first clinical signs started to manifest. A surgical reconstruction was proposed as the most efficient treatment, but our patient declined this. Although he failed to recover fully after conservative treatment for eight months, he regained moderate function and is currently virtually pain-free. Conclusion. Clinicians have to be aware that due to anatomical variation and the potential for compensation by the levator scapulae, the clinical consequences of any injury to the spinal accessory nerve may vary. © 2010 Charopoulos et al; licensee BioMed Central Ltd

    Prospective randomised controlled trial of an intramedullary nail versus a sliding hip screw for intertrochanteric fractures of the femur

    No full text
    Purpose: The purpose of this prospective randomised trial was to assess whether an intramedullary nail is superior to a sliding hip screw in the treatment of multifragmentary intertrochanteric fractures Methods: Eighty patients with a 31-A2.2 or A2.3 Arbeitsgemeinschaft für Osteosynthesefragen/Orthopaedic Trauma Association (AO/OTA) intertrochanteric fracture were randomly allocated to fixation with either the Gamma nail or the AMBI sliding hip screw device. Results: All patients were followed up at one, three, six and 12 months postoperatively, except for nine who died. There was no statistical difference in Parker mobility score between groups. The Gamma nail group had significantly higher Barthel Index and EuroQol-5D (EQ-5D) scores than the AMBI group at 12 months. At the same time, the EQ-5D score had returned to its pre-operative values in the Gamma nail group but not in the AMBI group. There were no differences in mortality, radiation time and hospital stay. Duration of the operation, incision length and hip pain occurrence were significantly less in the Gamma nail group. Conclusions: Few failures occur when unstable 31-A2.2 and A2.3 AO/OTA fractures are fixed with a sliding hip screw. Nevertheless, an intramedullary nail seems superior in reconstituting patients to their pre-operative state. © 2013 Springer-Verlag Berlin Heidelberg

    The tip-apex distance in the X-Bolt dynamic plating system

    Get PDF
    The Sliding Hip Screw (SHS) is commonly used to treat trochanteric hip fractures. Fixation failure is a devastating complication requiring complex revision surgery. One mode of fixation failure is lag screw cut-out which is greatest in unstable fracture patterns and when the tip-apex distance of the lag screw is > 25 mm. The X-Bolt Dynamic Hip Plating System (X-Bolt Orthopaedics, Dublin, Ireland) is a new device which aims to reduce this risk of cut-out. However, some surgeons have reported difficulty minimising the tip-apex distance with subsequent concerns that this may lead to an increased risk of cut-out.We measured the tip-apex distance from the intra-operative radiographs of 93 unstable trochanteric hip fractures enrolled in a randomised controlled trial (Warwick Hip Trauma Evaluation, WHiTE One trial). Participants were treated with either the sliding hip screw or the X-Bolt dynamic hip plating system. We also recorded the incidence of cut-out in both groups, at a median follow-up time of 17 months.There was a significantly increased tip-apex distance with the use of the X-Bolt (mean difference 3.7mm (95% confidence interval 1.58 to 5.73); SHS mean 17.1 mm, X-Bolt mean 20.8; p = 0.001. However, this was not associated with an increased incidence of cut-out at a median follow-up time of 17 months, with three cut-outs (6%) in the SHS group and 0 (0%) in the X-Bolt group.The X-Bolt is a safe implant with no increased risk for cut-out. Concerns about minimising the tip-apex distance may be justified but do not appear to be clinically important
    corecore